Liydy-Cy Tp, Data Cable, 300/500 V, Flexible Cu/PVC/Tcwb/PVC/Petp/Tcwb/PVC Pair-Wise (DIN VDE 0812)
Product Description
Construction:
Conductor: Bare copper strands with reference to DIN VDE 0812
Insulation: PVC, YI2 acc. To DIN VDE 0207 part 4
Colour code: With reference to DIN 47100
Stranding: 2 cores twisted to pairs
Screen: Wrapped pair-wise with tinned copper wires
Inner sheath: Pair-wise PVC, YM1 acc. To DIN VDE 0207 part 5
Stranding: Pairs in concentric layers
Wrapping: PETP foil
Screen: Tinned Copper Braiding
Sheath material: PVC, YM1 acc. To DIN VDE 0207 part 5
Sheath colour: Grey (RAL 7032)
Outstanding features:
Good EMC characteristic
Flexible
Technical data:
Peak operating voltage: < 0, 25 mm2 = max. 350 V
≥ 0, 25 mm2 = max. 500 V
Testing voltage: < 0, 25 mm2 = 800 V
≥ 0, 25 mm2 = 1200 V
Min. Bending radius
Fixed laying: 5 x d
Flexible application: 10 x d
Radiation resistance: 8 x 107 cJ/kg
Temperature range
Fixed laying: -30/+70 ° C
Flexible application: -5/+70 ° C
Fire performance: Flame retardant and self-extinguishing acc. To IEC 60332-1-2 + EN 60332-1-2
Absence of acc. To RoHS directive of the European Union
no. of pairs x cross section | Outer Diameter | copper figure | cable weight |
n x 2 x mm2 | mm | kg/km | kg/km |
2 x 2 x 0,14 | 8,1 | 35,6 | 82 |
3 x 2 x 0,14 | 9,2 | 45,4 | 111 |
4 x 2 x 0,14 | 9,9 | 55,4 | 127 |
6 x 2 x 0,14 | 11,8 | 95,0 | 187 |
8 x 2 x 0,14 | 13,8 | 115,6 | 245 |
10 x 2 x 0,14 | 14,8 | 153,9 | 297 |
12 x 2 x 0,14 | 15,6 | 179,5 | 331 |
14 x 2 x 0,14 | 15,7 | 189,7 | 352 |
16 x 2 x 0,14 | 17,3 | 221,7 | 415 |
24 x 2 x 0,14 | 20,4 | 297,4 | 571 |
2 x 2 x 0,25 | 8,4 | 41,2 | 92 |
3 x 2 x 0,25 | 9,4 | 53,2 | 122 |
4 x 2 x 0,25 | 11,6 | 89,2 | 176 |
6 x 2 x 0,25 | 13,9 | 114,5 | 241 |
8 x 2 x 0,25 | 15,1 | 157,2 | 313 |
10 x 2 x 0,25 | 16,5 | 187,7 | 354 |
12 x 2 x 0,25 | 16,9 | 208,1 | 389 |
14 x 2 x 0,25 | 17,4 | 238,2 | 426 |
16 x 2 x 0,25 | 18,7 | 259,7 | 480 |
24 x 2 x 0,25 | 23,7 | 365,9 | 709 |
2 x 2 x 0,34 | 10,6 | 57,4 | 133 |
3 x 2 x 0,34 | 11,2 | 70,9 | 152 |
4 x 2 x 0,34 | 12,2 | 99,9 | 198 |
6 x 2 x 0,34 | 14,6 | 142,0 | 280 |
8 x 2 x 0,34 | 17,1 | 201,3 | 382 |
10 x 2 x 0,34 | 18,4 | 223,9 | 429 |
12 x 2 x 0,34 | 18,8 | 249,2 | 474 |
14 x 2 x 0,34 | 20,6 | 316,6 | 574 |
16 x 2 x 0,34 | 20,9 | 343,2 | 626 |
24 x 2 x 0,34 | 24,8 | 446,5 | 851 |
2 x 2 x 0,50 | 10,8 | 61,8 | 142 |
3 x 2 x 0,50 | 11,2 | 77,8 | 167 |
4 x 2 x 0,50 | 13,4 | 115,6 | 233 |
6 x 2 x 0,50 | 15,0 | 174,3 | 322 |
8 x 2 x 0,50 | 18,2 | 227,8 | 433 |
10 x 2 x 0,50 | 19,9 | 270,8 | 505 |
12 x 2 x 0,50 | 20,8 | 303,7 | 555 |
14 x 2 x 0,50 | 21,4 | 336,2 | 607 |
16 x 2 x 0,50 | 23,1 | 393,7 | 696 |
24 x 2 x 0,50 | 26,5 | 533,9 | 960 |
- Next: AAAC/Aasc Conductor, All Aluminum Alloy Conductor (CAN/CSA CS 49.1)
- Previous: Primary Ud Cable, 25 Kv, Cu/Tr-XLPE/Neutral/PVC (AEIC CS 8/ICEA S-94-649)
Contact us
Similar Or Related
-
PVC/XLPE Insulation Copper Conductor Armoured Cable 4 Core 25mm
-
High Quality 0.6/1kv 95mm2 Aluminum Conductor PVC Power Cable
-
Liycy (B) Tp Data Cable, 300/500 V, Flexible Cu/PVC/Petp/Tcwb/PVC (DIN VDE 0812)
-
Liyy, Data Cable, 300/500 V, Flexible Cu/PVC/PVC (DIN VDE 0812)
-
Liyy Tp, Data Cable, 300/500 V, Flexible Cu/PVC/Petp/PVC Twisted Pairs (DIN VDE 0812)
-
Liydy-Cy Tp, Data Cable, 300/500 V, Flexible Cu/PVC/Tcwb/PVC/Petp/Tcwb/PVC Pair-Wise (DIN VDE 0812)