PVC Insulated Copper Wire (BVR) Building Wire
Product Description
Construction :
a wide range of copper and aluminum building wires and cables to meet today’s construction wiring challenges. Designed for wet or dry locations, building wire can be armoured or non-armoured. Most building wire has a maximum voltage rating of 600V, although 1000V building wire is also available.
Building Wire Applications
Building wire is used to carry electricity into or within buildings and structures, and can be employed for a variety of commercial and residential applications – including electrical wiring systems, power generators, motors and electrical lights. ACWU and NMWU, in particular, are well-suited for direct earth burial and wiring in hazardous locations. Stranded copper wire is often used for overhead electrical transmission and distribution, and for grounding electrical systems where high conductivity and flexibility is required.
450/750V PVC Insulated (Non-Sheathed) Cables to BS 6004
Reference No 6491X
Single Core PVC Insulated
Size of conductor | Nominal thickness of insulation
mm |
Mean overall diameter Upper limit mm |
Approx. net weight per km
kg |
|
Nominal cross-sectional area mm2 |
Number and diameter of wires no./mm |
|||
1.0 | 1/1.13 | 0.6 | 2.8 | 14 |
1.5 | 1/1.38 | 0.7 | 3.3 | 20 |
1.5 | 7/0.50 | 0.7 | 3.4 | 20 |
2.5 | 1/1.78 | 0.8 | 3.9 | 33 |
2.5 | 7/0.67 | 0.8 | 4.2 | 34 |
4 | 1/2.25 | 0.8 | 4.4 | 51 |
4 | 7/0.85 | 0.8 | 4.8 | 51 |
6 | 1/2.76 | 0.8 | 4.9 | 67 |
6 | 7/1.04 | 0.8 | 5.4 | 71 |
10 | 1/3.57 | 1.0 | 6.4 | 110 |
10 | 7/1.35 | 1.0 | 6.8 | 120 |
16 | 1/4.50 | 1.0 | 7.3 | 170 |
16 | 7/1.70 | 1.0 | 8.0 | 180 |
25 | 7/2.14 | 1.2 | 9.8 | 285 |
35 | 19/1.53 | 1.2 | 11.0 | 380 |
50 | 19/1.78 | 1.4 | 13.0 | 510 |
70 | 19/2.14 | 1.4 | 15.0 | 715 |
95 | 19/2.52 | 1.6 | 17.0 | 990 |
120 | 37/2.03 | 1.6 | 19.0 | 1230 |
150 | 37/2.25 | 1.8 | 21.0 | 1510 |
185 | 37/2.52 | 2.0 | 23.5 | 1900 |
240 | 61/2.25 | 2.2 | 26.5 | 2490 |
300 | 61/2.52 | 2.4 | 29.5 | 3050 |
400 | 61/2.85 | 2.6 | 33.5 | 3900 |
500 | 61/3.20 | 2.8 | 37.0 | 4880 |
Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.
2.Colors of standard: red, black, blue, white,brown, grey, green, yellow,
450/750V PVC Insulated (Non-Sheathed) Flexible Conductor General Purpose Cables to BS 6004
Harmonized Code
Designation H07V-K
Single Core PVC Insulated
Size of conductor | Nominal thickness of insulation
mm |
Mean overall diameter
Upper limit mm |
Approx.net weight per km
kg |
|
Nominal cross-sectional area mm2 |
Number and diameter of wires no./mm |
|||
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5 | 30/0.25 | 0.7 | 3.5 | 21 |
2.5 | 50/0.25 | 0.8 | 4.2 | 33 |
4 | 56/0.30 | 0.8 | 4.8 | 50 |
6 | 84/0.30 | 0.8 | 6.3 | 70 |
10 | 80/0.40 | 1.0 | 7.6 | 120 |
16 | 126/0.40 | 1.0 | 8.8 | 175 |
25 | 196/0.40 | 1.2 | 11.0 | 290 |
35 | 276/0.40 | 1.2 | 12.5 | 400 |
50 | 396/0.40 | 1.4 | 14.5 | 565 |
70 | 360/0.50 | 1.4 | 17.0 | 770 |
95 | 475/0.50 | 1.6 | 19.0 | 1010 |
120 | 608/0.50 | 1.6 | 21.0 | 1260 |
150 | 756/0.50 | 1.8 | 23.5 | 1580 |
185 | 925/0.50 | 2.0 | 26.0 | 1900 |
240 | 1221/0.50 | 2.2 | 29.5 | 2500 |
Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.
