ABC Aerial Bundle Cable for Overhead Transmission Line

ABC Aerial Bundle Cable for Overhead Transmission Line

ABC Aerial Bundle Cable for Overhead Transmission Line

360x15mm

Construction, Underground, Industrial, Power Station

1kv

DC Cable

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC, VDE

ABC

Jytop

Max. DC Resistance @ 20 Degree 0.387 Ohm/Km

Max. DC Resistance @ 20 Degree 4.61 Ohm/Km

Max. DC Resistance @ 20 Degree 3.08 Ohm/Km

Max. DC Resistance @ 20 Degree 1.83 Ohm/Km

Max. DC Resistance @ 20 Degree 1.15 Ohm/Km

JYTOP

Packed in Reels

as per popular standards or clients's requirement

Zhengzhou, China

8544492100

Product Description

ABC Aerial Bundle Cable for Overhead transmission Line

Specification: Aerial Bundle Cable
Standard: IEC228, IEC209, IEC60502
Voltage: 0.6/1 KV
Conductor: Aluminum conductor, aluminum alloy conductor, AAC, ACSR, AAAC
Insulation: HDPE, XLPE, PVC
Application: New type of Aerial Bundle Cable for Power transmission, used for rebuilding of urban and forest regions, which can improve safety and reliance of electrified wire netting.

ABC aerial bundle cable; Service Drop Cable
1 The basic construction is as follows:
three power cores consisting of standard aluminum conductors, insulated with XLPE
insulation + One sheath lighting aluminum conductor with XLPE insulation (optional) + One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanized steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.
2 Application
To be used at cottages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for crosslinked polyethylene (XLPE) insulated conductors.
It meets or exceeds the following specifications:
2.1. Aluminum Wire, 1350-H19 for Electrical Purposes.
2.2. Aluminum Conductors, Concentric-Lay-Stranded.
2.3. Aluminum Conductor, Concentric-Lay-Stranded, Coated Steel Reinforced(ACSR)
2.4. Concentric-Lay-Stranded 6201-T81 Conductors
2.5. Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
It meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

3.Types (ABC Aerial cable with ACSR messenger Core)

Nominal cross-section area (mm2) Conductor structure Insulation material Insulation Thickness (mm) Approx. Overall Diameter (mm) Approx.weight (kg/km) Packing meters per drum
Phase (Compacted AL) Neutral(bare ACSR)
(No./mm) Aluminum (No./mm) Steel (No./mm)
1×16+16 7/1.72 6/1.72 1/1.72 XLPE 1.2 12.5 121.9 250-4000m
1×25+25 7/2.15 6/2.15 1/2.15 1.2 14.9 182.2 250-4000
1×35+35 7/2.54 6/2.54 1/2.54 1.4 17.5 254.7 250-3500m
1×70+70 19/2.15 12/2.15 7/2.15 1.4 23.6 382.2 250-3000m
1×95+95 19/2.54 12/2.54 7/2.54 1.6 27.6 528.2 250-3000m
2×16+16 7/1.72 6/1.72 1/1.72 1.2 14.2 187.6 250-4000m
2×25+25 7/2.15 6/2.15 1/2.15 1.2 16.7 273.8 250-3500m
2×35+35 7/2.54 6/2.54 1/2.54 1.4 19.7 386.9 250-3500m
2×70+70 19/2.15 12/2.15 7/2.15 1.4 26.1 617.2 250-3000m
2×95+95 19/2.54 12/2.54 7/2.54 1.6 30.5 850.9 250-3500m
3×70+70 19/2.15 12/2.15 7/2.15 1.4 29.7 1024.3 250-3000m
3×95+95 19/2.54 12/2.54 7/2.54 1.6 34.6 1413.7 250-3000m

Parameter of ABC cable

Code Word Phase Conductor Neutral Complete Cable DC
Resistance
at 20°C
(ohm/kft)
Inductive
Reactance
(ohm/kft)
Ampacity*
(90°C)
Size
(# of wires)
Insulation
Thickness
(inch)
Size
(Stranding)
Overall
Diameter
(inch)
Cable
Weight
(lb/kft)
Shepherd/XLP 6 (7) 0.045 6 (6/1) 0.47 77 0.661 0.029 95
Retriever/XLP 6 (7) 0.060 6 (6/1) 0.50 85 0.661 0.031 95
Terrier/XLP 4 (7) 0.045 4 (6/1) 0.57 116 0.416 0.028 125
Yorkshire/XLP 4 (7) 0.060 4 (6/1) 0.60 125 0.416 0.029 125
Chow/XLP 2 (7) 0.045 2 (6/1) 0.70 177 0.261 0.027 165
Labrador/XLP 1 (19) 0.060 1 (6/1) 0.81 231 0.207 0.027 180
Bloodhound/XLP 1/0 (7) 0.060 1/0 (6/1) 0.89 285 0.164 0.028 220
Bull/XLP 1/0 (19) 0.060 1/0 (6/1) 0.89 285 0.164