NYY

Insulated

Stranded

Underground

Aluminum

PVC

PVC

Round Wire

Underground

ISO9001, CE, CCC

Jytop

1-5

1.5-800mm2

ISO,Ce

JYTOP

Reel or Drum

any Third party Pre-shipment inspection

Zhengzhou, China

8544492100

Product Description

1. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 70° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed:
Nominal cross section of conductor ≤ 300mm2: 160° C;
Nominal cross section of conductor >300mm2: 140° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For multi-core cable: Not less than 15 times of the diameter of cable

2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or in conduit, unable to bear external mechanical force.

3. Manufacturing Standards
DIN STANDARDS

Flame retardant PVC cable/wire is specially for flame retardant property, for it is hard to get fire and it can limit the continuous burning of calbe when it is on fire. It is classified as Class A, B, and C. Class A is the best one for this effect. Cables are strictly submitted to international and national standars as IEC, GB and BS, it has the national production license and had passed the national CCC certification. We offer various sizes from 1square mm to 10 square mm. PP laminating packing for export, and wooden packing is available.
1. conductor: copper
2. insulation: PVC

Nominal
cross-section

mm2

Conductor
Type

Upper limit
Of O.D.

mm

20ºC

Max. D.C.
resistance
at 20ºC
Ω/km

70ºC

Min. insulation resistance
at 70ºC
MΩ·km

Approx.
ampacity
A

Reference
weight
of cable
kg/km
1.5
1.5
2.5
2.5
4.0
4.0
6.0
6.0
10
16
25
35
50
70
95
120
150
185
240
300
400
1
2
1
2
1
2
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3.2
3.3
3.9
4.0
4.4
4.6
5.0
5.2
6.7
7.8
9.7
10.9
12..8
14.6
17.1
18.8
20.9
23.3
26.6
29.6
33.2
12.1
12.1
7.41
7.41
4.61
4.61
3.08
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.011
0.010
0.010
0.009
0.0085
0.0077
0.0070
0.0065
0.0065
0.0050
0.0050
0.0040
0.0045
0.0035
0.0035
0.0032
0.0032
0.0032
0.0032
0.0030
0.0028
25
25
34
34
44
44
58
58
79
111
146
180
282
281
344
397
456
519
592
685
799
20.0
21.5
31.8
34.8
46.8
50.3
66.5
71.0
116.0
180
277
375
536
706
977
1231
1503
1870
2457
3053
3948