AAC with DIN48201 Standard

AAC with DIN48201 Standard

AAC with DIN48201 Standard

16mm2, 25mm2, 35mm2, 50mm2

Bare

Solid

Overhead

Aluminum

ISO9001, CE

SABS

2000ton/Month

SABS, ISO9001-2008, CQC Certificate, CE , SGS

Accord with The Request

1km

L/C, D/P, D/a ,T/T, M/T, D/D, O/a, C.W.O, C.O.D, C

Tianjin, Qingdao, Ningbo, Shanghai, Xiamen

xinsheng

Export Wooden Drums

Any Standard

China

Product Description

IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182, JIS C3110 standard

ISO 9001 and ISO 14001. CE, SONCAP certificate

AAC, AAAC, ACSR, AACSR&ACAR conductor widely used in power transmission lines with various voltage levels.

Since they have such good characteristics as simple structure, convenient installation and maintenance, low cost for the line, large transmission capacity and are also suitable for laying across rivers and valleys where special geographical teatures exist.
1. Specification:
(1) all aluminium conductor (AAC)
(2) all aluminimum alloy conductor(AAAC)(3) aluminum conductor steel reinforced (ACSR)(4) anti-corrosion type ACSR(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)
(6)rear earth aluminimum conductor steel reinforced(ACSR/RE)
(7)aluminimum conductor aluminimum alloy reinforced(ACAR)

2. Elative manufacturing standards: IEC83, IEC1089, 31, B232, BS215, DIN48204.

1). Standard: IEC61089, BS215 part2, ASTM B232, DIN48204, BS EN50182.
2). Specification: ACSR is composed by bare concentric-lay-stranded galvanized steel wire(s) with aluminum wires surrounded by one or more layers of helically. Greased ACSR can also be supplied.
3). Application: ACSR is widely used in overhead electric power transmission and distribution lines with various voltage levels.

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM

(AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228
(AAAC) Conductor as per ASTM-B-399-1992
(AAAC) Conductor as per BS-3242-1970
(AAAC) Conductor IS: 398-IV-1994
(ACSR) as per ASTM-B-233-1992
(AAC) as per BS-215-1-1970
(AAC) as per IS-398-1: 1976
(AAC) as per ASTM-B-231-1990
(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992
(ACSR) BS-215-II-1970
(AACSR) as per IEC-1089-1191
AAC(All aluminum conductor) are suited for overhead power line.
We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, ASTM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.
ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.

Applications:
Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.
Construction:
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corrosion or infusion of the complete cable with grease.

Specifications:
ACSR bare conductor meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-341 Aluminum-clad Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW)
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ)
B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR)

Notes:
Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.
Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

Packing:
Standard export wooden drums

Code Number Calculated Cross Section No./Dia.of Stranding Wire Overall Diameter Linear Mass Calculated Breaking Load Max.D.C. Resistance at 20ºC
mm² mm² mm mm kg/km daN Ω/km
16 15.89 7/1.70 5.1 44 290 1.8018
25 24.25 7/2.10 6.3 67 425 1.1808
35 34.36 7/2.50 7.5 94 585 0.8332
50 49.48 7/3.00 9.0 135 810 0.5786
50 48.36 19/1.80 9.0 133 860 0.5950
70 65.82 19/2.10 10.5 181 1150 0.4371
95 93.27 19/2.50 12.5 256 1595 0.3084
120 117.00 19/2.80 14.0 322 1910 0.2459
150 147.10 37/2.25 15.2 406 2570 0.1960
185 181.60 37/2.50 17.5 501 3105 0.1587
240 242.54 61/2.25 20.2 670 4015 0.1191
300 299.43 61/2.50 22.5 827 4850 0.0965
400 400.14 61/2.89 26.0 1105 6190 0.0722
500 499.83 61/3.23 29.1 1381 7600 0.0578
625 626.20 91/2.96 32.6 1733 9690 0.04625
800 802.10 91/3.35 36.8 2219 12055 0.0361
1000 999.71 91/3.74 41.1 2766 14845 0.0290

Workshop:

Shipment:

Customer:

Certification:

FAQ:
1. How many years has Henan Jiapu Cable Group been in production?
Founded in October 1998 by Mr. Gu, our facility has three separate manufacturing workshops within its 100,000-sq.-ft. building. In 2012, we operates in a new 666,000 sq. foot state-of-the-art facility in Xiaodian Industry Park.,Xinxiang, Henan ,China

2. What kinds of products does Jiapu Cable manufacture?
1)Bare Conductor ,such as AAC,AAAC,ACSR,ACAR,AACSR,ACSR/AW and so on;
2)Aerial Bundled Cable (1kV-35kV ),such as Duplex,Triplex,Quadruplex Drop Wires and so on;
3)PVC Insulated (Flexible ) Wire ;
4) PVC Insulated and Sheathed (Armoured) Power Cable;
5)Low, Medium, High Voltage (1kV-220kV) XLPE Insulated (Armoured) Power Cable;
6)Welding Cable, Control Cable, Concentric Cable, Rubber Sheathed Cable and so on;

3. What kind of certifications do you have?
SABS, CE, ISO9001-2000, SGS

4.Which markets do you involve mainly in?
Our products have been exported mainly to Africa, Middle East, South-east Asia, South America,Central America,North America, Europe ,Australia, etc.

5. Which standards do you comply with when you produce the electrical wires and cables ?
We are able to produce electrical wires and cables based on GB, JB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA, etc. Meanwhile, we can design and manufacture the cables according to the samples and technical specification the customer supply.

6. What is the min.order quantity ?
It depends on the type and size of electrical wires and cables. For some small electrical wires, 100 meters can be accepted .But for the power cables with medium or high voltage, that should comply with the property of installed equipments. Anyhow,we will try our best to solve the problem and meet with the requirement If you have special request.

7. What is the production capacity per week or per month ?
For the bare conductor, we can finish 3000 tons within one month. For power cables, that depends on the type and size. The total output value per month is approx. USD3,000,000.00 for insulated aluminum cables and that is approx. USD8,000,000.00 for insulated copper cables.

8. Do you supply the customers with installation service in foreign country ?
We don’t have professional installation teams in foreign country.But if that is necessary, we will recommend our partners to cooperate with you.

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.