Single Core 0.6/1kv Copper Core PVC Insulation Overhead Cable

Single Core 0.6/1kv Copper Core PVC Insulation Overhead Cable

Single Core 0.6/1kv Copper Core PVC Insulation Overhead Cable

JKV-0.6/. 1

Jinyuan

ISO9001, CE, UL, CCC

Overhead

Round Wire

PVC

No

Copper

Overhead

Stranded

Insulated

Accord with The Request

5~15 Official Days

100000m2

20 Years

Jinyuan

Wooden Drum

Copper

China

8544492100

Product Description

single core 0.6/1kV Copper core PVC insulation overhead cable 

1.Executive Standard  GB/T12527-2008

2.Application:
    This product is suitable for copper core,alumininum core or alumininum alloy core weatherproof PVC,PE and XLPE insulated overhead cable under AC rated voltage of 1KV in overgead power line.

3.Condition Of Usage
-The rated voltage U0/U0.6/1kV
-Admissible long-term operating temperature for conductor of cable For PVC and PE insulated ,not exceed 70ºC. For XLPE insulation ,not eceed 90 ºC.
-The temperature should not less than -20ºC during laying cable.
-Admissible bending radius:
 For O.D.<25mm,the bending radius should not less than 4D.
 For O.D.≥25mm,should not less than 6D.

4.Meaning Of Alphabets In Type
 JK—-refer to overhead         LH—-alumininum alloy
 YJ—-XLPE insuladed          L—-Alumininum
 Y—-Polyethylene insulation
 

Type Description Main Usage
JKV-0.6/1 Rated voltage 0.6/1kV Cu core PVC insulation overhead cable Aerial fixed laying outgoing line etc
JKLV-0.6/1 Rated voltage 0.6/1kV Al core PVC insulation overhead cable
JKLHV-0.6/1 Rated voltage 0.6/1kV alloy core PVC insulation overhead cable
JKY-0.6/1 Rated voltage 0.6/1kV Cu core PE insulation overhead cable
JKLY-0.6/1 Rated voltage 0.6/1kV Al core PE insulation overhead cable
JKLHY-0.6/1 Rated voltage 0.6/1kV AL alloy core PE insulation overhead cable
JKYJ-0.6/1 Rated voltage 0.6/1kV Cu core XLPE insulation overhead cable
JKLYJ-0.6/1 Rated voltage 0.6/1kV Al core XLPE insulation overhead cable
JKLHYJ-0.6/1 Rated voltage 0.6/1kV AL alloy core XLPE insulation overhead cable
Nominal Cross Section mm2 The Resistance 20ºC≤Ohm/km  At Rated Work temperture the Lowest Insulation Resistance MΩ.km Cable Drawing pressure ≥N
Cu Core Al Core Al alloy Core
Hard Cu Soft Cu 70ºC 90ºC Hard Cu Core Al Core Al alloy Core
10 1.906  1.83 3.08 3.574 0.0067 0.0067 3471 1650 2514
16 1.198  1.15 1.91 2.217 0.0065 0.0065 5486 2512 4022
25 0.749  0.727 1.20  1.393 0.0054 0.0054 8465 3762 6284
35 0.54  0.524 0.868 1.007 0.0054 0.0054 11731 5177 8800
50 0.399  0.387 0.641 0.744 0.0046 0.0046 16502 7011 12569
70 0.276  0.268 0.443 0.514 0.0040  0.0040  23461 10354 17596
95 0.199  0.193 0.320  0.371 0.0039 0.0039 31759 13727 23880
120 0.158  0.153 0.253 0.294 0.0035 0.0035 39911 17339 30164
150 0.128  0.124 0.206 0.239 0.0035 0.0035 49505 21033 37706
185 0.1021  0.0991 0.164 0.19 0.0035 0.0035 61846 26732 46503
240 0.0777  0.0754 0.125 0.145 0.0034 0.0034 79823 34679 60329
300 0.100  0.116 0.0033 0.0033 43349 75411
400 0.0778 0.0904 0.0032 0.0032 55707 100548

Structure And Weight Of Rated Voltage 1kV Single Core Overhead Cables

No. Core ×Nominal Cross Section mm2 Calculating Diameter of Cable mm Calculating Weight
JKV JKLV JKY JKLY JKYJ JKLYJ
1 1×16 8.0 189.3 80.2 163.3 68.1 163.3 68.1
2 1×25 9.4 278.9 112.3 274.4 107.1 274.4 107.1
3 1×35 11.0 393.6 157 371.2 142.4 371.2 142.4
4 1×50 12.3 537.2 207.4 501.7 193.1 5011.7 193.1
5 1×70 14.1 753.2 280.2 708.9 259.7 708.9 259.7
6 1×95 16.5 1018.6 378.4 958.2 349.1 958.2 349.1
7 1×120 18.1 1226.1 464.4 1180.8 420.8 1180.8 420.8
8 1×150 20.2 1299.8 482.1 1464.8 522.1 1464.8 522.1
9 1×185 22.5 1996.4 720 1816.8 647 1816.8 647
10 1×240 25.6 2803.2 936.8 2375.5 848.1 2375.5 848.1