Overhead Power Transmission Lines Conductors ABC Triplex Bundled Cables
Product Description
Construction:
Concentric stranded or compressed 1350-H19 aluminum conductors, crosslinked polyethylene insulation. Insulated conductors surface printed, neutral triple yellow striped. Two phase and one neutral conductor twisted together (LH lay) or parallel if so specified. Black neutrals may be specified if desired.
Standards:
ASTM B-230, B-231 and ICEA S-66-524 UL Standard 854 for Type USE Federal Specification JC-30B NEC
Code name | Phase conductor | Neutral | Single phase conductor (in) | Outside diameter (in) | Weight per 1000ft (lbs) |
Ampacity | |||||
Size AWG |
Strand | Insulation thickness (mls) |
Size AWG |
Strand | Insulation thickness(mls) | Direct burial | In duct | ||||
Erksine | 6 | 7/w | 60 | 6 | 7/w | 60 | .299 | .646 | 143 | 95 | 70 |
Vassar | 4 | 7/w | 60 | 4 | 7/w | 60 | .345 | .754 | 203 | 125 | 90 |
Stephens | 2 | 7/w | 60 | 4 | 7/w | 60 | .403 | .842 | 264 | 165 | 120 |
Ramapo | 2 | 7/w | 60 | 2 | 7/w | 60 | .403 | .874 | 294 | 165 | 120 |
Brenau | 1/0 | 19/w | 80 | 2 | 7/w | 60 | .522 | 1.064 | 408 | 215 | 160 |
Bergen | 1/0 | 19/w | 80 | 1/0 | 19/w | 80 | .522 | 1.133 | 465 | 215 | 160 |
Converse | 2/0 | 19/w | 80 | 1 | 19/w | 80 | .566 | 1.174 | 502 | 245 | 180 |
Hunter | 2/0 | 19/w | 80 | 2/0 | 19/w | 80 | .566 | 1.228 | 560 | 245 | 180 |
Hollins | 3/0 | 19/w | 80 | 1/0 | 19/w | 80 | .616 | 1.276 | 606 | 280 | 205 |
Rockland | 3/0 | 19/w | 80 | 3/0 | 19/w | 80 | .616 | 1.336 | 678 | 280 | 205 |
Sweetbriar | 4/0 | 19/w | 80 | 2/0 | 19/w | 80 | .672 | 1.389 | 739 | 315 | 240 |
Monmouth | 4/0 | 19/w | 80 | 4/0 | 19/w | 80 | .672 | 1.457 | 828 | 315 | 240 |
Pratt | 250 | 37/w | 95 | 3/0 | 19/w | 80 | .748 | 1.538 | 893 | 345 | 265 |
Wesleyan | 350 | 37/w | 95 | 4/0 | 19/w | 80 | .851 | 1.736 | 1166 | 415 | 320 |
Holyoke | 500 | 37/w | 95 | 300 | 37/w | 95 | .979 | 2.008 | 1607 | 495 | 395 |
Rider | 500 | 37/w | 95 | 350 | 37/w | 95 | .979 | 2.035 | 1663 | 495 | 395 |
Fairfield | 750 | 61/w | 110 | 500 | 37/w | 95 | 1.188 | 2.086 | 2304 | 615 | 525 |
Ampacity: 90ºC conductor temperature, 20ºC ambient, RHO 50, 100% load factor for three conductor triplex with neutral carrying only unbalanced load. Technical data for cable with solid black neutral is identical to yellow extruded stripe data. All yellow extruded stripe cable is XLP insulation
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition. Packaging: Available 500 ft reels, 1,000 ft reels and longer lengths.
The above data are approximate and subject to normal manufacturing tolerances.
0.6/1KV Self support conductor abc cable, aerial bundle cable,
We can supply this conductor according to different recognized standards, such as IEC Standard, ANSI/ICEA , NFC, NBR, ITP ,customer special specification also can be satisfied.
