500mm2 Conductor Oak AAAC 100mm2 Wasp ACSR Aluminum
Product Description
Application:
Aluminum alloy conductor can replace some part of AAC or ACSR conductor used in overhead power transmission and distribution lines;Continuously use temperature can reach 90 °C. The use of heat-resisting aluminum alloy conductor temperature can reach 150 °C andabove.It has high current carrying capacity.The anti-corrosion performance is good.Heat treatment type magnesium aluminum silicon alloy has good tensile strength, and the conductivity is only about 10% lower than that of aluminum wire, can be used in large span transmission lines.
Standards
GB/T1179-2008
IEC61089-1991
IEC.ASTM,DIN,BS
Construction
Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); or aluminum-clad (AW) – please see our ACSR/AW spec for more information. Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease.
Parameter of Aluminum conductor
Code word | Size (kcmil) |
Strand -ing |
Diameter (ins.) |
Weight per 1000 ft. (Lbs) |
Rated strength (Lbs) | Resistance /1000 ft. |
Allowable ampacity+ (Amps) | ACSR with equiv.diam. |
Approx EC cond. with equivalent resistance | |||
Indivi- dual wire |
Complete conductor | DC at 20ºC |
AC at 75ºC |
Size | Stranding (AL/STL) |
|||||||
Akron | 30.58 | 7 | 0.0661 | 0.198 | 28.5 | 1110 | .659 | .785 | 107 | 6 | 6/1 | 6 |
Alton | 48.69 | 7 | 0.0834 | 0.250 | 45.4 | 1760 | .414 | .493 | 143 | 4 | 6/1 | 4 |
Ames | 77.47 | 7 | 0.1052 | 0.316 | 72.2 | 2800 | .260 | .310 | 191 | 2 | 6/1 | 2 |
Azusa | 123.3 | 7 | 0.1327 | 0.398 | 115.0 | 4460 | .163 | .195 | 256 | 1/0 | 6/1 | 1/0 |
Anaheim | 155.4 | 7 | 0.1490 | 0.447 | 144.9 | 5390 | .130 | .154 | 296 | 2/0 | 6/1 | 2/0 |
Amherst | 195.7 | 7 | 0.1672 | 0.502 | 182.5 | 6790 | .103 | .123 | 342 | 3/0 | 6/1 | 3/0 |
Alliance | 246.9 | 7 | 0.1878 | 0.563 | 230.2 | 8560 | .0816 | .0973 | 395 | 4/0 | 6/1 | 4/0 |
Butte | 312.8 | 19 | 0.1283 | 0.642 | 291.7 | 11000 | .0644 | .0769 | 460 | 266.8 | 26/7 | 266.8 |
Canton | 394.5 | 19 | 0.1441 | 0.720 | 367.9 | 13300 | .0511 | .0610 | 532 | 336.4 | 26/7 | 336.4 |
Cairo | 465.4 | 19 | 0.1565 | 0.783 | 434.0 | 15600 | .0433 | .0518 | 590 | 397.5 | 26/7 | 397.5 |
Darien | 559.5 | 19 | 0.1716 | 0.858 | 521.7 | 18800 | .0360 | .0431 | 663 | 477.0 | 26/7 | 477.0 |
Elgin | 652.4 | 19 | 0.1853 | 0.927 | 608.4 | 21900 | .0309 | .0371 | 729 | 556.5 | 26/7 | 556.5 |
Flint | 740.8 | 37 | 0.1415 | 0.990 | 690.8 | 24400 | .0272 | .0327 | 790 | 636.0 | 26/7 | 636.0 |
Greeley | 927.2 | 37 | 0.1583 | 1.108 | 864.6 | 30500 | .0217 | .0263 | 908 | 795.0 | 26/7 | 795.0 |
+Ampacity based on 75ºC conductor temperature, 25ºC ambient temperature, 2 ft/sec. wind in sun, emissivity 0.5, 52.5% conductivity. |
Frequently Asked Questions:
(1)Q: Is your company a factory or trading company?
A: We are factory with our own trading company. Our trade business expands home and abroad.
(2)Q: What is Minimum Order Quantity?
A: Generally, 1000 meters for building wire. For power cable, armored or unarmored, 500 meters.
(3)Q: Do you have any certificates?
A: We have CE and ISO 9001:2008. And type test report for ACSR, AAC, XLPE insulated power cable.
(4)Q: Which standards for your products?
A: We can produce wire and cable according to international standards: IEC, ASTM, BS, DIN, SANS, CSA or as customers’ requirement.
(5)Q: How about delivery time?
A: If we have stock, delivery would be very quick. For the newly-produced products, 15 to 25 days for production.
(6)Q: Payment terms:
A: Normally 30% paid as prepayment, balance paid before delivery. Or 100% L/C at sight.
(7)Q: What is your packing?
A: Generally, we have reels for wire, and wooden drums for small size of power cable, steel drums for biggers size cable. We try every means to ensure the good transportation.