660/1100V Voltage Vvg Vvgng Vvgng-Frls Copper Power Cable for Russian

660/1100V Voltage Vvg Vvgng Vvgng-Frls Copper Power Cable for Russian

660/1100V Voltage Vvg Vvgng Vvgng-Frls Copper Power Cable for Russian

vv

YJV

ISO, CCC

Bare Copper Wire

Round Wire

PVC

XLPE

DC & AC

Low and Medium Voltage Cable

Construction, Underground, Industrial, Power Station

OEM/Hongda

in Drum or in Coil

3*1.5 3*2.5 3*4 4*1.5 4*2.5 4*4 5*1.5 5*2.5 5*4

Henan

8544492100

Product Description

Application

 

Construction:
1. Conductor – copper, single or multiwire, round- or sector-shaped, 1 or 2 class as per GOST 22483. 
2. Insulation – PVC. Insulated multiconductor cable conductors carry identification coloring. Neutral conductor insulation is blue. Grounding conductor insulation is in two colors (yellow-green). 
3. Twisting – Insulated conductors of two-, three-, four-, and five- conductor cables are twisted. Two conductor cables feature conductors of the same area. Three-, four-, and five- conductor cables feature all the conductors of the same area or one conductor (ground or neutral one ) of a smaller area. 
4. Jacket – PVC, VVng cables are sheathed with flameretardant PVC.

Application:
These cables are intended for distributing electric power in fixed installations rated for nominal alternating voltages of 0.66 KV and 1 KV 50 Hz. They are meant for laying inside both dry and wet industrial premises on special trestles, in assemblies as well as for laying outdoors. Cables are not recommended for burying in trenches.
VVG cables are flameretardant if laid individually.
VVGng cables are flameretardant if laid in bunches.

       
Mobile: +86 18339931106      
 

Technical details:
Type of climatization UHL, allocation category – 1 and 5 as per GOST 15150-69.
Operating temperature range………………………-500 to +500
Relative humidity of air…………………………..up to 98%
Cables shall be laid and installed without preheating at temperatures not lower than …-15
Minimum bending radius when laid: VVG single conductor cables………………………… 10 outer diameters
VVGng single conductor cables………………………….15 outer diameters
Multiconductor cables………………………………..7.5 outer diameters
Rated frequency…………………………………50 Hz
Testing alternating current voltage 50 Hz
For 0.66 KV……………………3 KV
For 1 KV……………………………………….3.5 KV
Continuously permissible conductor operating heating temperature…..…+70

Construction
 
1. Copper conductor
2. XLPE insulation
3. PP filling material
4. PVC outer sheath black
 
Properties
 
Max. admissible conductor temperature:  90 °C
Service temperature: – 20 … + 90 °C
Min. Laying temperature: – 5 °C
Min. bending  radius:
Multicourse: 12 x D
Single co C1: 15 x D
Flame C1tardant acc. to (IEC 60332-1)
 
Technical Specification
 
Conductor Type:
Class 1: rigidd conductor          Class 2, muliti-stranded conductor     
 
Cable Structure Data

Number of co C1s and size Insulation thickness Outer sheath thickness Outer diameter Weight of cable
mm2 mm mm D approx. mm approx. kg/km
1 x 16 C2 0,7 1,4 9,5 215
1 x 25 C2 0,9 1,4 11,0 310
1 x 35 C2 0,9 1,4 12,0 410
1 x 50 C2 1,0 1,4 13,5 540
1 x 70 C2 1,1 1,4 15,5 745
1 x 95 C2 1,1 1,5 17,5 1010
1 x 120 C2 1,2 1,5 19,0 1250
1 x 150 C2 1,4 1,6 21,0 1535
1 x 185 C2 1,6 1,6 23,5 1910
1 x 240 C2 1,7 1,7 26,0 2470
1 x 300 C2 1,8 1,8 28,5 3080
1 x 400 C2 2,0 1,9 32,0 3995
2 x 1,5 C1 0,7 1,8 10,5 145
2 x 2,5 C1 0,7 1,8 11,0 180
2 x 4 C1 0,7 1,8 12,0 225
2 x 6 C2 0,7 1,8 13,5 310
2 x 10 C2 0,7 1,8 15,0 420
2 x 16 C2 0,7 1,8 17,5 600
2 x 25 C2 0,9 1,8 20,5 880
2 x 35 C2 0,9 1,8 23,0 1160
3 x 1,5 C1 0,7 1,8 10,5 165
3 x 2,5 C1 0,7 1,8 11,5 210
3 x 4 C1 0,7 1,8 12,5 265
3 x 6 C2 0,7 1,8 14,5 370
3 x 10 C2 0,7 1,8 16,0 515
3 x 16 C2 0,7 1,8 18,5 750
3 x 25 C2 0,9 1,8 21,5 1110
3 x 35 C2 0,9 1,8 24,5 1475
3 x 50 C2 1,0 1,8 26,5 1865
3 x 70 C2 1,1 1,9 31,5 2680
3 x 95 C2 1,1 2,0 35,5 3600
3 x 120 C2 1,2 2,1 39,5 4515
3 x 150 C2 1,4 2,3 44,0 5555
3 x 185 C2 1,6 2,4 48,5 6930
3 x 240 C2 1,7 2,6 55,0 9010
3 x 300 C2 1,8 2,8 61,0 11195
4 x    1,5 C1 0,7 1,8 11,5 190
4 x 2,5 C1 0,7 1,8 12,5 245
4 x 4 C1 0,7 1,8 13,5 320
4 x 6 C2 0,7 1,8 15,5 445
4 x 10 C2 0,7 1,8 17,0 635
4 x 16 C2 0,7 1,8 20,0 930
4 x 25 C2 0,9 1,8 23,5 1390
4 x 35 C2 0,9 1,8 26,5 1850
4 x 50 C2 1,0 1,9 30,5 2450
4 x 70 C2 1,1 2,0 34,5 3410
4 x 95 C2 1,1 2,1 39,5 4640
4 x 120 C2 1,2 2,3 44,0 5780
4 x 150 C2 1,4 2,4 48,5 7075
4 x 185 C2 1,6 2,6 54,5 8965
4 x 240 C2 1,7 2,8 61,0 11510
4 x 300 C2 1,8 3,0 67,5 14370
5 x 1,5 C1 0,7 1,8 12,5 225
5 x 2,5 C1 0,7 1,8 13,5 290
5 x 4 C1 0,7 1,8 14,5 380
5 x 6 C2 0,7 1,8 17,0 540
5 x 10 C2 0,7 1,8 19,0 775
5 x 16 C2 0,7 1,8 21,5 1135
5 x 25 C2 0,9 1,8 27,0 1780
7 x 1,5 C1 0,7 1,8 13,5 275
7 x 2,5 C1 0,7 1,8 14,5 360
12 x 1,5 C1 0,7 1,8 17,0 450
12 x 2,5 C1 0,7 1,8 19,0 595
19 x 1,5 C1 0,7 1,8 20,0 615
19 x 2,5 C1 0,7 1,8 22,0 850
24 x 1,5 C1 0,7 1,8 23,0 785
24 x 2,5 C1 0,7 1,8 25,5 1050
27 x 1,5 C1 0,7 1,8 23,5 840
27 x 2,5 C1 0,7 1,8 26,0 1135
37 x 1,5 C1 0,7 1,8 26,0 1060
37 x 2,5 C1 0,7 1,8 29,0 1485

                  

        
     

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.