Copper PVC Insulated PVC Jacketed Electric Building Wire

Copper PVC Insulated PVC Jacketed Electric Building Wire

Copper PVC Insulated PVC Jacketed Electric Building Wire

BV/BLV/BVR

Insulated

Solid or Stranded

Heating

Copper

PVC

PVC

Round Wire

LSOH

ISO9001, CE

Jytop

Max. DC Resistance @ 20 Degree 36.0 Ohm/Km

Max. DC Resistance @ 20 Degree 24.5 Ohm/Km

Max. DC Resistance @ 20 Degree 18.0 Ohm/Km

ASTM, AS/NZS, BS, CSA, DIN, IEC…

Ce, ISO 9001

JYTOP

100m/Coil

1.5~185mm2

Zhengzhou, China

8544492100

Product Description

Copper PVC Insulated PVC Jacketed Electric Building Wire

When used as Type THHN, conductor is suitable for use in dry locations at temperatures not to exceed 90° C;
When used as Type THWN-2*, conductor is suitable for use in wet or dry locations at temperatures not to exceed 90° C or not to exceed 75° C when exposed to oil or coolant;
When used as Type MTW, conductor is suitable for use in wet locations or when exposed to oil or coolant at temperatures not to exceed 60° C or dry locations at temperatures not to exceed 90° C (with ampacity limited to that for 75° C conductor temperature per NFPA 79)

Conductor temperatures not to exceed 105° C in dry locations when rated AWM and used as appliance wiring material. Voltage for all applications is 600 volts

STANDARDS & REFERENCE :
THHN or THWN-2* or MTW (also AWM) meets or exceeds all applicable ASTM specifications, UL Standard 83, UL Standard 1063 (MTW), Federal Specification A-A-59544, and requirements of the National Electrical Code.

APPLICATION Suitable for use as follows:
THHN or THWN-2* conductors are primarily used in conduit and cable trays for services, feeders, and branch circuits in commercial or industrial applications as specified in the National Electrical Code 2;

Range of our products :
1. 227IEC01/05 standard .BV/BLV type, copper conductor PVC insulated wires / aluminum conductor PVC insulated wires , fized laid indoors , conduits etc, long term working temperature 70 selsius degree.
2. 227IEC07 Standard, BV-90 type, heat resistant copper conductor PVC insulated wires at 90 selsius degree,mainly be laid at the places of high temperature environment and cab be laid indoors ,conduits.
BVR type , copper conductor PVC insulated flexible wire , be for laying pemanent place where flexible required, long term working temperature 70 selsius degree.
3. 227IEC10 standard, BW type, copper conductor PVC insulated PVC sheathed round wires,
BLW type, aluminum conductor PVC insulated PVC sheathed round wires,
BWB type, Copper conductor PVC insulated PVC sheathed flat wires.
BLWB type, aluminum conductor PVC insulated sheathed flat wires,
The above , mainly be fixed lain, fit for the places with high mechanical protection and moisture place, can be laid in the aire or underground, long term working temperature 70 selsius degree.
4. 227 IEC02RV / 227IEC06RV standard, copper conductor PVC insulated flexible connector,
227IEC42 RVB , copper conductor PVC insulated flat flexible connector .
RVS , copper conductor PVC insulated flexible twisting connector wire.
227IEC 52 RW, 227 IEC 53 RW ,standard, copper conductor PVC insulated PVC sheathed round flexible connector (light and common type ) , mainly used at middle and light style moving electronics, home applicances, power and lighting and the places where flexible required, long term working temperature 70 selsius degree.

227 IEC 05 BV wire :

Nominal sectional area ,mm² Number and diameter
of conductor
no. /mm
Nominal thickness of insulation, mm Max overall diameter
mm
conductor resistance at 20ºCΩ/km Min insulated resistance at 70ºC MΩ/km weight KG/KM
0.5 1/0.80 0.6 2.4 36.0 0.015 8.1
0.75 1/0.97 0.6 2.6 24.5 0.012 10.6
1 1/1.13 0.6 2.8 18.1 0.011 13.2

227 IEC 01 BV/BLV type PVC insulated wire :

Nominal sectional area mm² Number and diameter
of conductor
no. /mm
Nominal thickness of insulation, mm Max overall diameter
mm
conductor resistance at 20ºCΩ/km Min insulated resistance at 70ºC MΩ/km weight KG/KM
Cu Al Cu Al
1.5 1/1.38 0.7 3.3 12.1 0.011 19.2
1.5 7/0.52 0.7 3.5 12.1 0.010 20.6
2.5 1/1.78 0.8 3.9 7.41 11.8 0.010 30.8 15.0
4 1/2.25 0.8 4.4 4.61 7.39 0.0085 45.5 21.0
6 1/2.76 0.8 4.9 3.08 4.91 0.0070 65.0 29.0
10 7/1.35 1.0 7.0 1.83 3.08 0.0065. 110.0 52.0
16 7/1.70 1.0 8.0 1.15 1.91 0.0050 170.0 70.0
25 7/2.14 1.2 10.0 0.727 1.20 0.0050 270.0 110.0
35 7/2.52 1.2 11.5 0.524 0.868 0.0040 364.0 150.0
50 19/1.78 1.4 13.0 0.387 0.641 0.0045 500.0 200.0
70 19/2014 1.4 15.0 0.268 0.443 0.0035 688.0 269.0
95 19/2.52 1.6 17.5 0.193 0.320 0.0035 953.0 360.0
120 37/2.03 1.6 19.0 0.153 0.253 0.0032 1168.0 449.0
150 37/2.25 1.8 21.0 0.124 0.206 0.0032 1466.0 551.0
185 37/2.52 2.0 32.5 0.099 0.164 0.0032 1808.0 668.0

Type BVR 450/750V copper conductor PVC insulated flexible wire:

Nominal sectional area mm² Number and diameter
of conductor
no. /mm
Nominal thickness of insulation, mm Max overall diameter
mm
conductor resistance at 20ºCΩ/km Min insulated resistance at 70ºC MΩ/km weight KG/KM
2.5 9/0.41 0.8 4.2 7.41 0.011 33.0
4 19/0.52 0.8 4.8 4.61 0.009 48.0
6 19/0.64 0.8 5.6 3.08 0.0084 68.0
10 49/0.52 1.0 7.6 1.83 0.0072 115.0
16 49/0.64 1.0 8.8 1.15 0.0062 176.0
25 98/0.58 1.2 11.0 0.727 0.0058 272.0
35 133/0.58 1.2 12.5 0.524 0.0052 384.0
50 133/0.68 1.4 16.5 0.387 0.0051 510.0
70 189/0.68 1.4 16.5 0.268 0.0045 714.0
95 259/0.68 1.6 19.5 0.139 0.0035 965.0
120 259/0.76 1.8 22.0 0.153 0.0032 1210.0
150 259/0.85 1.8 25.0 0.124 0.0032 1510.0