450/750V 2.5mm2 PVC Insulated Electric Copper Housing Wire, 4mm2 Building Wire
Product Description
1.Range of Application
Building wire is fit for AC rated voltage 450/750V and below of domestic electrical appliances of smaller size motorized tools of instruments of various meters and motorized lighting installations.
2.Service Conditions
Working temperature:Not more than 105oC for RV-105 model.The other no more than 70oC.
3.Model and Name:see table1
Model |
Name |
RV |
Copper Core PVC Insulation Flexible Wire |
RVB |
Copper Core PVC Insulation Flat Flexible Wire |
RVS |
Copper Core PVC Insulation Twisted Flexible Wire |
RVV |
Copper Core PVC Insulation Sheath Round Flexible Wire |
RVVB |
Copper Core PVC Insulation Sheath Flat Flexible Wire |
RV-90 |
Copper Core Heat-resistak Losc PVC Flexible Wire |
4.Specification Size and Technical Data:see table 2
Nominal Section (mm2) |
Core Structure No./Dia.(mm) |
Max Dia.(mm) |
Reference Weight(kg/km) |
0.3 |
16/0.15 |
2.3 |
6.4 |
0.4 |
23/0.15 |
2.5 |
8.1 |
0.5 |
16/0.2 |
2.6 |
9.1 |
0.75 |
24/0.2 |
2.8 |
12.2 |
1.0 |
32/0.2 |
3.0 |
15.1 |
RV 450/750V
Nominal Section (mm2) |
Core Structure No./Dia.(mm) |
Max Dia.(mm) |
Reference Weight(kg/km) |
1.5 |
30/0.25 |
3.5 |
21.4 |
2.5 |
49/0.25 |
4.2 |
24.5 |
4 |
56/0.20 |
4.8 |
51.8 |
6 |
84/0.30 |
6.4 |
74.1 |
10 |
84/0.30 |
8.0 |
12.4 |
Single core, solid, stranded
Nominal section (mm2) |
Number/diameter of core ( mm ) |
Maximum outer Diameter ( mm2 ) |
Reference weight ( KG/KM ) |
Conductor resistance at 20ºC ( OMEGA/KM ) |
||
Conductor copper |
Conductor aluminum |
aluminum |
copper |
|||
1.5(A) |
1/1.38 |
3.3 |
20.3 |
|
|
12.1 |
1.5(B) |
7/0.52 |
3.5 |
21.6 |
|
|
12.1 |
2.5(A) |
1/1.78 |
3.9 |
31.6 |
17 |
11.80 |
7.41 |
2.5(B) |
7/0.68 |
4.2 |
34.8 |
|
|
7.41 |
4(A) |
1/2.25 |
4.4 |
47.1 |
22 |
7.39 |
4.61 |
4(B) |
7/0.85 |
4.8 |
50.3 |
|
|
4.61 |
6(A) |
1/2.76 |
4.9 |
65 |
29 |
4.91 |
3.08 |
6(B) |
7/1.04 |
5.4 |
71.2 |
|
|
3.08 |
10 |
7/1.35 |
7.0 |
119 |
62 |
3.08 |
1.83 |
16 |
7/1.70 |
8.0 |
179 |
78 |
1.91 |
1.15 |
25 |
7/2.14 |
10.0 |
281 |
118 |
1.20 |
0.727 |
35 |
7/2.52 |
11.5 |
381 |
156 |
0.868 |
0.524 |
50 |
19/1.78 |
13.0 |
521 |
215 |
0.641 |
0.387 |
70 |
19/2.14 |
15.0 |
734 |
282 |
0.443 |
0.268 |
95 |
19/2.52 |
17.5 |
962 |
385 |
0.320 |
0.193 |
120 |
37/2.03 |
19.0 |
1180 |
431 |
0.253 |
0.153 |
150 |
37/2.25 |
21.0 |
1470 |
539 |
0.206 |
0.124 |
185 |
37/2.52 |
23.5 |
1810 |
666 |
0.164 |
0.0991 |
240 |
61/2.52 |
26.5 |
2350 |
857 |
0.125 |
0.0754 |
Electric wire , single core , flexible
Nominal section ( mm2 ) |
Core structure No./Dia. ( mm ) |
Max dia. ( mm ) |
Reference weight ( kg/km ) |
0.4 |
23/0.15 |
2.5 |
8.1 |
0.5 |
16/0.2 |
2.6 |
9.1 |
0.75 |
24/0.2 |
2.8 |
12.2 |
1.0 |
32/0.2 |
3.0 |
15.1 |
1.5 |
30/0.25 |
3.5 |
21.4 |
2.5 |
49/0.25 |
4.2 |
24.5 |
4 |
56/0.30 |
4.8 |
51.8 |
6 |
84/0.30 |
6.4 |
74.1 |
10 |
84/0.40 |
8.0 |
12.4 |
PVC insulation PVC sheathed flexible electric cable
Nominal section ( mm2 ) |
NO./ Dia. ( mm ) |
Max dia. ( mm ) |
Reference weight ( kg/km ) |
2×0.75 |
2×24/0.20 |
7.6 |
50.0 |
2×1.0 |
2×32/0.20 |
7.8 |
57.8 |
2×1.5 |
2×30/0.25 |
8.8 |
74.7 |
2×2.5 |
2×49/0.25 |
11.0 |
120.0 |
3×0.75 |
3×24/0.20 |
8.0 |
63.1 |
3×1.0 |
3×32/0.20 |
8.4 |
74.0 |
3×1.5 |
3×30/0.25 |
9.6 |
102.0 |
3×2.5 |
3×49/0.25 |
11.5 |
162.0 |
4×0.75 |
4×24/0.20 |
8.6 |
78.5 |
4×1.0 |
4×32/0.20 |
9.2 |
97.2 |
4×1.5 |
4×30/0.25 |
11.0 |
133.0 |
5×0.75 |
5×24/0.20 |
9.4 |
96.9 |
5×1.0 |
4×32/0.20 |
11.0 |
115.0 |
- Next: General Rubber Sheath Power Cable
- Previous: General Rubber Sheath Pwer Cable
Contact us
Similar Or Related
-
Flexible Electric Cable V/J 1X70mm2 Copper PVC Insulated Wire for 90kV HV Substation
-
#4AWG XHHW-2 Annealed Copper Conductor XLPE Insulation Cable 600 Volts
-
300MCM XHHW-2 Annealed Copper Conductor XLPE Insulation Cable 600 Volts
-
6181Y 1X16mm2 PVC Insulated and Sheathed Wiring Cable BS 6004 300/500V
-
450/750V 2.5mm2 PVC Insulated Electric Copper Housing Wire, 4mm2 Building Wire