35kv 150mm2 185mm2 240mm2 Sac Spaced Aerial Cable
35kv 150mm2 185mm2 240mm2 Sac Spaced Aerial Cable
sac
Jinyuan
Sac
ISO, CCC
Bare Copper Wire
Round Wire
HDPE
XLPE
DC Cable
Low and Medium Voltage Cable
Construction, Overhead, Industrial, Power Station
Aluminum
Medium
Jinyuan
Wooden Drums
aluminum stranded
China
8544492100
Product Description
35kV 150mm2 185mm2 240mm2 SAC Spaced Aerial Cable
Construction
1. Conductor: Compact round stranded hard-drawn aluminum wires
2. Conductor screen: Semi conductive Cross-linked polyethylene (XLPE) compound
3. Insulation: Cross-linked polyethylene (XLPE)
4. Jacket: Black Cross-linked polythylene (XLPE)
Classification
25kV
Maximum conductor temperature: 90ºC
Maximum circuit voltage: 25,000V
AC test voltage: 38,000V
35kV
Maximum conductor temperature: 90ºC
Maximum circuit voltage: 35,000V
AC test voltage: 49,000V
Reference Standards
Construction: TIS 293-2541 Tables, ICEA S-66-524, TIS 2341-2555, IEC 60502.2
Rated voltage, No. of core and range of sectional area
Rate Voltage(kv):25kV 35kV
No. of core and sectional area(mm2) :
25kV: 35-240
35kV: 50-240
Construction
1. Conductor: Compact round stranded hard-drawn aluminum wires
2. Conductor screen: Semi conductive Cross-linked polyethylene (XLPE) compound
3. Insulation: Cross-linked polyethylene (XLPE)
4. Jacket: Black Cross-linked polythylene (XLPE)
Classification
25kV
Maximum conductor temperature: 90ºC
Maximum circuit voltage: 25,000V
AC test voltage: 38,000V
35kV
Maximum conductor temperature: 90ºC
Maximum circuit voltage: 35,000V
AC test voltage: 49,000V
Reference Standards
Construction: TIS 293-2541 Tables, ICEA S-66-524, TIS 2341-2555, IEC 60502.2
Rated voltage, No. of core and range of sectional area
Rate Voltage(kv):25kV 35kV
No. of core and sectional area(mm2) :
25kV: 35-240
35kV: 50-240
Conductor | Thickness of conductor Screen mm (Average) | Thickness of insulation mm (Nominal) |
Thickness of Jacket mm (Nominal) |
Overall Diameter Mm (Approx.) |
Conductor resistance at 20°C Ω/km (Max.) |
Insulation resistance at 15.6°C MΩ*km (Min.) |
Conductor Weight | Breaking strength N (Min) |
Current rating in free air at 40°C ambient A |
Cable weight Kg/km (Approx.) |
|||
Cross- sectional area mm2 (Nominal) |
Number of o wires (Min.) |
Diameter of i conductor mm (Approx.) |
|||||||||||
35 | 6 | 6.88 | 0.3 | 3.175 | 3.175 | 21.0 | 0.868 | 2580 | 94 | 5591 | 150 | 381 | |
50 | 6 | 7.92 | 0.3 | 3.175 | 3.175 | 22.0 | 0.641 | 2380 | 128 | 7313 | 181 | 438 | |
70 | 12 | 9.55 | 0.3 | 3.175 | 3.175 | 23.5 | 0.443 | 2126 | 185 | 10420 | 225 | 527 | |
95 | 15 | 11.27 | 0.3 | 3.175 | 3.175 | 25.5 | 0.320 | 1913 | 256 | 14098 | 275 | 636 | |
120 | 15 | 12.68 | 0.3 | 3.175 | 3.175 | 27.0 | 0.253 | 1759 | 324 | 18518 | 319 | 734 | |
150 | 15 | 14.05 | 0.3 | 3.175 | 3.175 | 28.0 | 0.206 | 1648 | 398 | 22457 | 362 | 838 | |
185 | 30 | 15.75 | 0.3 | 3.175 | 3.175 | 30.0 | 0.164 | 1521 | 500 | 58974 | 418 | 970 | |
240 | 30 | 18.23 | 0.3 | 3.175 | 3.175 | 32.5 | 0.125 | 1367 | 655 | 37506 | 497 |