Product Description
Application: Used in remote control system in power plant and substation. It is lighter and more flexible than conventional rubber insulated lead sheathed control cable, also excellent in fire proof and anti-abrasion quality.
Construction- Conductors:Annealed Copper Wire
– Insulation : PVC
– Core Identification : Coloring Method – below 4 cores
(2 cores – Black, White /3 cores – Black, White, Red )
Numbering Method (Above 5 cores)
– Sheath : PVC
Class and SymbolsPVC Insulated PVC Sheathed Control Cable:CVV
PVC Insulated PVC Sheathed Control Cable (Solid Type):CVS
PVC Insulated PVC Sheathed Control Cable (Shield Type):CVV-S, CVV-SB
Flame-Retardant PVC Insulated PVC Sheathed Control Cable:FR-CVV
Flame-Retardant PVC Insulated PVC Sheathed Control Cable (Shield Type):TFR-CVVS
2 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
2 | 0.5 | 7/0.30 | 0.8 | 1.8 | 10.0 | 36.0 | 0.0162 | 98 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 10.0 | 24.5 | 0.0142 | 110 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 10.5 | 18.1 | 0.0135 | 115 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 11.0 | 12.1 | 0.0115 | 135 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 12.0 | 7.41 | 0.0093 | 180 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 14.5 | 4.61 | 0.0092 | 255 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 15.5 | 3.08 | 0.0078 | 320 | 500/D |
3 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
3 | 0.5 | 7/0.30 | 0.8 | 1.8 | 10.0 | 36.0 | 0.0162 | 110 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 10.5 | 24.5 | 0.0142 | 125 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 11.0 | 18.1 | 0.0135 | 135 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 11.5 | 12.1 | 0.0115 | 160 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 13.0 | 7.41 | 0.0093 | 220 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 15.0 | 4.61 | 0.0092 | 315 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 16.5 | 3.08 | 0.0078 | 405 | 500/D |
4 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
4 | 0.5 | 7/0.30 | 0.8 | 1.8 | 11.0 | 36.0 | 0.0162 | 130 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 11.5 | 24.5 | 0.0142 | 150 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 11.5 | 18.1 | 0.0135 | 160 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 12.5 | 12.1 | 0.0115 | 195 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 14.0 | 7.41 | 0.0093 | 265 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 16.5 | 4.61 | 0.0092 | 390 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 17.0 | 3.08 | 0.0078 | 510 | 500/D |
5 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
5 | 0.5 | 7/0.30 | 0.8 | 1.8 | 11.5 | 36.0 | 0.0162 | 150 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 12.5 | 24.5 | 0.0142 | 175 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 12.5 | 18.1 | 0.0135 | 190 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 13.5 | 12.1 | 0.0115 | 230 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 15.0 | 7.41 | 0.0093 | 320 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 18.0 | 4.61 | 0.0092 | 470 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 19.5 | 3.08 | 0.0078 | 620 | 500/D |
6 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
6 | 0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 36.0 | 0.0162 | 165 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 13.0 | 24.5 | 0.0142 | 190 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 18.1 | 0.0135 | 205 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 12.1 | 0.0115 | 255 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 16.0 | 7.41 | 0.0093 | 355 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 19.5 | 4.61 | 0.0092 | 525 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 21.0 | 3.08 | 0.0078 | 690 | 500/D |
7 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
7 | 0.5 | 7/0.30 | 0.8 | 1.8 | 12.5 | 36.0 | 0.0162 | 170 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 13.0 | 24.5 | 0.0142 | 200 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 13.5 | 18.1 | 0.0135 | 215 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 14.5 | 12.1 | 0.0115 | 270 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 16.0 | 7.41 | 0.0093 | 380 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 19.5 | 4.61 | 0.0092 | 570 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 21.0 | 3.08 | 0.0078 | 795 | 500/D |
8 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
8 | 0.5 | 7/0.30 | 0.8 | 1.8 | 13.5 | 36.0 | 0.0162 | 195 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 14.0 | 24.5 | 0.0142 | 230 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 14.5 | 18.1 | 0.0135 | 250 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 15.5 | 12.1 | 0.0115 | 310 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 17.5 | 7.41 | 0.0093 | 440 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 21.0 | 4.61 | 0.0092 | 660 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 23.0 | 3.08 | 0.0078 | 875 | 500/D |
9 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
9 | 0.5 | 7/0.30 | 0.8 | 1.8 | 14.0 | 36.0 | 0.0162 | 220 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 15.0 | 24.5 | 0.0142 | 265 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 15.5 | 18.1 | 0.0135 | 285 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 16.5 | 12.1 | 0.0115 | 355 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 18.5 | 7.41 | 0.0093 | 505 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 22.5 | 4.61 | 0.0092 | 760 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 24.5 | 3.08 | 0.0078 | 1015 | 500/D |
10 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