Aerial Bundle Conductor-ABC(South Africa Standard Sizes)-SANS 1418-1
Table 01
Type of conductor or core | Norminal cross-sectional area mm2 | Nubmer of wires Min. |
Diameter of conductormm | Resistanceat 20ºC Ω/km Max. | Breaking force(N) | Thickness of insulation (mm) | Outer diameter of core(mm) | |||
Min. | Max. | Min. | Average | Min. | Min. | Max. | ||||
Phase or auxiliary or non-strain-bearing netural(aluminium) | +16 | 6 | 4.6 | 5.1 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 7.8 |
25 | 6 | 5.8 | 6.3 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.4 | |
35 | 6 | 6.8 | 7.3 | 0.868 | 4500 | 1.6 | 1.34 | 10.0 | 10.9 | |
50 | 6 | 7.9 | 8.4 | 0.641 | 6200 | 1.6 | 1.34 | 11.1 | 12.0 | |
70 | 12 | 9.7 | 10.2 | 0.443 | 8900 | 1.8 | 1.52 | 13.3 | 14.2 | |
95 | 15 | 11.0 | 12.0 | 0.320 | 12300 | 1.8 | 1.52 | 14.6 | 16.0 | |
120 | 15 | 12.5 | 13.5 | 0.253 | 15600 | 1.8 | 1.52 | 16.3 | 17.5 | |
150 | 15 | 13.9 | 15.0 | 0.206 | 19200 | 1.8 | 1.52 | 17.1 | 18.6 | |
Service connection(aluminium) | 16 | 6 | 4.6 | 5.2 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 8.0 |
25 | 6 | 5.6 | 6.5 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.6 | |
Service connection(copper) | 10 | 6 | – | 4.2 | 1.83 | 3600 | 1.2 | 0.98 | 6.2 | 7.0 |
16 | 6 | – | 5.3 | 1.15 | 5760 | 1.2 | 0.98 | 7.2 | 8.0 | |
25 | 6 | – | 6.6 | 0.727 | 8750 | 1.4 | 1.16 | 8.6 | 9.6 | |
Number and nominal diameter of wires mm |
||||||||||
Supporting core(aluminium alloy) |
54.6 | 7×3.15 | 9.2 | 9.6 | 0.630 | 16600 | 1.6 | 1.34 | 12.3 | 13.0 |
70 | 7×3.50 | 10.0 | 10.4 | 0.500 | 20100 | 1.6 | 1.34 | 12.9 | 13.6 | |
+Auxiliary conductors or cores only |
When a supporting core is specified in a tender invitation,the combinations listed in Table 02 below:
Table 02
1 | 2 |
Nominal cross sectional area of supporting conductor mm2 | Nominal cross-sectional areas of phase conductors mm2 |
54.6 | 25,35,50,70,95 |
70 | 70,95,120 |
95 | 95,120,150 |
Aerial Bundle Conductor-ABC(South Africa Custimized Size Specification)
Table 03
Type of conductor or core | Norminal cross-sectional area mm2 | Nubmer of wires | Diameter of conductormm | Resistanceat 20ºC Ω/km Max. | Breaking force(N) | Thickness of insulation (mm) | Outer diameter of core(mm) | |||
Min. | Max. | Min. | Average | Min. | Min. | Max. | ||||
Phase or auxiliary or non-strain-bearing netural(aluminium) | 16 | 7/1.65 | 4.6 | 5.1 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 7.8 |
25 | 7/2.15 | 5.8 | 6.3 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.4 | |
35 | 7/2.55 | 6.8 | 7.3 | 0.868 | 4500 | 1.6 | 1.34 | 10.0 | 10.9 | |
