Cable Price List 0.6kv/1kv Aerial Bunched Cable ABC Triplex Shrimp/Prawn

Cable Price List 0.6kv/1kv Aerial Bunched Cable ABC Triplex Shrimp/Prawn

Cable Price List 0.6kv/1kv Aerial Bunched Cable ABC Triplex Shrimp/Prawn

ABC Cable

Jinyuan

ABC

ISO, CCC, CE

Aluminum

Round Wire

None

XLPE/PE

AC Cable

Low and Medium Voltage Cable

Overhead

ABC Triplex Shrimp/Prawn

ABC Triplex

Manufacturer

400

100000m2

HUATONG

Drum/Container

ASTM BS EN

China

7614900000

Product Description

Cable Price list 0.6kv/1kv Aerial Bunched Cable ABC Triplex Shrimp/Prawn
APPLICATIONS
Used to supply power, usually from a pole-mounted transformer, to the user’s service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLP) insulated conductors.
 
SPECIFICATIONS
Jinyuan’s triplex service drop cable meets or exceeds the following ASTM specifications:
• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric-Lay-Stranded.
• B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR).
• B-399 Stranded 6201-T81 Aluminum Alloy Conductors.
• B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
Jinyuan’s triplex service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
CONSTRUCTION
Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or crosslinked polyethylene (XLP). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.

Triplex Service Drop                  
Code* Word Phase Conductor Bare Neutral Messenger Weight
per 1000 ft. (lbs.)
Allowable
Ampacities+
Size
(AWG)
Strand-
ing
Insul.
Thick.
(mils)
Equiv. Dia.
(AWG)++
Size++
(kcmil)
Strand-ing Rated
Strength
(lbs.)
XLP POLY XLP POLY
6201 ALLOY NEUTRAL-MESSENGER
Minex 6 1 45 6 30.58 7 1110 101 101 85 70
Hippa 6 7 45 6 30.58 7 1110 107 107 85 70
Prawn 4 1 45 4 48.69 7 1760 152 152 115 90
Bamacle 4 7 45 4 48.69 7 1760 160 160 115 90
Shrimp 2 7 45 2 77.47 7 2800 243 243 150 120
Gammarus 1/0 7 60 1/0 123.3 7 4460 390 390 205 160
Leda 1/0 9 60 1/0 123.3 7 4460 384 384 205 160
Dungenese 2/0 7 60 2/0 155.4 7 5390 483 483 235 185
Cyclops 2/0 11 60 2/0 155.4 7 5390 474 474 235 185
Flustra 3/0 17 60 3/0 195.7 7 6790 587 587 275 215
Lepas 4/0 18 60 4/0 246.9 7 8560 728 728 315 245
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun.
Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. 
Code* Word Phase Conductor Bare Neutral Messenger Weight
per 1000 ft. (lbs.)
Allowable
Ampacities+
Size
(AWG or kcmil)
Strand-
ing
Insul.
Thick.
(mils)
Size
(AWG or kcmil)
Strand-ing Rated
Strength
(lbs.)
XLP POLY XLP POLY
AAC NEUTRAL-MESSENGER
Patella 6 7 45 6 7 563 103 103 85 70
Oyster 4 7 45 4 7 881 154 154 115 90
Clam 2 7 45 2 7 1350 233 233 150 120
Murex 1/0 7 60 1/0 7 1990 374 374 205 160
Purpura 1/0 9 60 1/0 7 1990 368 368 205 160
Nassa 2/0 7 60 2/0 7 2510 462 462 235 185
Melita 3/0 17 60 3/0 19 3310 562 562 275 215
Portunus 4/0 18 60 4/0 19 4020 696 696 315 245
Nannynose 336.4 19 80 336.4 19 6146 1118 1118 420 325
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun.
Code* Word Phase Conductor Bare Neutral Messenger Weight
per 1000 ft. (lbs.)
Allowable
Ampacities+
Size
(AWG or kcmil)
Strand-
ing
Insul.
Thick.
(mils)
Size
(AWG or kcmil)
Strand-ing Rated
Strength
(lbs.)
XLP POLY XLP POLY
ACSR NEUTRAL-MESSENGER
Paludina 6 1 45 6 6/1 1190 109 109 85 70
Voluta 6 7 45 6 6/1 1190 114 114 85 70
Whelk 4 1 45 4 6/1 1860   164 115 90
Periwinkle 4 7 45 4 6/1 1860 172 172 115 90
Conch 2 7 45 2 6/1 2850 262 262 150 120
Neritina 1/0 7 60 1/0 6/1 4380 420 420 205 160
Cenia 1/0 9 60 1/0 6/1 4380 414 414 205 160
Runcina 2/0 7 60 2/0 6/1 5310 520 520 235 185
Triton 2/0 11 60 2/0 6/1 5310 512 512 235 185
Mursia 3/0 17 60 3/0 6/1 6620 635 635 275 215
Zuzara 4/0 18 60 4/0 6/1 8350 789 789 315 245
Limpet 336.4 19 80 336.4 18/1 8680 1167 1167 420 325
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun.
Code* Word Phase Conductor Bare Neutral Messenger Weight
per 1000 ft. (lbs.)
Allowable
Ampacities+
Size
(AWG)
Strand-
ing
Insul.
Thick.
(mils)
Size
(AWG)
Strand-ing Rated
Strength
(lbs.)
XLP POLY XLP POLY
ACSR REDUCED NEUTRAL-MESSENGER
Scallop 4 1 45 6 6/1 1190   142 115 90
Strombus 4 7 45 6 6/1 1190 151 151 115 90
Cockle 2 7 45 4 6/1 1860 228 228 150 120
Janthina 1/0 7 60 2 6/1 2853 366 366 205 160
Ranella 1/0 9 60 2 6/1 2853 360 360 205 160
Cavolinia 2/0 7 60 1 6/1 3550 453 453 235 185
Clio 2/0 11 60 1 6/1 3550 444 444 235 185
Aega 3/0 17 60 1/0 6/1 4380 549 549 275 215
Cerapus 4/0 18 60 2/0 6/1 5310 681 681 315 245
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun.
Code* Word Phase Conductor Bare Neutral Messenger Weight
per 1000 ft. (lbs.)
Allowable
Ampacities+
Size
(AWG)
Strand-
ing
Insul.
Thick.
(mils)
Equiv. Dia.
(AWG)++
Size
(kcmil)
Strand-ing Rated
Strength
(lbs.)
XLP POLY XLP POLY
6201 ALLOY REDUCED NEUTRAL-MESSENGER
Artemia 4 1 45 6 30.58 7 1110 135 135 115 90
Crab 4 7 45 6 30.58 7 1110 143 143 115 90
Solaster 2 7 45 4 48.69 7 1760 216 216 150 120
Sandcrab 1/0 7 60 2 77.47 7 2800 347 347 205 160
Echinus 1/0 9 60 2 77.47 7 2800 341 341 205 160
Fulgar 3/0 17 60 1/0 123.3 7 4460 519 519 275 215
Arca 4/0 18 60 2/0 155.4 7 5390 643 643 315 245
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).
+ Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC;emissivity 0.9; 2 ft./sec. wind in sun.
Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. 

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.