2.Colors of standard: red, black, brown, grey,orange, white, violet, pink, green/yellow, yellow
300/500V PVC Insulated PVC Sheathed Cables to BS 6004
Reference No 6181y
Single Core PVC Insulated and PVC Sheathed
Size of conductor | Nominal thickness of insulation
mm |
Nominal thickness of sheath mm |
Mean overall diameter | Approx.net weight per km
kg |
||
Nominal cross-sectional area mm2 |
Number and diameter of wires mm |
Lower limit
mm |
Upper limit
mm |
|||
1.0 | 1/1.13 | 0.6 | 0.8 | 3.8 | 4.5 | 28 |
1.5 | 1/1.38 | 0.7 | 0.8 | 4.2 | 4.9 | 35 |
2.5 | 1/1.78 | 0.8 | 0.8 | 4.8 | 5.8 | 50 |
4 | 7/0.85 | 0.8 | 0.9 | 5.4 | 6.8 | 75 |
6 | 7/1.04 | 0.8 | 0.9 | 6.0 | 7.4 | 100 |
10 | 7/1.35 | 1.0 | 0.9 | 7.2 | 8.8 | 155 |
16 | 7/1.70 | 1.0 | 1.0 | 8.4 | 10.5 | 225 |
25 | 7/2.14 | 1.2 | 1.1 | 10.0 | 12.5 | 340 |
35 | 19/1.53 | 1.2 | 1.1 | 11.0 | 13.5 | 445 |
Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound.
2.Core colors: red, black.Sheath colour: grey or white.
Reference No 6192y
Flat Twin
Size of conductor | Nominal thickness of insulation
mm |
Nominal thickness of sheath mm |
Mean overall dimensions |
Approx. net weight per km
kg |
||
Nominal cross-sectional area mm2 |
Number and diameter of wires mm |
Lower limit
mm |
Upper limit
mm |
|||
1.0 | 1/1.13 | 0.6 | 0.9 | 4.0*6.2 | 4.7*7.4 | 55 |
1.5 | 1/1.38 | 0.7 | 0.9 | 4.4*7.0 | 5.4*8.4 | 70 |
2.5 | 1/1.78 | 0.8 | 1.0 | 5.2*8.4 | 6.2*9.8 | 105 |
4 | 7/0.85 | 0.8 | 1.0 | 5.6*9.6 | 7.2*11.5 | 150 |
6 | 7/1.04 | 0.8 | 1.1 | 6.4*10.5 | 8.0*13.0 | 205 |
10 | 7/1.35 | 1.0 | 1.2 | 7.8*13.0 | 9.6*16.0 | 325 |
16 | 7/1.70 | 1.0 | 1.3 | 9.0*15.5 | 11.0*18.5 | 465 |
Notes
1.Conductor of high conductivity copper,wires insulated with PVC compound.sheathed with PVC compound.
2.Color of sheath:grey or white,
300/500V PVC Insulated PVC Sheathed Cables to BS 6004
Reference No 6193y
Three Core (Flat)
Size of conductor | Nominal thickness of insulation mm |
Nominal thickness of sheath mm |
Mean overall diameter | Approx. net weight per km
kg |
||
Nominal cross-sectional area mm2 |
Number and diameter of wires mm |
Lower limit
mm |
Upper limit
mm |
|||
1.0 | 1/1.13 | 0.6 | 0.9 | 4.0*8.4 | 4.7*9.8 | 77 |
1.5 | 1/1.38 | 0.7 | 0.9 | 4.4*9.8 | 5.4*11.5 | 100 |
2.5 | 1/1.78 | 0.8 | 1.0 | 5.2*11.5 | 6.2*13.5 | 150 |
4 | 7/0.85 | 0.8 | 1.1 | 5.8*13.5 | 7.4*16.5 | 230 |
6 | 7/1.04 | 0.8 | 1.1 | 6.4*15.0 | 8.0*18.0 | 300 |
10 | 7/1.35 | 1.0 | 1.2 | 7.8*19.0 | 9.6*22.5 | 485 |
16 | 7/1.70 | 1.0 | 1.3 | 9.0*22.0 | 11.0*26.5 | 700 |
Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.Sheathed with PVC compound.
