ACSR Conductors with Asem DIN IEC CSA
ACSR Conductors with Asem DIN IEC CSA
16/2.5
Construction, Overhead, Power Station
High Voltage Cable
AC Cable
Bare
No
No
Aluminum Conductors Steel Reinforced
ISO, CCC, CE, UL, VDE
ACSR
Jinshui
JIN SHUI
Wooden Drun
Rabbit
China
8544492100
Product Description
Product Description
Specifications
Aluminum conductor steel reinforced.
Biggest ACSR conductor supplier for China State Grid..
ACSR(Aluminum Conductor Steel Reinforced) is widely used in the overhead power distribution system of our country.
We can supply this conductor according to different recognized standards,such as IEC61089,BS215,ASTM B232,CSA C49,DIN48204,JIS C3110, customer special specification also can be satisfied.
The data sheets below show the most common standards,British standard.
British Sizes BS EN 50182:2001
STRANDARD:
BS 215 PART 2
code name: mole ,aquirrel ,gophel , weasel , fox , ferret , rabbit , minik , skunk , beaver , horse , racoon , otter , cat , hare , dog , coyote
ASTM B232
code name: turkey , swan , swanate , sparrow, robin , raven , quail , pigeon , penguin , waxwing , partridge , ostrich , merlin ,linner , oriole , chickadee , brant , ibis ,lark ,pelican , flicker , hawk ,hen ,osprey , parakeet , dove ,eagle ,peacock , squab , wood duck , teal , rook , grosbeak , swift ,scoter
Specifications
Aluminum conductor steel reinforced.
Biggest ACSR conductor supplier for China State Grid..
ACSR(Aluminum Conductor Steel Reinforced) is widely used in the overhead power distribution system of our country.
We can supply this conductor according to different recognized standards,such as IEC61089,BS215,ASTM B232,CSA C49,DIN48204,JIS C3110, customer special specification also can be satisfied.
The data sheets below show the most common standards,British standard.
British Sizes BS EN 50182:2001
STRANDARD:
BS 215 PART 2
code name: mole ,aquirrel ,gophel , weasel , fox , ferret , rabbit , minik , skunk , beaver , horse , racoon , otter , cat , hare , dog , coyote
ASTM B232
code name: turkey , swan , swanate , sparrow, robin , raven , quail , pigeon , penguin , waxwing , partridge , ostrich , merlin ,linner , oriole , chickadee , brant , ibis ,lark ,pelican , flicker , hawk ,hen ,osprey , parakeet , dove ,eagle ,peacock , squab , wood duck , teal , rook , grosbeak , swift ,scoter
Code Number | Stranding& Wire Diameter | Approx | Sectional Area | ApproxWeight | Breaking Load | DC Resistance | |||
Overall | |||||||||
Al | Steel | Diameter | Al | Steel | Total | ||||
mm | mm | mm | mm 2 | mm 2 | mm 2 | Kg/km | KN | Ohm/km | |
16 | 6/1.84 | 1/1.84 | 5.53 | 16 | 2.67 | 18.7 | 64.6 | 6.08 | 1.7934 |
25 | 6/2.30 | 1/2.30 | 6.91 | 25 | 4.17 | 29.2 | 100.9 | 9.13 | 1.1478 |
100 | 6/4.61 | 1/4.61 | 13.8 | 100 | 16.7 | 117 | 403.8 | 34.33 | 0.2869 |
125 | 18/2.97 | 1/2.97 | 14.9 | 125 | 6.94 | 132 | 397.9 | 29.17 | 0.2304 |
160 | 18/3.36 | 1/3.36 | 16.8 | 160 | 8.89 | 169 | 509.3 | 36.18 | 0.18 |
250 | 22/3.80 | 7/2.11 | 21.6 | 250 | 24.6 | 275 | 880.6 | 68.72 | 0.1154 |
400 | 54/3.07 | 7/3.07 | 27.6 | 400 | 51.9 | 452 | 1510.3 | 123.04 | 0.0723 |
450 | 54/3.26 | 7/3.26 | 29.3 | 450 | 58.3 | 508 | 1699.1 | 138.42 | 0.0643 |
500 | 54/3.43 | 7/3.43 | 30.9 | 500 | 64.8 | 565 | 1887.9 | 153.8 | 0.0578 |
560 | 54/3.63 | 19/2.18 | 32.7 | 560 | 70.9 | 631 | 2103.4 | 172.59 | 0.0516 |
630 | 54/3.85 | 19/2.31 | 34.7 | 630 | 79.8 | 710 | 2366.3 | 191.77 | 0.0459 |
710 | 54/4.09 | 19/2.45 | 36.8 | 710 | 89.9 | 800 | 2666.8 | 216.12 | 0.0407 |
800 | 72/3.76 | 7/2.51 | 37.6 | 800 | 34.6 | 835 | 2480.2 | 167.41 | 0.0361 |
900 | 72/3.99 | 7/2.66 | 39.9 | 900 | 39.9 | 939 | 2790.2 | 188.33 | 0.0321 |