Copper Conductor PE Sheath Lsoh Cable Low Voltage
Product Description
IEC 60502-1: Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 30 kV (Um=36 kV) – Part 1: Cables for rated voltages of 1 kV (Um=1.2 kV) and 3 kV (Um=3.6 kV)
Application
This LSOH (low smoke and zero-halogen) Cable is used in power transmission lines of rated voltage 1KV and below such as high buildings, hospitals, museums, etc. It releases little smoke and halogen on fire and can reduce the dangers to people.
Product Details
1) Conductor: Solid or stranded copper
2) Sectional area: 2.5~400 mm2
3) Insulation: XLPE
4) No. of cores: 1, 2, 3, 4, 5, 3+1, 3+2, 4+1
5) Outer sheath: PVC
6) Max. working temperature: 90ºC
7) Cable size (4 cores)
Cores x Area (No. x mm2) |
Insulation Thick. (mm) |
Sheath Thick. (mm) |
Overall Dia. (mm) |
Approx. Weight (kg/km) |
Max. DC Resist. at 20ºC (Ω/km) |
4 x 2.5 | 0.7 | 1.8 | 12.4 | 204 | 7.41 |
4 x 4 | 0.7 | 1.8 | 13.5 | 273 | 4.61 |
4 x 6 | 0.7 | 1.8 | 14.8 | 362 | 3.08 |
4 x 10 | 0.7 | 1.8 | 16.7 | 535 | 1.83 |
4 x 16 | 0.7 | 1.8 | 19.0 | 780 | 1.15 |
4 x 25 | 0.9 | 1.8 | 21.9 | 1152 | 0.727 |
4 x 35 | 0.9 | 1.8 | 23.7 | 1524 | 0.524 |
4 x 50 | 1.0 | 1.9 | 25.9 | 2010 | 0.387 |
4 x 70 | 1.1 | 2.1 | 29.9 | 2858 | 0.268 |
4 x 95 | 1.1 | 2.2 | 33.7 | 3870 | 0.193 |
4 x 120 | 1.2 | 2.3 | 37.3 | 4866 | 0.153 |
4 x 150 | 1.4 | 2.5 | 41.4 | 6013 | 0.124 |
4 x 185 | 1.6 | 2.7 | 45.8 | 7533 | 0.0991 |
4 x 240 | 1.7 | 2.9 | 51.6 | 9783 | 0.0754 |
4 x 300 | 1.8 | 3.1 | 56.7 | 12137 | 0.0601 |
4 x 400 | 2.0 | 3.3 | 63.5 | 15527 | 0.0470 |
Packaging details
Polyethylene film packaging 1) Usually used for cables with an overall diameter 10mm and below 2) 100 meters per roll or as per customer’s requirements 3) Packaging dimension: 50cm * 50cm * 20cm or below 4) Weight: 30 kg/roll or below |
Steel-wood drum packaging 1) Used for cables with a overall diameter of 10mm and above 2) Drum size: 180cm * 180cm *110cm (different sizes are available according to packaging length) 3) Standard length: as per customer’s requirements. |
Customer service
1) Select the right cable as per customer’s requirements
2) Design suitable packaging to guarantee safe and the most economic delivery
3) Provide installation and use guidance
4) Product quality guarantee under the normal use
- Next: Copper Conductor PVC Sheath 6 Core Low Voltage Control Cable
- Previous: Underground Power Line Aluminum Conductor LV Cable
Contact us
Similar Or Related