10 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 240 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 16.0 | 24.5 | 0.0142 | 285 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 16.5 | 18.1 | 0.0135 | 310 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 18.0 | 12.1 | 0.0115 | 385 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 20.0 | 7.41 | 0.0093 | 550 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 24.5 | 4.61 | 0.0092 | 825 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 27.0 | 3.08 | 0.0078 | 1100 | 500/D |
11 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
11 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 255 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 16.5 | 24.5 | 0.0142 | 315 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 17.0 | 18.1 | 0.0135 | 340 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 18.5 | 12.1 | 0.0115 | 425 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 21.0 | 7.41 | 0.0093 | 605 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 25.0 | 4.61 | 0.0092 | 915 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 27.5 | 3.08 | 0.0078 | 1220 | 500/D |
12 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
12 | 0.5 | 7/0.30 | 0.8 | 1.8 | 15.5 | 36.0 | 0.0162 | 265 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 16.5 | 24.5 | 0.0142 | 320 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 17.0 | 18.1 | 0.0135 | 345 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 18.5 | 12.1 | 0.0115 | 440 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 21.0 | 7.41 | 0.0093 | 630 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 25.0 | 4.61 | 0.0092 | 950 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 27.5 | 3.08 | 0.0078 | 1270 | 500/D |
13 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
13 | 0.5 | 7/0.30 | 0.8 | 1.8 | 16.5 | 36.0 | 0.0162 | 295 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 17.5 | 24.5 | 0.0142 | 355 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 18.0 | 18.1 | 0.0135 | 380 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 19.5 | 12.1 | 0.0115 | 485 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 22.0 | 7.41 | 0.0093 | 695 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 26.5 | 4.61 | 0.0092 | 1050 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 29.0 | 3.08 | 0.0078 | 1405 | 500/D |
14 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
14 | 0.5 | 7/0.30 | 0.8 | 1.8 | 16.5 | 36.0 | 0.0162 | 300 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 17.5 | 24.5 | 0.0142 | 360 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 18.0 | 18.1 | 0.0135 | 390 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 19.5 | 12.1 | 0.0115 | 495 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 22.0 | 7.41 | 0.0093 | 715 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 26.5 | 4.61 | 0.0092 | 1085 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 29.0 | 3.08 | 0.0078 | 1455 | 500/D |
15 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
15 | 0.5 | 7/0.30 | 0.8 | 1.8 | 17.0 | 36.0 | 0.0162 | 330 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 18.5 | 24.5 | 0.0142 | 395 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.0 | 18.1 | 0.0135 | 425 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 20.5 | 12.1 | 0.0115 | 545 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 23.0 | 7.41 | 0.0093 | 785 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 28.0 | 4.61 | 0.0092 | 1195 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 31.0 | 3.08 | 0.0078 | 1600 | 500/D |
16 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
16 | 0.5 | 7/0.30 | 0.8 | 1.8 | 17.0 | 36.0 | 0.0162 | 330 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 18.5 | 24.5 | 0.0142 | 400 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.0 | 18.1 | 0.0135 | 435 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 20.5 | 12.1 | 0.0115 | 555 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 23.0 | 7.41 | 0.0093 | 805 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 28.0 | 4.61 | 0.0092 | 1230 | 500/D | |
6 | 7/1.04 | 1.0 | 1.8 | 31.0 | 3.08 | 0.0078 | 1650 | 500/D |
17 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
17 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 355 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 430 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 465 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 595 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 865 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1315 | 500/D | |
6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1785 | 500/D |
18 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
18 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 360 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 435 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 475 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 605 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 885 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1350 | 500/D | |
6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1835 | 500/D |
19 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
19 | 0.5 | 7/0.30 | 0.8 | 1.8 | 18.0 | 36.0 | 0.0162 | 365 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 19.0 | 24.5 | 0.0142 | 445 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 19.5 | 18.1 | 0.0135 | 480 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 21.5 | 12.1 | 0.0115 | 620 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 24.0 | 7.41 | 0.0093 | 905 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 29.5 | 4.61 | 0.0092 | 1385 | 500/D | |
6 | 7/1.04 | 1.0 | 1.9 | 32.5 | 3.08 | 0.0078 | 1885 | 500/D |
20 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