2.Core colors: red, yellow and blue,(yellow in centre) Sheath colors: grey or white.
Reference No 6242y
Flat-Twin with Bare Earth-continuity Conductor
Size of conductor | Nominal thickness of insulation mm |
Size of earth conductivity conductor no./mm |
Nominal thickness of sheath
mm |
Mean overall dimensions | Approx. net weight per km
kg |
||
Nominal cross- sectional area mm2 |
Number and diameter of wires
mm |
Lower limit
mm |
Upper limit
mm |
||||
1.0 | 1/1.13 | 0.6 | 1/1.13 | 0.9 | 4.0*7.2 | 4.7*8.6 | 70 |
1.5 | 1/1.38 | 0.7 | 1/1.13 | 0.9 | 4.4*8.2 | 5.4*9.6 | 85 |
2.5 | 1/1.78 | 0.8 | 1/1.13 | 1.0 | 5.2*9.4 | 6.2*11.0 | 120 |
4 | 7/0.85 | 0.8 | 1/1.38 | 1.0 | 5.6*10.5 | 7.2*13.0 | 175 |
6 | 7/1.04 | 0.8 | 1/1.78 | 1.1 | 6.4*12.5 | 8.0*15.0 | 240 |
10 | 7/1.35 | 1.0 | 7/0.85 | 1.2 | 7.8*15.5 | 9.6*19.0 | 390 |
16 | 7/1.70 | 1.0 | 7/1.04 | 1.3 | 9.0*18 | 11.0*22.0 | 560 |
Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.Sheathed with PVC compound.
2.Core colors: red and black. Sheath colors:grey or white.
300/500V PVC Insulated PVC Sheathed Cables to BS 6004
Reference No 6243y
Three-core (Flat) with Bare
Earth-continuity Conductor
Size of conductor | Nominal thickness of insulation mm |
Size of earth- conduct -ivity conductor No/mm |
Nominal thickness of sheath mm |
Mean overall dimensions | Approx. net weight per km
kg |
||
Nominal cross- sectional area mm2 |
Number and diameter of wires
mm |
Lower limit
mm |
Upper limit mm |
||||
1.0 | 1/1.13 | 0.6 | 1/1.13 | 0.9 | 4.0*9.6 | 4.7*11.0 | 92 |
1.5 | 1/1.38 | 0.7 | 1/1.13 | 0.9 | 4.4*10.5 | 5.4*12.5 | 115 |
2.5 | 1/1.78 | 0.8 | 1/1.13 | 1.0 | 5.2*12.5 | 6.2*14.5 | 170 |
4 | 7/0.85 | 0.8 | 1/1.38 | 1.1 | 5.8*14.5 | 7.4*18.0 | 255 |
6 | 7/1.04 | 0.8 | 1/1.78 | 1.1 | 6.4*16.5 | 8.0*20.0 | 340 |
10 | 7/1.35 | 1.0 | 7/0.85 | 1.2 | 7.8*21.0 | 9.6*25.5 | 550 |
16 | 7/1.70 | 1.0 | 7/1.04 | 1.3 | 9.0*24.5 | 11.0*29.5 | 790 |
Notes
1.Conductor of high conductivity copper wires insulated with PVC compound. Sheathed with PVC compound.
2.Core colors: red, yellow and blue(yellow in centre) Sheath colors: grey or white.
300/300V PVC Insulated Parallel Flexible Cords to BS 6500
Reference No 2812X RVB
Twin Core
Size of conductor | Nominal thickness of insulation mm |
Mean overall dimensions | Approx. net weight per km
kg |
||
Nominal cross-sectional area mm2 |
Number and diameter of wires
no/mm |
Lower Limit mm |
Upper Limit Mm |
||
0.5 | 28/0.15 | 0.8 | 2.5×5.0 | 3.0×6.0 | 24 |
0.75 | 42/0.15 | 0.8 | 2.7×5.4 | 3.2×6.4 | 29 |
Notes
1.Conductors of high conductivity copper wires insulated with PVC compound.
2.One core with a ridge for identification.
