The Copper Conductors Type 0.6 Kv Electrical Cable 16 Sq mm 300mm
Product Description
The copper conductors type 0.6 KV electrical Cable 16 sq mm 300mm
Application:
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Construction:
Conductor: | annealed copper or of plain aluminium or aluminium alloy | |
Insulation: | XLPE / PVC material | |
Armour: |
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request. | |
Sheath: | PVC compound | |
sheath colour: | black |
Technical data:
Temperature range: | |
during installation: | -5 °C up to +50 °C |
fixed installed: | -30 °C up to +70 °C |
at short circuit of max. 5 s: | up to 160 °C |
Nominal voltage: | Uο/U = 0,6/1 kV |
Test voltage: | 4 kV |
Max. operating voltage in three-phase systems: | 1,2 kV |
Maximal tensile strength: | 50 N/mm² |
Behaviour in fire: | IEC 60332-1 |
Minimal inner bending radius: | |
single core: | 15D |
multi core: | 12D |
Dimensions:
Single core(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
---|---|---|---|---|
mm^2 | mm | mm | mm | mm |
1×1.5 | 1.4 | 0.7 | 1.4 | 5.6 |
1×2.5 | 1.8 | 0.7 | 1.4 | 6.0 |
1×4 | 2.3 | 0.7 | 1.4 | 6.5 |
1×6 | 2.8 | 0.7 | 1.4 | 7.0 |
1×10 | 3.6 | 0.7 | 1.4 | 7.8 |
1×16 | 4.5 | 0.7 | 1.4 | 8.7 |
1×25 | 5.6 | 0.9 | 1.4 | 10.2 |
1×35 | 6.7 | 0.9 | 1.4 | 11.3 |
1×50 | 8.0 | 1 | 1.4 | 12.8 |
1×70 | 9.4 | 1.1 | 1.4 | 14.4 |
1×95 | 11.0 | 1.1 | 1.5 | 16.1 |
1×120 | 12.4 | 1.2 | 1.5 | 17.8 |
1×150 | 13.8 | 1.4 | 1.6 | 19.8 |
1×185 | 15.3 | 1.6 | 1.6 | 21.8 |
1×240 | 17.5 | 1.7 | 1.7 | 24.4 |
1×300 | 19.5 | 1.8 | 1.8 | 26.7 |
1×400 | 22.6 | 2 | 1.9 | 30.5 |
1×500 | 25.2 | 2.2 | 2.0 | 33.7 |
1×630 | 28.3 | 2.4 | 2.2 | 37.4 |
1×800 | 31.9 | 2.6 | 2.3 | 41.7 |
1×1000 | 35.7 | 2.8 | 2.4 | 46.2 |
Two cores(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
---|---|---|---|---|
mm^2 | mm | mm | mm | mm |
2×1.5 | 1.4 | 0.7 | 1.8 | 9.2 |
2×2.5 | 1.8 | 0.7 | 1.8 | 10.0 |
2×4 | 2.3 | 0.7 | 1.8 | 11.0 |
2×6 | 2.8 | 0.7 | 1.8 | 12.0 |
2×10 | 3.6 | 0.7 | 1.8 | 13.6 |
2×16 | 4.5 | 0.7 | 1.8 | 15.4 |
2×25 | 5.6 | 0.9 | 1.8 | 18.4 |
2×35 | 6.7 | 0.9 | 1.8 | 20.6 |
2×50 | 8.0 | 1 | 1.8 | 23.6 |
2×70 | 9.4 | 1.1 | 1.8 | 26.8 |
2×95 | 11.0 | 1.1 | 1.9 | 30.2 |
2×120 | 12.4 | 1.2 | 2.0 | 33.7 |
2×150 | 13.8 | 1.4 | 2.2 | 37.5 |
2×185 | 15.3 | 1.6 | 2.3 | 41.6 |
2×240 | 17.5 | 1.7 | 2.5 | 46.7 |
2×300 | 19.5 | 1.8 | 2.6 | 51.4 |
2×400 | 22.6 | 2 | 2.9 | 58.9 |
Three cores(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
---|---|---|---|---|
mm^2 | mm | mm | mm | mm |
3×1.5 | 1.4 | 0.7 | 1.8 | 9.6 |
3×2.5 | 1.8 | 0.7 | 1.8 | 10.5 |
3×4 | 2.3 | 0.7 | 1.8 | 11.6 |
3×6 | 2.8 | 0.7 | 1.8 | 12.6 |
3×10 | 3.6 | 0.7 | 1.8 | 14.4 |
3×16 | 4.5 | 0.7 | 1.8 | 16.3 |
3×25 | 5.6 | 0.9 | 1.8 | 19.5 |
3×35 | 6.7 | 0.9 | 1.8 | 21.9 |
3×50 | 8.0 | 1 | 1.8 | 25.1 |
3×70 | 9.4 | 1.1 | 1.9 | 28.7 |
3×95 | 11.0 | 1.1 | 2.0 | 32.4 |
3×120 | 12.4 | 1.2 | 2.1 | 36.1 |
3×150 | 13.8 | 1.4 | 2.3 | 40.3 |
3×185 | 15.3 | 1.6 | 2.4 | 44.6 |
3×240 | 17.5 | 1.7 | 2.6 | 50.2 |
3×300 | 19.5 | 1.8 | 2.7 | 55.2 |
3×400 | 22.6 | 2 | 3.0 | 63.3 |
Three cores+1(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) | ||
