450/750V, Low Voltage, Copper Conductor PVC/XLPE Insulated Control Cable.

450/750V, Low Voltage, Copper Conductor PVC/XLPE Insulated Control Cable.

450/750V, Low Voltage, Copper Conductor PVC/XLPE Insulated Control Cable.

KVV KVVP2 KVV22 KYJV KYJVP2 KYJV22 etc.

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC Cable

PVC

PVC

Round Wire

Red Copper Wire

ISO, CCC, CE

GDYG

Wooden Reel, Steel Reel

0.5mm2-630mm2

Guangdong Province, China

8544492100

Product Description

Type and Name

Type Name
KVV Copper conductor PVC insulated PVC sheathed control cable
KVVP2 Copper conductor PVC insulated PVC sheathed copper tape screened control cable
KVV22 Copper conductor PVC insulated PVC sheathed steel tape armored control cable
KVVP2-22 Copper conductor PVC insulated PVC sheathed copper tape screened, steel tape armored control cable
KVVR Copper conductor PVC insulated PVC sheathed control flexible cable
KVV32 Copper conductor PVC insulated PVC sheathed steel wire armored control cable
KVVP2-32 Copper conductor PVC insulated PVC sheathed copper tape screened steel wire armored control cable
KYJV Copper conductor XLPE insulated PVC sheathed control cable
KYJVP2 Copper conductor XLPE insulated PVC sheathed copper tape screened control cable
KYJV22 Copper conductor XLPE insulated PVC sheathed steel tape armored control cable
KYJVP2-22 Copper conductor XLPE insulated PVC sheathed copper tape screened steel tape armored control cable
KYJV32 Copper conductor XLPE insulated PVC sheathed steel wire armored control cable
KYJVP2-32 Copper conductor XLPE insulated PVC sheathed copper tape screened steel wire armored control cable

Construction Drawing

1.Conductor
2.Conductor screen (no light type)
3.Filler
4.Wrapping tape
5.Copper tape screen
6.Sheath
7.Extruded or lapped bedding
8.Double steel tape armour

Standards
It is manufactured in accordance with GB/T9330-2008, and the factory can also manufacture the cables in accordance with other standards such as IEC, BS, DIN, etc,it can also be produced according to special requirements put forward by clients.

Characteristics and Application
Plastic insulated control cable are used for connecting electrical equipments. It applies to controlling, monitoring and protective system with A.C. rated voltage U0/U up to and including 450/750V.

The main features of the flame retardant PVC control cable is hard to get fire or that the continuous burning of cables is very limited when it is on fire. It applies to the places with special demands of flame retardant property.

Fire-resistance cable can operate normally for some time when it is burning except that it can transmit electrical power under normal condition. It is used in the places necessary to resist fire.

Technical Parameter
KVV,ZC-KVV

Number of cores
x Nominal cross-section
mm2
Kind of
conductor
Reference
outside diameter
of cable
mm
Reference
weight of cable
kg/km
Max.D.C.
resistance
at 20ºC
Ω/km
Min.insulation
resistance
at 70ºC
MΩ·km
2 x 0.75 1 7.2 61 24.5 0.012
2 x 0.75 2 7.5 65 24.5 0.014
2 x 2.5 1 9.6 124 7.41 0.01
2 x 2.5 2 10.2 135 7.41 0.01
2 x 10 2 15.7 377 1.83 0.0065
5 x 0.75 1 8.7 101 24.5 0.012
5 x 0.75 2 9.1 108 24.5 0.014
5 x 2.5 1 12.7 247 7.41 0.01
5 x 2.5 2 13.4 267 7.41 0.01
5 x 10 2 20.4 769 1.83 0.0065
10 x 0.75 1 11.6 176 24.5 0.012
10 x 0.75 2 12.2 189 24.5 0.014
10 x 2.5 1 17.2 447 7.41 0.01
10 x 2.5 2 18.2 483 7.41 0.01
10 x 10 2 28.4 1452 1.83 0.0065
30 x 0.75 1 17.6 450 24.5 0.012
30 x 0.75 2 18.6 483 24.5 0.014
30 x 2.5 1 26 1167 7.41 0.01
30 x 2.5 2 27.6 1262 7.41 0.01
61 x 0.75 1 23.8 857 24.5 0.012
61 x 0.75 2 25.1 906 24.5 0.014
61 x 2.5 1 36 2320 7.41 0.01
61 x 2.5 2 38.3 2509 7.41 0.01

Our Company

Workshop

Certificates

Test

Customers

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.