300/500V and 450/750V PVC Insulated Flexible Cords to BS 6500/6004
Reference No 2491X
Single Core
Size of conductor | Nominal thickness of insulation mm |
Mean overall diameter
Upper limit mm |
Approx. net weight per km
kg |
|
Nominal cross-sectional area mm2 |
Number and diameter of wire
no/mm |
|||
0.5 | 16/0.20 | 0.6 | 2.6 | 10 |
0.75 | 24/0.20 | 0.6 | 2.8 | 13 |
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5* | 30/0.25 | 0.7 | 3.5 | 20 |
2.5* | 50/0.25 | 0.8 | 4.2 | 32 |
4.0* | 56/0.30 | 0.8 | 4.8 | 49 |
Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.
2.Standard colors: red.black, white, blue,brown, grey and green/yellow.
*:Rating Voltage 450/750V
300/500V PVC Insulated Twisted Twin Flexible Cords to BS 6500
Reference No 2492X
Twisted Twin
Size of conductor | Nominal thickness of insulation mm |
Mean overall diameter of each core Upper limit mm |
Approx. net weight per km
kg |
|
Nominal cross-sectional area mm2 |
Number and diameter of wires mm |
|||
0.5 | 16/0.20 | 0.6 | 4.6 | 20 |
0.75 | 24/0.20 | 0.6 | 5.0 | 26 |
1.0 | 32/0.20 | 0.6 | 5.4 | 33 |
Notes
1.Conductor of high conductivity copper wires insulated with PVC compound.
2.Two cores twisted together.
300/300V PVC Insulated PVC Sheathed Parallel Twin Light Flexible Cords to BS 6500
Reference No 2192Y
Parallel Twin
Size of conductor | Nominal thickness of insulation mm |
Nominal thickness of sheath mm |
Mean overall dimensions | Approx. net weight per km
kg |
||
Nominal cross- sectional area mm2 |
Number and diameter of wires
No./mm |
Upper Limit mm |
Upper Limit mm |
|||
0.5 | 16/0.20 | 0.5 | 0.6 | 3.0×4.8 | 3.6×6.0 | 27 |
0.75 | 24/0.20 | 0.5 | 0.6 | 3.2×5.2 | 3.9×6.4 | 34 |
Notes
1.Conductors of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound.
2.Core colors: blue and brown . Sheathed colors: grey,white or black.
300/300V PVC/PVC Sheathed Circular Light Flexible Cords to BS 6500
Reference No 2182Y
Twin Core
Size of conductor | Nominal thickness of insulation mm |
Nominal thickness of sheath mm |
Mean overall dimensions | Approx. net weight per km
kg |
||
Nominal cross- sectional area mm2 |
Number and diameter of wires No./mm |
Upper Limit mm |
Upper Limit mm |
|||
0.5 | 16/0.20 | 0.5 | 0.6 | 4.8 | 6.0 | 36 |
0.75 | 24/0.20 | 0.5 | 0.6 | 5.2 | 6.4 | 45 |
Notes
1.Conductors of high conductivity copper wires insulated with PVC compound. sheathed with PVC compound.
2.Core colors: blue and brown. Sheathed colors: grey,white or black.
Reference No 2183Y
Three Core
Size of conductor | Nominal thickness of insulation mm |
Nominal thickness of Sheath mm |
Mean overall dimensions | Approx. net weight per km
kg |
||
Nominal cross- sectional area mm2 |
Number and diameter of wires
no/mm |
Lower Limit mm |
Upper Limit mm |
|||
0.5 | 16/0.2 | 0.5 | 0.6 | 5.0 | 6.2 | 44 |
0.75 | 24/0.2 | 0.5 | 0.6 | 5.4 | 6.8 | 55 |
Notes
1.Conductor of high conductivity copper wires insulated with PVC compound. sheathed with PVC compound.
2.Core colors: green/ yellow blue and brown. Sheathed colors: grey,white or black.
300/500V PVC/PVC Sheathed Parallel Twin Flexible Cords to BS 6500
Reference No 3192Y
Parallel Twin
Size of conductor | Nominal thickness of insulation mm |
Nominal thickness of Sheath mm |
Mean overall dimensions | Approx. net weight per km
kg |
||
Nominal cross- sectional area mm2 |
Number and diameter of wires No./mm |
Lower Limit mm |
Upper Limit mm |
|||
0.75 | 24/0.20 | 0.6 | 0.8 | 3.8*6.0 | 5.2*7.6 | 47 |
Notes
1.Conductors of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound.
2.Core colors: blue and brown. Sheathed colors: grey white or black.