50 | 7/2.99 | 7.9 | 8.4 | 0.641 | 6200 | 1.6 | 1.34 | 11.1 | 12.0 | |
70 | 14/2.59 | 9.7 | 10.2 | 0.443 | 8900 | 1.8 | 1.52 | 13.3 | 14.2 | |
95 | 19/2.59 | 11.0 | 12.0 | 0.320 | 12300 | 1.8 | 1.52 | 14.6 | 16.0 | |
120 | 19/2.99 | 12.5 | 13.5 | 0.253 | 15600 | 1.8 | 1.52 | 16.3 | 17.5 | |
150 | 30/2.59 | 13.9 | 15.0 | 0.206 | 19200 | 1.8 | 1.52 | 17.1 | 18.6 | |
Service connection(aluminium) | 16 | 7/1.65 | 4.6 | 5.2 | 1.91 | 2070 | 1.2 | 0.98 | 7.0 | 8.0 |
25 | 7/2.15 | 5.6 | 6.5 | 1.2 | 3300 | 1.4 | 1.16 | 8.6 | 9.6 | |
Service connection(copper) | 10 | 7/1.35 | – | 4.2 | 1.83 | 3600 | 1.2 | 0.98 | 6.2 | 7.0 |
16 | 7/1.69 | – | 5.3 | 1.15 | 5760 | 1.2 | 0.98 | 7.2 | 8.0 | |
25 | 7/2.19 | – | 6.6 | 0.727 | 8750 | 1.4 | 1.16 | 8.6 | 9.6 | |
Supporting core(aluminium alloy) | 16 | 7/1.71 | 5.1 | 5.2 | 2.053 | 5070 | 1.4 | 1.16 | 7.9 | 8.0 |
25 | 7/2.15 | 6.4 | 6.5 | 1.314 | 8000 | 1.4 | 1.16 | 9.2 | 9.3 | |
35 | 7/2.48 | 6.6 | 7.5 | 0.986 | 10300 | 1.6 | 1.34 | 10.7 | 10.8 | |
50 | 7/2.89 | 7.7 | 8.4 | 0.720 | 14200 | 1.6 | 1.34 | 11.9 | 12.0 | |
54.6 | 7/3.15 | 9.2 | 9.6 | 0.630 | 16600 | 1.6 | 1.34 | 12.3 | 13.0 | |
70 | 7/3.50 | 10.0 | 10.4 | 0.500 | 20100 | 1.6 | 1.34 | 12.9 | 13.6 |
Why Choose us?
For over 20 years, Zhengzhou Jinyuan Wire and Cable Co., Ltd., as a professional cable manufacturer has been producing customized cable for a wide range of applications based on high quality, excellent service and competitive market prices. This is an elite team with experienced personnel and strong technical support. Our achievements benefit by having access to the largest market for cheap labor and abundant resources in China and our determination to exceed our clients’ expectations.
PRODUCTS & STANDARDS
We can produce more than 2,000 types of cables and wires, such as
Bare Conductor: AAC, AAAC, ACSR, ACSR/AW, ACAR, ACSS, ACSS/AW, Aluminum Clad Steel Wire/Strand, Bare Copper Conductors, Copper Clad Steel Wire/Strand, Copper Clad Aluminum(CCA), Galvanized Steel Wire/Strand, etc.
Overhead Insulated Cable: Covered Line Single Core Cable and Aerial Bundled Cable (ABC). ABC includes Duplex, Triplex, Quadruplex and more Cores Service Drop Cable.
PVC Insulated Wire up to 450/750V
PVC or XLPE Insulated Power Cable from 1kV to 36kV , armoured cable
Control Cable ,Welding Cable, Rubber Cable
We can produce cables according to the standards of IEC, ASTM, EN (BS, DIN, NF, etc.), AS/NZ and meet customers’ special requirements.
- Next: 600V Secondary Urd Cable Triplex Aluminum Conductor Overhead Insulated Cable
- Previous: Overhead Duplex Aluminum Service Drop & Ud ASTM Standard ABC Cable
Contact us
Similar Or Related
- No related articles