PVC Sheathed Flexible Control Cable, XLPE Insulated Copper Conductor Power Cable
Product Description
Type and Name
Type | Name |
KVV | Copper conductor PVC insulated PVC sheathed control cable |
KVVP2 | Copper conductor PVC insulated PVC sheathed copper tape screened control cable |
KVV22 | Copper conductor PVC insulated PVC sheathed steel tape armored control cable |
KVVP2-22 | Copper conductor PVC insulated PVC sheathed copper tape screened, steel tape armored control cable |
KVVR | Copper conductor PVC insulated PVC sheathed control flexible cable |
KVV32 | Copper conductor PVC insulated PVC sheathed steel wire armored control cable |
KVVP2-32 | Copper conductor PVC insulated PVC sheathed copper tape screened steel wire armored control cable |
KYJV | Copper conductor XLPE insulated PVC sheathed control cable |
KYJVP2 | Copper conductor XLPE insulated PVC sheathed copper tape screened control cable |
KYJV22 | Copper conductor XLPE insulated PVC sheathed steel tape armored control cable |
KYJVP2-22 | Copper conductor XLPE insulated PVC sheathed copper tape screened steel tape armored control cable |
KYJV32 | Copper conductor XLPE insulated PVC sheathed steel wire armored control cable |
KYJVP2-32 | Copper conductor XLPE insulated PVC sheathed copper tape screened steel wire armored control cable |
Construction Sketch
4.Wrapping tape
5.Copper tape screen
6.Sheath
7.Extruded or lapped bedding
8.Double steel tape armour
Standards
It is manufactured in accordance with GB/T9330-2008, and the factory can also manufacture the cables in accordance with other standards such as IEC, BS, DIN, etc.
Characteristics and Applications
Plastic insulated control cable are used for connecting electrical equipments. It applies to controlling, monitoring and protective system with A.C. rated voltage U0/U up to and including 450/750V.
The main features of the flame retardant PVC control cable is hard to get fire or that the continuous burning of cables is very limited when it is on fire. It applies to the places with special demands of flame retardant property.
Fire-resistance cable can operate normally for some time when it is burning except that it can transmit electrical power under normal condition. It is used in the places necessary to resist fire.
Main Technical Parameter
KVV, ZC-KVV
Number of cores x Nominal cross-section mm2 |
Kind of conductor |
Reference outside diameter of cable mm |
Reference weight of cable kg/km |
Max.D.C. resistance at 20ºC Ω/km |
Min.insulation resistance at 70ºC MΩ·km |
2 x 0.75 | 1 | 7.2 | 61 | 24.5 | 0.012 |
2 x 0.75 | 2 | 7.5 | 65 | 24.5 | 0.014 |
2 x 2.5 | 1 | 9.6 | 124 | 7.41 | 0.01 |
2 x 2.5 | 2 | 10.2 | 135 | 7.41 | 0.01 |
2 x 10 | 2 | 15.7 | 377 | 1.83 | 0.0065 |
5 x 0.75 | 1 | 8.7 | 101 | 24.5 | 0.012 |
5 x 0.75 | 2 | 9.1 | 108 | 24.5 | 0.014 |
5 x 2.5 | 1 | 12.7 | 247 | 7.41 | 0.01 |
5 x 2.5 | 2 | 13.4 | 267 | 7.41 | 0.01 |
5 x 10 | 2 | 20.4 | 769 | 1.83 | 0.0065 |
10 x 0.75 | 1 | 11.6 | 176 | 24.5 | 0.012 |
10 x 0.75 | 2 | 12.2 | 189 | 24.5 | 0.014 |
10 x 2.5 | 1 | 17.2 | 447 | 7.41 | 0.01 |
10 x 2.5 | 2 | 18.2 | 483 | 7.41 | 0.01 |
10 x 10 | 2 | 28.4 | 1452 | 1.83 | 0.0065 |
30 x 0.75 | 1 | 17.6 | 450 | 24.5 | 0.012 |
30 x 0.75 | 2 | 18.6 | 483 | 24.5 | 0.014 |
30 x 2.5 | 1 | 26 | 1167 | 7.41 | 0.01 |
30 x 2.5 | 2 | 27.6 | 1262 | 7.41 | 0.01 |
61 x 0.75 | 1 | 23.8 | 857 | 24.5 | 0.012 |
61 x 0.75 | 2 | 25.1 | 906 | 24.5 | 0.014 |
61 x 2.5 | 1 | 36 | 2320 | 7.41 | 0.01 |
61 x 2.5 | 2 | 38.3 | 2509 | 7.41 | 0.01 |
Our company