B-398 Aluminum Alloy 6201-T81 B-399 Concentrical-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
Product Description
We can supply this conductor according to different recognized standards, such as BS EN50182, IEC61089, ASTM B399DIN 48, customer special specification also can be satisfied.
The data sheets below show the most common standards, British standard and IEC standard.
IEC Sizes IEC 61089
Code Number | Stranding&wire diameter | Approx Overall diameter | Nominal | Approx. | Breaking Load | DC Resistance at 20 |
area | Weight | |||||
mm | mm | mm 2 | Kg/km | KN | Ohm/km | |
16 | 7/1.83 | 5.49 | 18.4 | 50.4 | 5.43 | 1.7896 |
25 | 7/2.29 | 6.86 | 28.8 | 78.7 | 8.49 | 1.1453 |
40 | 7/2.89 | 8.68 | 46 | 125.9 | 13.58 | 0.7158 |
63 | 7/3.63 | 10.9 | 72.5 | 198.3 | 21.39 | 0.4545 |
100 | 19/2.78 | 13.9 | 115 | 316.3 | 33.95 | 0.2877 |
125 | 19/3.10 | 15.5 | 144 | 395.4 | 42.44 | 0.2302 |
160 | 19/3.51 | 17.6 | 184 | 506.1 | 54.32 | 0.1798 |
200 | 19/3.93 | 19.6 | 230 | 632.7 | 67.91 | 0.1439 |
250 | 19/4.39 | 22 | 288 | 790.8 | 84.88 | 0.1151 |
315 | 37/3.53 | 24.7 | 363 | 998.9 | 106.95 | 0.0916 |
400 | 37/3.98 | 27.9 | 460 | 1268.4 | 135.81 | 0.0721 |
450 | 37/4.22 | 29.6 | 518 | 1426.9 | 152.79 | 0.0641 |
500 | 37/4.45 | 31.2 | 575 | 1585.5 | 169.76 | 0.0577 |
560 | 61/3.67 | 33 | 645 | 1778.4 | 190.14 | 0.0516 |
630 | 61/3.89 | 35 | 725 | 2000.7 | 213.9 | 0.0458 |
710 | 61/4.13 | 37.2 | 817 | 2254.8 | 241.07 | 0.0407 |
800 | 61/4.38 | 39.5 | 921 | 2540.6 | 271.62 | 0.0361 |
900 | 91/3.81 | 41.8 | 1036 | 2861.1 | 305.58 | 0.0321 |
1000 | 91/4.01 | 44.1 | 1151 | 3179 | 339.53 | 0.0289 |
1120 | 91/4.25 | 46.7 | 1289 | 3560.5 | 380.27 | 0.0258 |
1250 | 91/4.49 | 49.4 | 1439 | 3973.7 | 424.41 | 0.0231 |
BS EN 50182:2001
Code Name | Stranding&wire diameter | Approx Overall diameter | Total area | Weight | Breaking Load | DC Resistance at 20 | Current Rating |
mm | mm | mm 2 | Kg/km | KN | Ohm/km | A | |
Box | 7/1.85 | 5.55 | 18.8 | 51.4 | 5.55 | 1.748 | 93 |
Acacia | 7/2.08 | 6.24 | 23.9 | 64.9 | 7.02 | 1.3828 | 110 |
Almond | 7/2.34 | 7.02 | 30.1 | 82.2 | 8.88 | 1.0926 | 128 |
Cedar | 7/2.54 | 7.62 | 35.5 | 96.8 | 10.46 | 0.9273 | 132 |
Deodar | 7/2.77 | 8.31 | 42.2 | 115.2 | 12.44 | 0.7797 | 148 |
Fir | 7/2.95 | 8.85 | 47.8 | 130.6 | 14.11 | 0.6875 | 161 |
Hazel | 7/3.30 | 9.9 | 59.9 | 163.4 | 17.66 | 0.5494 | 184 |
Pine | 7/3.61 | 10.8 | 71.6 | 195.6 | 21.14 | 0.4591 | 204 |
Holly | 7/3.91 | 11.7 | 84.1 | 229.5 | 24.79 | 0.3913 | 222 |
Willow | 7/4.04 | 12.1 | 89.7 | 245 | 26.47 | 0.3665 | 233 |
Oak | 7/4.65 | 13.95 | 118.9 | 324.5 | 35.07 | 0.2767 | 272 |
Mulbery | 19/3.18 | 15.9 | 150.9 | 414.3 | 44.52 | 0.2192 | 319 |
Ash | 19/3.48 | 17.4 | 180.7 | 496.1 | 53.31 | 0.183 | 354 |
Elm | 19/3.76 | 18.8 | 211 | 579.2 | 62.24 | 0.1568 | 385 |
Poplar | 37/2.87 | 20.1 | 239.4 | 659.4 | 70.61 | 0.1387 | 414 |
Sycamore | 37/3.23 | 22.6 | 303.2 | 835.2 | 89.4 | 0.1095 | 487 |
Upas | 37/3.53 | 24.7 | 362.1 | 997.5 | 106.82 | 0.0917 | 527 |
Yew | 37/4.06 | 28.4 | 479 | 1319.6 | 141.31 | 0.0693 | 629 |
Totara | 37/4.14 | 29.42 | 498.1 | 1372.1 | 146.93 | 0.0666 | 640 |
Rubus | 61/3.50 | 31.5 | 586.9 | 1622 | 173.13 | 0.0567 | 716 |
Sorbus | 61/3.71 | 33.4 | 659.4 | 1822.5 | 194.53 | 0.0505 | 760 |
Araucaria | 61/4.14 | 37.3 | 821.1 | 2269.5 | 242.24 | 0.0406 | 842 |
Redwood | 61/4.56 | 41 | 996.2 | 2753.2 | 293.88 | 0.0334 | 920 |
- Next: AAC All Aluminum Conductor Sheep (30/3.71+7/3.71)
- Previous: AAAC (All Aluminum Alloy Conductor)
Contact us
Similar Or Related
-
Ccx-Wk PAS-W Sax-W Weather Resistant Black XLPE All Aluminum Alloy Conductor 20kv Cable
-
AAAC Overheadtransmission Line Cable Conductor Bare Conductor Aluminum Alloy Core
-
Bare Conductor AAA Aluminum Alloy Electrical Wires Cables Stranded
-
Bare Conductor AAAC Aluminum Alloy Stranded Conductor ASTM AWG
-
B-398 Aluminum Alloy 6201-T81 B-399 Concentrical-Lay-Stranded 6201-T81 Aluminum Alloy Conductors