Aluminum Insulated ABC Cable

Aluminum Insulated ABC Cable

Aluminum Insulated ABC Cable

ABC

Overhead

Low and Medium Voltage Cable

DC Cable

XLPE

No Jacket

Round Wire

Aluminum

ISO, CCC

ABC

Hongda

2 3 4 5

hongda

on The Drum or on The Pallent

10 16 25 35 50 70 95 120

Henan

8544492100

Product Description

Application of NFC 33-209 Standard ABC Cable

The power cables with cross-linked polyethylene (XLPE) insulation for overhead lines are designed for
electrical installations with alternating power networks with nominal voltage Uo/U 0.6/1 kV or in direct
power networks with maximum voltage according to land 0.9 kV.

The cables with supporting (bearing) zero conductors are used for building networks in city and urban
areas and the self-supporting type cables are for building distribution networks in these areas.

Cables for overhead installations may be used in different types of installations: on free hanging facades;
between posts; on fixed facades; trees and poles. Interception of forest areas without the need of
clearance and maintenance of openings is allowed.

Cables with supporting zero conductor, the whole bundle is suspended and carried by the supporting
conductor, which is made of aluminum compound.

Self-supporting construction, suspension and carrying of the whole bundle is done by the phase
insulated conductors.

Bundles can include one or two additional conductors for public lighting and control pair.

Standard of NFC 33-209 Standard ABC Cable

According to NF C 33-209

–Phase (main) M: Al stranded compacted or Non-compacted according to NF C 33-209
–Neutral(supporting)N: AL stranded according to NF C 33-209
–Additional for lighting R: Al stranded compacted or non-compacted according to NF C 33-209
Insulation of NFC 33-209 Standard ABC Cable

XLPE with min. 2.5% carbon black content

Construction of NFC 33-209 Standard ABC Cable

Cross Section of Conductor
(mm2)

Min.Nos. of Wires for Conductor
(mm)

Insulation Thickness
(mm)

Average Max. O.D.per Single-core
(mm)

Max.Conductor Resistance at 20ºC
(Ω/km)

Min Insulated Resistance at Rated Working Temperature
(MΩ.km)

Cable Tensile Breaking Force

2×10

6

1.00

6.5×13.0

3.08

0.0067

0.67

1650

2×16

6

1.20

8.0×16.0

1.91

0.0065

0.65

2512

2×25

6

1.20

9.4×18.8

1.2

0.0054

0.54

3762

2×35

6

1.40

11.0×22.0

0.868

0.0054

0.54

5177

2×50

6

1.40

12.3×24.6

0.641

0.0046

0.46

7011

2×70

12

1.40

14.1×28.2

0.443

0.004

0.4

10354

2×95

15

1.60

16.5×33.0

0.32

0.0039

0.39

13727

2×120

15

1.60

18.1×36.2

0.252

0.0035

0.35

17339

2×150

15

1.80

20.2×40.4

0.206

0.0035

0.35

21033

2×185

30

2.00

22.5×45.0

0.164

0.0035

0.35

26732

2×240

30

2.20

25.6×51.2

0.125

0.0034

0.34

34679

4×10

6

1.00

6.5×26.0

3.08

0.0067

0.67

1650

4×16

6

1.20

8.0×32.0

1.91

0.0065

0.65

2512

4×25

6

1.20

9.4×37.6

1.2

0.0054

0.54

3762

4×35

6

1.40

11.0×44.0

0.868

0.0054

0.54

5177

4×50

6

1.40

12.3×49.2

0.641

0.0046

0.46

7011

4×70

12

1.40

14.1×56.4

0.443

0.004

0.4

10354

4×95

15

1.60

16.5×66.0

0.32

0.0039

0.39

13727

4×120

15

1.60

18.1×72.4

0.252

0.0035

0.35

17339

4×150

15

1.80

20.2×80.8

0.206

0.0035

0.35

21033

4×185

30

2.00

22.5×90.0

0.164

0.0035

0.35

26732

4×240

30

2.20

25.6×102.4

0.125

0.0034

0.34

34679

Tags: , ,