All Aluminum Conductor (AAC)

All Aluminum Conductor (AAC)

All Aluminum Conductor (AAC)

LJ/LGJ

Bare

Stranded

Overhead

Aluminum

Bare

Round Wire

ISO9001

SABS

2000ton/Month

1km

Accord with The Request

SABS, ISO9001-2008, CQC Certificate, CE , SGS

Tianjin, Qingdao, Ningbo, Shanghai, Xiamen

L/C, D/P, D/a ,T/T, M/T, D/D, O/a, C.W.O, C.O.D, C

jiapu

Wooden Drum or Steel Drum

any one

HENAN CHINA

4101962331

Product Description

IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110 standard

ISO 9001 and ISO 14001. CE, SONCAP certificate

AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels.

Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)(3) aluminum conductor steel reinforced (ACSR)(4) anti-corrosion type ACSR(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)

2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.
1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM

(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.

Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.

Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)
Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Packing:
Standard export wooden drums

Code Name:

ASTM B231 Peachbell Rose Lris Pansey Poppy Aster Phlox Oxlip Valerian Sneezewort Laurel
Daisy Peony Tulip Daffodil Canna Goldentuft Syringa Cosmos Hyacinth Zinnia Dahlia Mistletoe Meadowsweet Orchid Heuchera Flag Verbena Nasturtium Violet Cattail Petunia Lilac Arbutus Snapdragon Cockscomb Goldenrod Magnolia Camellia Hawkweed Larkspur Bluebell Marigold Hawthorn Narcissus Columbine Carnation Gladiolus Coreopsis Jessamine Cowslip Lupine Trillium Bluebonnet
BS 215 Midge Aphis Gnat Weevil Mosquito Ladybird Ant Fly Bluebottle Earwing Grasshopper Clegg Wasp Beetle Bee Cricket Hornet Caterpillar Chafer Spider Cockroach Butterfly Moth Drone Locust Centipede Maybug Scorpion Cicada Tarantula
CSA C49 Anemone Cockscomb Magnolia Hawkweed Bluebell Marigold Hawthorn Narcissus Columbine Carnation Gladiolus Coreopsis Cowslip Sagebrush Lupine Bitterroo
DIN 48201 mm²: 16 25 35 50 70 95 120 150 185 240 300 400 500 625 800 1000
IEC 61089 mm²: 10 16 25 40 63 100 125 160 200 250 315 400 450 500 560 630 710 800 900 1000 1120 1250 1400 1500

Tags: , ,