All Aluminum Conductors Type & PVC Insulation (AAC/PVC)
Product Description
Standard: ASTM B230,B231,B232 and B399,ICEA S-61-402 and S-66-524
Capacity: 10000km/week
Delivery Length: accord with the request
Min.Order Qty : 1km
Application
Covered line Wire is used primarily for overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.
The code words as given apply to conventional polyethylene line wire.
Construction
The conductors are 1350-H19 aluminum ,6201-T81 Aluminum Alloy , or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene(HD) or crosslinked polyethylene(XLPE).
Specification
ASTM B-230, B-231, B-232 and B-399 ,ICEA S-61-402 and S-66-524 Standard
Code Name | Size | Stranding | Insulation Thickness | Overall Diameter |
Approx. Weight | Code Name | Size | Stranding | Insulation Thickness | Overall Diameter | Approx. Weight | ||||
XLPE | PE | XLPE | PE | ||||||||||||
AWG or MCM | – | mil | inch | lbs/1000ft | AWG or MCM | – | mil | inch | lbs/1000ft | ||||||
AAC 1350-H19 | ACSR | ||||||||||||||
Apple | 6 | Solid | 30 | .222 | 33.0 | 32.0 | Walnut | 6 | 6/1 | 30 | .258 | 49 | 47 | ||
Pear | 4 | Solid | 30 | .264 | 48.5 | 47.3 | Butternut | 4 | 6/1 | 30 | .303 | 71.8 | 70.0 | ||
Apricot | 4 | 7/w | 30 | .285 | 51.5 | 50.8 | Hickory | 4 | 7/1 | 30 | .309 | 81.6 | 79.8 | ||
Peach | 2 | 7/w | 45 | .373 | 87.1 | 84.0 | Pignut | 2 | 6/1 | 45 | .397 | 118.1 | 114.8 | ||
Quince | 1/0 | 7/w | 60 | .477 | 140.7 | 135.6 | Beech | 2 | 7/1 | 45 | .405 | 134.1 | 130.7 | ||
Orange | 2/0 | 7/w | 60 | .522 | 171.9 | 166.2 | Chestnut | 1 | 6/1 | 45 | .434 | 145.5 | 141.8 | ||
Fig | 3/0 | 7/w | 60 | .570 | 210.5 | 204.0 | Almond | 1/0 | 6/1 | 60 | .506 | 190.4 | 184.9 | ||
Olive | 4/0 | 7/w | 60 | .626 | 258.7 | 251.4 | Pecan | 2/0 | 6/1 | 60 | .554 | 234.2 | 227.9 | ||
Pomegranate | 4/0 | 19/w | 60 | .632 | 254.8 | 247.9 | Filbert | 3/0 | 6/1 | 60 | .607 | 288.5 | 281.4 | ||
Mulberry | 266.8 | 19/w | 60 | .692 | 313.5 | 305.8 | Buckeye | 4/0 | 6/1 | 60 | .666 | 356.5 | 348.5 | ||
Anona | 336.4 | 19/w | 60 | .766 | 387.6 | 378.8 | Hackberry | 266.8 | 18/1 | 60 | .711 | 354.8 | 346.8 | ||
Molles | 397.5 | 19/w | 75 | .852 | 469.2 | 457.4 | Alloy 6201-T81 | ||||||||
Huckleberry | 477.0 | 37/w | 75 | .921 | 550.0 | 537.5 | Hornbeam | 4 | 7/w | 30 | .310 | 62.1 | 60.1 | ||
Paw Paw | 556.5 | 37/w | 75 | .982 | 633.0 | 619.4 | Linden | 2 | 7/w | 45 | .406 | 96.1 | 93.3 | ||
Breadfruit | 636.0 | 61/w | 95 | 1.080 | 742.6 | 724.7 | Oilnut | 1/0 | 7/w | 60 | .518 | 166.1 | 160.0 | ||
Persimmon | 795.0 | 61/w | 95 | 1.187 | 910.0 | 890.0 | Waterash | 2/0 | 7/w | 60 | .567 | 203.3 | 196.4 | ||
Grapefruit | 1033.5 | 61/w | 95 | 1.327 | 1156.7 | 1133.8 | Shellbark | 3/0 | 7/w | 60 | .622 | 249.4 | 241.4 | ||
Note: | Planetree | 4/0 | 7/w | 60 | .683 | 307.3 | 298.1 | ||||||||
(1)Ampacity ratings based on 75°C conductor temperature 25°C ambient temperature elevation-sea level.
(2)Emissivity 0.91 coefficient of absorption 0.95. Thermal resistivity of covering -375°C-Cm2/Watt-CM.Wind speed 2ft./sec in sun.