---|---|---|---|---|---|---|
mm^2 | (3)mm | (1)mm | (3)mm | (1)mm | mm | mm |
3x 16/10 | 4.5 | 3.6 | 0.7 | 0.7 | 1.8 | 17.5 |
3x 25/16 | 5.6 | 4.5 | 0.9 | 0.7 | 1.8 | 21.2 |
3x 35/16 | 6.7 | 4.5 | 0.9 | 0.7 | 1.8 | 23.8 |
3x 50/25 | 8 | 5.6 | 1 | 0.9 | 1.8 | 27.5 |
3x 70/35 | 9.4 | 6.7 | 1.1 | 0.9 | 2.0 | 31.7 |
3x 95/50 | 11 | 8 | 1.1 | 1 | 2.1 | 35.8 |
3×120/70 | 12.4 | 9.4 | 1.2 | 1.1 | 2.3 | 39.9 |
3×150/70 | 13.8 | 9.4 | 1.4 | 1.1 | 2.4 | 44.6 |
3×185/95 | 15.3 | 11 | 1.6 | 1.1 | 2.6 | 49.5 |
3×240/120 | 17.5 | 12.4 | 1.7 | 1.2 | 2.8 | 55.7 |
3×300/150 | 19.5 | 13.8 | 1.8 | 1.4 | 3.0 | 61.4 |
3×400/185 | 22.6 | 15.3 | 2 | 1.6 | 3.2 | 70.4 |
Four cores(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
---|---|---|---|---|
mm^2 | mm | mm | mm | mm |
4×1.5 | 1.4 | 0.7 | 1.8 | 10.4 |
4×2.5 | 1.8 | 0.7 | 1.8 | 11.3 |
4×4 | 2.3 | 0.7 | 1.8 | 12.5 |
4×6 | 2.8 | 0.7 | 1.8 | 13.7 |
4×10 | 3.6 | 0.7 | 1.8 | 15.7 |
4×16 | 4.5 | 0.7 | 1.8 | 17.8 |
4×25 | 5.6 | 0.9 | 1.8 | 21.5 |
4×35 | 6.7 | 0.9 | 1.8 | 24.1 |
4×50 | 8.0 | 1 | 1.8 | 27.8 |
4×70 | 9.4 | 1.1 | 2.0 | 32.0 |
4×95 | 11.0 | 1.1 | 2.1 | 36.1 |
4×120 | 12.4 | 1.2 | 2.3 | 40.2 |
4×150 | 13.8 | 1.4 | 2.4 | 44.9 |
4×185 | 15.3 | 1.6 | 2.6 | 49.8 |
4×240 | 17.5 | 1.7 | 2.8 | 56.0 |
4×300 | 19.5 | 1.8 | 3.0 | 61.7 |
4×400 | 22.6 | 2 | 3.2 | 70.7 |
Multi-cores(unarmoured)
Nominal Cross Section | Diameter of Conductor (Approx.) | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter (Approx.) |
---|---|---|---|---|
mm^2 | mm | mm | mm | mm |
5×1.5 | 1.4 | 0.7 | 1.8 | 11.2 |
7×1.5 | 1.4 | 0.7 | 1.8 | 12.0 |
10×1.5 | 1.4 | 0.7 | 1.8 | 14.8 |
12×1.5 | 1.4 | 0.7 | 1.8 | 15.2 |
14×1.5 | 1.4 | 0.7 | 1.8 | 16.0 |
19×1.5 | 1.4 | 0.7 | 1.8 | 17.6 |
21×1.5 | 1.4 | 0.7 | 1.8 | 18.4 |
24×1.5 | 1.4 | 0.7 | 1.8 | 20.4 |
30×1.5 | 1.4 | 0.7 | 1.8 | 21.6 |
40×1.5 | 1.4 | 0.7 | 1.8 | 26.0 |
48×1.5 | 1.4 | 0.7 | 1.8 | 26.4 |
61×1.5 | 1.4 | 0.7 | 1.9 | 29.0 |
5×2.5 | 1.8 | 0.7 | 1.8 | 12.2 |
7×2.5 | 1.8 | 0.7 | 1.8 | 13.2 |
10×2.5 | 1.8 | 0.7 | 1.8 | 16.4 |
12×2.5 | 1.8 | 0.7 | 1.8 | 16.9 |
14×2.5 | 1.8 | 0.7 | 1.8 | 17.7 |
19×2.5 | 1.8 | 0.7 | 1.8 | 19.6 |
21×2.5 | 1.8 | 0.7 | 1.8 | 20.6 |
24×2.5 | 1.8 | 0.7 | 1.8 | 22.8 |
30×2.5 | 1.8 | 0.7 | 1.8 | 24.1 |
40×2.5 | 1.8 | 0.7 | 1.9 | 29.4 |
48×2.5 | 1.8 | 0.7 | 1.9 | 29.9 |
61×2.5 | 1.8 | 0.7 | 2.0 | 32.8 |
*) Packing: CUT = cable in different lengths on drum or reel, possible cutting at required length.
COMPANY INFORMATION:
For more information and inquiry, pls contact me without any hesitation.
- Next: The Copper PE Insulated Ttu-0.6 Kv Electrical Cable 300 Mcm 500 Mcm 250 Mcm
- Previous: NEMA-Wc-5 Copper PVC Insulated Thw Building House Electric Wire 6 4 2 AWG
Contact us
Similar Or Related
-
15kV 3 Core 4/0AWG Aluminum Conductor XLPE Insulated SWA Armored MV Power Cable
-
15kV 1 Core 500 MCM Aluminimum Conductor XLPE Insulated Power Cable AWA Armored Wire Armoured
-
70mm2 6.35/11kV 3 Core XLPE Insulated Cu SWA Armored Electric Cable IEC 60502-2
-
Electric XLPE Power Cable 11kV PILC Cu 3 Core 120mm2 Armoured IEC 60502-2
-
The Copper Conductors Type 0.6 Kv Electrical Cable 16 Sq mm 300mm