300/500VPVC/PVC Sheathed Circular Flexible Cords to BS 6500
Reference No 3182Y
Twin Core
Size of conductor | Nominal thickness of insulation mm |
Nominal thickness of sheath mm |
Mean overall dimensions | Approx. net weight per km
kg |
||
Nominal cross- sectional area mm2 |
Number and diameter of wires
no/mm |
Lower Limit mm |
Upper Limit mm |
|||
0.75 | 24/0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 63 |
1.0 | 32/0.20 | 0.6 | 0.8 | 6.4 | 8.0 | 73 |
1.25 | 40/0.20 | 0.7 | 0.8 | 7.0 | 8.6 | 84 |
1.5 | 30/0.25 | 0.7 | 0.8 | 7.4 | 9.0 | 95 |
2.5 | 50/0.25 | 0.8 | 1.0 | 8.9 | 11.0 | 145 |
Notes
1.Conductors of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound.
2.Core colors: blue and brown. Sheathed colors:grey. white or black.
300/500V PVC/PVC Sheathed Circular Flexible Cords to BS 6500
Reference No 3183Y
Three Core
Size of conductor | Nominal thickness of insulation mm |
Nominal thickness of sheath mm |
Mean overall dimensions | Approx. net weight per km
kg |
||
Nominal cross- sectional area mm2 |
Number and diameter of wires
no/mm |
Lower Limit mm |
Upper Limit mm |
|||
0.75 | 24/0.20 | 0.6 | 0.8 | 6.4 | 8.0 | 74 |
1.0 | 32/0.20 | 0.6 | 0.8 | 6.8 | 8.4 | 86 |
1.25 | 40/0.20 | 0.7 | 0.9 | 7.6 | 9.4 | 104 |
1.5 | 30/0.25 | 0.7 | 0.9 | 8.0 | 9.8 | 120 |
2.5 | 50/0.25 | 0.8 | 1.1 | 9.6 | 12.0 | 180 |
Notes
1.Conductors of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound.
2.Core colors green/yellow, blue and brown. Sheathed colors: grey.white or black.
300/500V PVC/PVC Sheathed Circular Flexible Cords to BS 6500
Reference No 3184Y
Four Core
Size of conductor | Nominal thickness of insulation mm |
Nominal thickness of sheath mm |
Mean overall dimensions | Approx. net weight per km
kg |
||
Nominal cross- sectional area mm2 |
Number and diameter of wires
no/mm |
Lower limit mm |
Upper limit mm |
|||
0.75 | 24/0.20 | 0.6 | 0.8 | 6.8 | 8.6 | 78 |
1.0 | 32/0.20 | 0.6 | 0.9 | 7.6 | 9.4 | 110 |
1. 5 | 30/0.25 | 0.7 | 1.0 | 9.0 | 11.0 | 150 |
2.5 | 50/0.25 | 0.8 | 1.1 | 10.5 | 13.0 | 220 |
Notes
1.Conductors of high conductivity copper wires insulated with PVC compound.sheathed with PVC compound.
2.Core colors green/yellow, black, blue and brown. Sheathed colors: grey. white or black.
Class No 802
Twin Core
Size of conductor | Nominal thickness of insulation mm |
Nominal overall dimension mm |
Approx. net weight per km
kg |
|
Nominal cross-sectional area mm2 |
Number and diameter of wires no/mm |
|||
0. 5 | 16/0.20 | 0.5 | 1.95*3.90 | 15 |
0.75 | 24/0.20 | 0.5 | 2.15*4.30 | 21 |
Notes:
Conductors of high conductivity copper wires,Two conductors laid side by side,Both insulated with PVC compound formation,one core with a ridge for identification.
Class No 812
Twisted Twin
Size of conductor | Nominal thickness of insulation mm |
Nominal overall diameter of each core mm |
Approx. net weight per km
kg |
|
Nominal cross-sectional area mm2 |
Number and diameter of wires mm |
|||
0. 5 | 16/0.20 | 0.5 | 1.95 | 16 |
0.75 | 24/0.20 | 0.5 | 2.15 | 22 |
Notes:
Conductors of high conductivity copper wires, insulated with PVC compound, two cores twisted together.
- Next: Bvr Type Copper Conductor PVC Insulated Wires Building Wire
- Previous: H07V-U Type PVC Insulated PVC Sheathed Electrical Cable
Contact us