0.6/1kv Annealed Copper Wire XLPE Insulated Armour Cable Flame Retardant PVC Sheath Tray Cable
Product Description
Tray cable
Product Standard
This product is manufactured according to GB/T12706.1, equivalent to IEC60502.1. Or BS, DIN, ICEA standard as customer request.
Application
The product is suitable for power transmission and distribution lines with rated power frequency voltage up to and including 0.6/1KV.
Operating Performance
1). Rated power frequency voltage Uo/U: 0.6/1KV.
2). Max. Permissible continuous operating temperature of conductor: 90ºC
3). Max. Short-circuit temperature of the conductor shall not exceed: (5S maximum duration) 250ºC
4). The ambient temperature under installation should not below 0ºC
5). The bending radius of a cable should not be less than 15 times of the cable diameter.
6). The test voltage (A.C.): 3.5kV/5min.
7). The flame-retardant properties of cable comply with grade A, B, C of GB/T19666-2005 or IEC60332.
Construction:
Conductor: Solid or stranded copper, aluminum
Insulation: Cross-linked polyethylene( XLPE or PVC)
Circuit Identification: The insulation shall be red, black
Filler: Polypropylene lament with lapped binding tape
Inner Sheath: Polyvinyl chloride (Black)
Armor: Galvanized steel wire
Core-covering: Binding tape
Outer Sheath: Polyvinyl chloride (Black)
Package: Wooden Drum Package or Iron-wooden drum
Type and Name:
Type | Designation | Applications |
YJV | Copper conductor, XLPE insulated, PVC sheathed power cable | For laying indoors, in a tunnel or cable trench, unable to bear external mechanical forces. The single-core cable is not allowed to lay in the magnetic duct. |
YJLV | Aluminum conductor,XLPE insulated,PVC sheathed power cable | |
YJY | Copper conductor, XLPE insulated,PE sheathed power cable | |
YJLY | Aluminum conductor, XLPE insulated, PE sheathed power cable | |
YJV22 | Copper conductor, XLPE insulated, steel tape armored, PVC sheathed power cable | For laying indoors, in a tunnel in cable trench, or direct in ground, able to bear external mechanical forces.Single-core cable is not allowed to lay in the magnetic duct. |
YJLV22 | Aluminum conductor, XLPE insulated, steel tape armored, PVC sheathed power cable | |
YJV23 | Copper conductor, XLPE insulated, steel tape armored, PE sheathed power cable | |
YJLV23 | Aluminum conductor,XLPE insulated, steel tape armored, PE sheathed power cable | |
YJV32 | Copper conductor,XLPE insulated, steel wire armored, PVC sheathed power cable | For laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force. |
YJLV32 | Aluminum conductor,XLPE insulated, steel wire armored, PVC sheathed power cable | |
YJV33 | Copper conductor,XLPE insulated, steel wire armored, PE sheathed power cable | |
YJLV33 | Aluminum conductor,XLPE insulated, steel wire armored, PE sheathed power cable |
Specification:
Type | No. of cores | Nom. Cross-section of conductor (mm2) |
|
Copper conductor | Aluminum conductor | ||
YJV YJY | – | 1 | 1.5-800 |
– | YJLV YJLY | 2.5-800 | |
YJV22 YJV23 | YJLV22 YJLY23 | 10-800 | |
YJV YJY | – | 2 | 1.5-300 |
– | YJLV YJLY | 2.5-300 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4.0-300 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-300 | |
YJV YJY | – | 3 | 1.5-400 |
– | YJLV YJLY | 2.5-400 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4.0-400 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
YJV YJY | – | 4 | 1.5-400 |
– | YJLV YJLY | 2.5-400 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4.0-400 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
YJV YJY | – | 3+1 | 1.5-400 |
– | YJLV YJLY | 4.0-400 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4. 0-400 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
YJV YJY | – | 5 | 1.5-400 |
– | YJLV YJLY | 2.5-400 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4.0-400 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
YJV YJY | – | 4+1 | 1.5-400 |
– | YJLV YJLY | 4.0-400 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4. 0-400 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
YJV YJY | – | 3+2 | 1.5-400 |
– | YJLV YJLY | 4.0-400 | |
YJV22 YJV23 | YJLV22 YJLY23 | 4. 0-400 | |
YJV32 YJV33 | YJLV32 YJLY33 | 10-400 | |
The armoured single core cables are used for D.C. system only. As for A.C. system,non-magnetic armour material should be used, or a magnetic isolation should be applied. |
- Next: H07rnf H05rnf H07rrf H07rrf Cable Flexible Copper Conductor Epr Insulation CPE Sheathed Cable with CE Certificate
- Previous: UL Listed and MSHA Certificate 2kv Type W G Gc Flexible Mining Cable
Contact us
Similar Or Related
-
0.6/1kv 800 Series 2*8AWG Aluminum Alloy Conductor XLPE Insulation Concentric Cable
-
0.6/1 Kv Al/XLPE 3*150+150mm ABC Cable Quadruplex Overhead Cable
-
0.6/1 Kv Al/XLPE 2*50+50mm2 Service Drop ABC Cable Triplex Cable
-
0.6/1kv Annealed Copper Wire XLPE Insulated Armour Cable Flame Retardant PVC Sheath Tray Cable