20 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.0 | 36.0 | 0.0162 | 390 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 20.0 | 24.5 | 0.0142 | 475 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 20.5 | 18.1 | 0.0135 | 515 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 22.5 | 12.1 | 0.0115 | 665 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 25.5 | 7.41 | 0.0093 | 975 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 31.0 | 4.61 | 0.0092 | 1490 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 34.5 | 3.08 | 0.0078 | 2040 | 500/D |
21 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
21 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.0 | 36.0 | 0.0162 | 400 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 20.0 | 24.5 | 0.0142 | 490 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 20.5 | 18.1 | 0.0135 | 530 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 22.5 | 12.1 | 0.0115 | 685 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 25.5 | 7.41 | 0.0093 | 1005 | 500/D | |
4 | 7/0.85 | 1.0 | 1.8 | 31.0 | 4.61 | 0.0092 | 1540 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 34.5 | 3.08 | 0.0078 | 2040 | 500/D |
22 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
22 | 0.5 | 7/0.30 | 0.8 | 1.8 | 20.0 | 36.0 | 0.0162 | 430 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 21.0 | 24.5 | 0.0142 | 520 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 21.5 | 18.1 | 0.0135 | 565 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 23.5 | 12.1 | 0.0115 | 730 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 265 | 7.41 | 0.0093 | 1070 | 500/D | |
4 | 7/0.85 | 1.0 | 1.9 | 32.5 | 4.61 | 0.0092 | 1655 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2245 | 500/D |
23 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
23 | 0.5 | 7/0.30 | 0.8 | 1.8 | 19.5 | 36.0 | 0.0162 | 440 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 21.0 | 24.5 | 0.0142 | 540 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 21.5 | 18.1 | 0.0135 | 585 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 23.5 | 12.1 | 0.0115 | 755 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 26.5 | 7.41 | 0.0093 | 1105 | 500/D | |
4 | 7/0.85 | 1.0 | 1.9 | 32.5 | 4.61 | 0.0092 | 1710 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2330 | 500/D |
24 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
24 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 460 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 22.0 | 24.5 | 0.0142 | 560 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 605 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 24.5 | 12.1 | 0.0115 | 785 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 28.0 | 7.41 | 0.0093 | 1150 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 34.5 | 4.61 | 0.0092 | 1795 | 500/D | |
6 | 7/1.04 | 1.0 | 2.0 | 36.5 | 3.08 | 0.0078 | 2330 | 500/D |
25 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
25 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 490 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 595 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 645 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 835 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1225 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1915 | 500/D | |
6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2595 | 500/D |
26 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
27 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 500 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 610 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 665 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 860 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1270 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1985 | 500/D | |
6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2700 | 500/D |
27 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
27 | 0.5 | 7/0.30 | 0.8 | 1.8 | 21.0 | 36.0 | 0.0162 | 500 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 22.5 | 24.5 | 0.0142 | 610 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 23.0 | 18.1 | 0.0135 | 665 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 25.5 | 12.1 | 0.0115 | 860 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 28.5 | 7.41 | 0.0093 | 1270 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 35.5 | 4.61 | 0.0092 | 1985 | 500/D | |
6 | 7/1.04 | 1.0 | 2.1 | 39.5 | 3.08 | 0.0078 | 2700 | 500/D |
28 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
28 | 0.5 | 7/0.30 | 0.8 | 1.8 | 22.0 | 36.0 | 0.0162 | 535 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 23.5 | 24.5 | 0.0142 | 650 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 24.0 | 18.1 | 0.0135 | 710 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 26.0 | 12.1 | 0.0115 | 915 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 30.0 | 7.41 | 0.0093 | 1350 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 37.0 | 4.61 | 0.0092 | 2110 | 500/D | |
6 | 7/1.04 | 1.0 | 2.2 | 41.5 | 3.08 | 0.0078 | 2885 | 500/D |
29 Core CVV Control Cable
No. of core | Nominal cross- sectional area sq.mm |
No.& dia. of wires No./mm |
Thickness of insulation mm |
Thickness of sheath mm |
Overall diameter (Approx.) mm |
Maximum conductor resistance (at20C) Ohm/km |
Minimum insulation resistance (at70C) Ohm/km |
Cable weight (Approx.) kg/km |
Standard Length m |
29 | 0.5 | 7/0.30 | 0.8 | 1.8 | 22.0 | 36.0 | 0.0162 | 540 | 500/D |
0.75 | 7/0.37 | 0.8 | 1.8 | 23.5 | 24.5 | 0.0142 | 660 | 500/D | |
1 | 7/0.40 | 0.8 | 1.8 | 24.0 | 18.1 | 0.0135 | 715 | 500/D | |
1.5 | 7/0.50 | 0.8 | 1.8 | 26.0 | 12.1 | 0.0115 | 930 | 500/D | |
2.5 | 7/0.67 | 0.8 | 1.8 | 30.0 | 7.41 | 0.0093 | 1370 | 500/D | |
4 | 7/0.85 | 1.0 | 2.0 | 37.0 | 4.61 | 0.0092 | 2145 | 500/D | |
6 | 7/1.04 | 1.0 | 2.2 | 41.5 | 3.08 | 0.0078 | 2940 | 500 |
- Next: Factory Low Price Unarmoured PVC Insulated 4X150 Sq. mm Aluminium Power Cable
- Previous: Xv-R Cable Single Core Cable Pex Insulation Cable
Contact us
Similar Or Related
- No related articles
-