Mv-90, Power Cable, 5 Kv, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)
Product Description
Features
UL Listed as MV-90. Rated as Sunlight Resistance. Oil Resistance I jacket. True Triple extrusion system and
closed handling raw materials system, to eliminate any contact with ambient, until extrusion process ends.
Application
Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry
locations, installed in raceways, duct, and open air, aerially or directly buried as permitted by NEC.
Standards
UL 1072: Medium Voltage Power Cables.
ICEA S-93-639/NEMA WC74: 5 kV – 46 kV Shielded Power Cables.
ICEA S-97-682: Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.
AEIC CS8: Specification for Extruded Dielectric, Shielded Power Cables Rated 5 kV – 46 kV.
Specifications
Maximum operating voltage: 5 kV to 35 kV 100% and 133% IL
Maximum conductor operation temperatures: Wet and dry locations: Normal: 90 °C, Emergency: 130 °C, Short Circuit: 250 °C
Engineering Information
1. Conductor: Soft annealed uncoated copper compacted Class B per ASTM B496 or hard drawn Aluminum-1350 compacted Class B per ASTM B400. On request, strand filled or compressed strand. Sizes: 8 AWG (6 AWG Aluminum) up to 1000 kcmil.
2. Conductor Shield: Semi conducting cross-linked polyethylene (XLPE).
3. Insulation: Thermoset crosslinked polyethylene (XLPE). On request, TR-XLPE.
4. Insulation Shield: Semi conducting cross-linked polyethylene (XLPE).
5. Metallic Shield: Solid soft annealed uncoated copper wires per ASTM B3, helically applied and uniformly spaced.
6. Binder Tape: A suitable tape, as required.
7. Jacket: Black sunlight resistance and flame retardant polyvinyl chloride (PVC) compound.
100% and 133% Insulation Levels (90 mil) | |||||||
Size | Number of Strands | Conductor Nominal | Diameter Over Insulation | Jacket Thickness | Approximate Outside Diameter | Approximate Net Weight | |
Copper | Aluminum | ||||||
AWG of kcmil | in | in | mil | in | lb/kft | ||
6 | 7 | 0.17 | 0.38 | 60 | 0.63 | 229 | 172 |
4 | 7 | 0.21 | 0.43 | 60 | 0.68 | 291 | 202 |
2 | 7 | 0.27 | 0.48 | 60 | 0.73 | 392 | 250 |
1 | 19 | 0.30 | 0.51 | 60 | 0.76 | 455 | 275 |
1/0 | 19 | 0.34 | 0.55 | 60 | 0.80 | 535 | 308 |
2/0 | 19 | 0.38 | 0.59 | 80 | 0.88 | 668 | 382 |
3/0 | 19 | 0.42 | 0.64 | 80 | 0.93 | 793 | 433 |
4/0 | 19 | 0.48 | 0.69 | 80 | 0.98 | 949 | 494 |
250 | 37 | 0.52 | 0.75 | 80 | 1.03 | 1096 | 559 |
350 | 37 | 0.62 | 0.84 | 80 | 1.13 | 1443 | 689 |
500 | 37 | 0.74 | 0.96 | 80 | 1.25 | 1952 | 877 |
750 | 61 | 0.91 | 1.14 | 80 | 1.45 | 2828 | 1215 |
1000 | 61 | 1.06 | 1.30 | 80 | 1.61 | 3660 | 1510 |
- Next: Arc-Welding Cable, Welding Machine Cable, Flexible Cu/Epr, 600 V (ICEA S-75-381/NEMA WC 58/CAN/CSA C22.2 No. 96/UL 1581)
- Previous: Mv-90, Power Cable, 8 Kv, 1/C, Cu/XLPE/Cws/PVC (ICEA S-93-639/NEMA WC74/UL 1072)
Contact us
Similar Or Related
-
10X1.5mm2 Flame Retardant Copper Tape Screen Steel Tape Armored PVC Sheathed Control Cable 0.6/1kV
-
0.3/0.5kV 4X4mm2 Copper Wire Braiding PVC Insulation Low Voltage Control Power Cable
-
24X2.5mm2 XLPE Insulated Steel Tape Armoured Control/Instrumentation Cable IEC 60502-1
-
Low Voltage Single Core Power Cable 1X300 mm2 N2XCH CU/XLPE/CWS/LSF 0.6/1kV
-