Aerial Bundle Cable (ABC Cable) to ASTM Standard
Aerial Bundle Cable (ABC Cable) to ASTM Standard
abc cable
Phase Insulated with Bare Neutral
Solid or Stranded
Overhead
Aluminum or Aluminum Alloy or Aluminum & Steel
No
PE or XLPE
Round Wire
Overhead
ISO9001, CE, CCC
Jytop
Black, Red, Yellow, Blue, Brown, Green
95mm 120mm 150mm
0.6/1kv
2, 3, 4, 5
Aluminum or Aluminum Alloy
Henan
JYTOP
Packed in Reels
as per related ASTM standards
Zhengzhou, China
8544492100
Product Description
Aerial bundled cable ABC
Quadruplex Service Drop-Aluminum Conductor
Construction
Conductors are concentrically stranded, compressed 1350-H19 aluminum, insulated with either polyethylene or XLP crosslinked polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or ACSR. One conductor is manufactured with an extruded ridge for phase identification.
Standards
ASTM B-230, B-231, B-232, B-339 & ICEA S-76 -474
Code name |
Phase conductor | Bare neutral messenger | Weight per 1000 ft(lbs) |
Rating(Amps) | ||||||
Size AWG |
Strand | Insulation thickness (mls) |
Size AWG |
Strand | Breaking strength (lbs) |
XLP | POLY | XLP | POLY | |
AAC NEUTRAL-MESSNGER | ||||||||||
Clydesdale | 4 | Solid | 45 | 4 | 7 | 881 | 208 | 201.8 | 100 | 80 |
Pinto | 4 | 7/w | 45 | 4 | 7 | 881 | 223 | 207.9 | 100 | 80 |
Mustang | 2 | 7/w | 45 | 2 | 7 | 1,350 | 333 | 312.6 | 135 | 105 |
Criollo | 1/0 | 19/w | 60 | 1/0 | 7 | 1,990 | 529 | 504.5 | 180 | 140 |
Percheron | 2/0 | 19/w | 60 | 2/0 | 7 | 2,510 | 649 | 620.5 | 205 | 160 |
Hanoverian | 3/0 | 19/w | 60 | 3/0 | 19 | 3,310 | 799 | 765.6 | 235 | 185 |
Oldenburg | 4/0 | 19/w | 60 | 4/0 | 19 | 4,020 | 986 | 946.7 | 275 | 210 |
Lippizaner | 336.4 | 19/w | 80 | 336.4 | 19 | 6,146 | 1,546 | 1,519.2 | 370 | 280 |
ACSR NEUTRAL-MESSNGER | ||||||||||
Morochuca | 6 | Solid | 45 | 6 | 6/1 | 1,190 | 152 | 147.4 | 75 | 60 |
Chola | 6 | 7/w | 45 | 6 | 6/1 | 1,190 | 162 | 151.7 | 75 | 60 |
Morgan | 4 | Solid | 45 | 4 | 6/1 | 1,860 | 226 | 220 | 100 | 80 |
Hackney | 4 | 7/w | 45 | 4 | 6/1 | 1,860 | 241 | 226.1 | 100 | 80 |
Palomino | 2 | 7/w | 45 | 2 | 6/1 | 2,850 | 362 | 342.6 | 135 | 105 |
Costena | 1/0 | 19/w | 60 | 1/0 | 6/1 | 4,380 | 575 | 550.6 | 180 | 140 |
Grullo | 2/0 | 19/w | 60 | 2/0 | 6/1 | 5,310 | 707 | 678.7 | 205 | 160 |
Suffolk | 3/0 | 19/w | 60 | 3/0 | 6/1 | 6,620 | 872 | 838.9 | 235 | 185 |
Appaloosa | 4/0 | 19/w | 60 | 4/0 | 6/1 | 8,350 | 1079 | 1039.2 | 275 | 210 |
Bronco | 336.4 | 19/w | 80 | 336.4 | 18/1 | 8,580 | 1613 | 1568.2 | 370 | 280 |
Gelding | 336.4 | 19/w | 80 | 4/0 | 6/1 | 8,350 | 1548 | 1494.3 | 370 | 280 |
Code name |
Phase conductor | Bare neutral messenger | Weight per 1000 ft(lbs) |
Rating(Amps) | ||||||
Size AWG |
Strand | Insulation thickness (mls) |
Size AWG |
Strand | Breaking strength (lbs) |
XLP | POLY | XLP | POLY | |
6201 ALLOY NEUTRAL-MESSENGER | ||||||||||
Bay | 6 | Solid | 45 | 6 | 7 | 1,110 | 145 | 140.0 | 75 | 60 |
French Coach | 6 | 7/w | 45 | 6 | 7 | 1,110 | 155 | 144.3 | 75 | 60 |
German Coach | 4 | Solid | 45 | 4 | 7 | 1,760 | 214 | 208.3 | 100 | 80 |
Arabian | 4 | 7/w | 45 | 4 | 7 | 1,760 | 229 | 214.4 | 100 | 80 |
Belgian | 2 | 7/w | 45 | 2 | 7 | 2,800 | 344 | 323.1 | 135 | 105 |
Shetland | 1/0 | 19/w | 60 | 1/0 | 7 | 4,460 | 546 | 521.1 | 180 | 140 |
Thoroughbred | 2/0 | 19/w | 60 | 2/0 | 7 | 5,390 | 670 | 641.5 | 205 | 160 |
Trotter | 3/0 | 19/w | 60 | 3/0 | 7 | 6,790 | 825 | 791.8 | 235 | 185 |
Walking | 4/0 | 19/w | 60 | 4/0 | 7 | 8,560 | 1019 | 979.7 | 275 | 210 |