Light Rubber Sheathed and Insulated Flexible Cable H05rr-F

Light Rubber Sheathed and Insulated Flexible Cable H05rr-F

Light Rubber Sheathed and Insulated Flexible Cable H05rr-F

H05RR-F

Hebei Huatong Cables

ISO9001, CE, UL, CCC, RoHS, VDE

Lighting, Household Appliance

Round Wire

Rubber

Epr

Copper

Household Use

Stranded

Insulated

Hebei Huatong

Roll

50m/roll, 100m/roll, 500m/drum

China

8544492100

Product Description

Application

 

Light rubber cable, used for easy-duty and medium mechanical loads in dry areas. Suitable for household, kitchens, offices and workshops (for inst. tailoring) for smaller electrical devices (washing-machines, vacuum-cleaners, irons, household appliances, soldering sets etc.) and mobile devices operating in heavier conditions, such as light industrial and agricultural machines. Not suitable for permanent outdoor use. Ozone-resistant, allowed contact with oils and greases.

 

Construction

 

Conductor:         bare or tinned copper conductor, fine wired stranded, class 5 acc. to IEC 60228 / HD 383 /                                    DIN VDE 0295

 Insulation:          rubber compound on ethylene-propylene basis (EPM, earlier: EPR), i.e. EI4 acc. to DIN VDE                                0282 part 1       

 

Sheath:              rubber compound on ethylene-propylene basis (EPM, earlier: EPR) or on natural and poly- butadiene-styrene rubber basis  (NR + PBS, earlier: SBR), i.e. EM3 acc. to DIN VDE 0282 part 1, extruded sheath able to fill up the interstices between the conductors

sheath :                black

core color:           acc. to HRN HD 308 S2 / VDE 0293-308 

 

 

Standard:             HRN HD 22.4 S3        IEC 60245-4        DIN VDE 0282 part 4

Technical data:
Temperature range:
                         during installation:            -30 °C up to +60 °C
                              maximal operating temp.:              +60 °C
                               at short circuit of max. 5 s:   up to 200 °C
Maximal operating voltage:
alternating current three-phase and single-phase:    Uο/U = 318/550 V
direct current:                                                              Uο/U = 413/825 V
 Nominal voltage:                  Uο/U = 300/500 V
 Test voltage :                         2000 V
  Minimal inner bending radius: 7.5D

Behaviour in fire:                     IEC 60332-1
 Ozone resistance:    acc. to DIN VDE 0472 part 805     
         

 

Dimensions – number of cores x conductor cross-section* Construction of individual conductor Conductor diameter Insulation thickness Sheath thickness External diameter Conductor resistance at 20 °C Cu weight Cable weight Packing **
  nominal nominal nominal nominal min-max. max.   approx.  
mm² n x mm mm mm mm mm Ω/km kg/km kg/km  
2 x 0,75 24 x 0,20 1,1 0,6 0,8 5,7 – 18,2 26,7 14,4 63 c.100
2 x 1 32 x 0,20 1,3 0,6 0,9 6,1 – 18,8 20,0 19,2 73 c.100
2 x 1,5 30 x 0,25 1,6 0,8 1,0 7,6 – 10,5 13,7 28,8 103 c.100
2 x 2,5 50 x 0,25 2,0 0,9 1,1 9,0 – 12,5 8,21 48 146 c.100
 
3 G 0,75 24 x 0,20 1,1 0,6 0,9 6,2 – 18,8 26,7 21,6 78 c.100
3 G 1 32 x 0,20 1,3 0,6 0,9 6,5 – 19,2 20,0 28,8 88 c.100
3 G 1,5 30 x 0,25 1,6 0,8 1,0 8,0 – 11,0 13,7 43,2 125 c.100
3 G 2,5 50 x 0,25 2,0 0,9 1,1 9,6 – 13,0 8,21 72,0 177 c.100
 
4 G 0,75 24 x 0,20 1,1 0,6 0,9 6,8 – 09,6 26,7 28,8 94 c.100
4 G 1 32 x 0,20 1,3 0,6 0,9 7,1 – 10,0 20,0 38,4 106 c.100
4 G 1,5 30 x 0,25 1,6 0,8 1,1 9,0 – 12,5 13,7 57,6 154 c.100
4 G 2,5 50 x 0,25 2,0 0,9 1,2 10,7 – 14,0 8,21 96,0 222 c.100
 
5 G 1,5 30 x 0,25 1,6 0,8 1,1 9,8 – 13,5 13,7 72 182 c.100
5 G 2,5 50 x 0,25 2,0 0,9 1,2 11,9 – 15,5 8,21 120 269 c.100

*) G = With protective yellow/green conductor x = Without protective yellow/green conductor

**) Packing: R100 = ring 100 m

 

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.