2*10+1*10 Aluminum Cable ABC Overhead Insulated Aluminum Cable

2*10+1*10 Aluminum Cable ABC Overhead Insulated Aluminum Cable

2*10+1*10 Aluminum Cable ABC Overhead Insulated Aluminum Cable

ABC cable

Construction, Overhead

Low and Medium Voltage Cable

DC & AC

XLPE

No Jacket

Round Wire

Aluminum Conductor

ISO, CCC

ABC

Hongda

IEC

hongda

on The Drum or on The Pallent

10 16 25 35 50 70 95 120

Henan

8544492100

Product Description

We can produce ABC aluminum cable , overhead aluminium cable ,0.6/1kV ABC cable , aerial bundle cable ,ABC cable,pls refer to the following specification:

Aerial Bundled Cable, ABC Cable, Overhead cable, 0.6/1kV Aerial Bundle Overhead Aluminium XLPE Insulated ABC Cable.

Voltage

0.6/1kV

Cores

1, 2, 3, 4, 5, 6

Range of Nominal cross section

10 mm2 ~ 300 mm2

Application

A new type of aerial cable for power transmitting. It is extensively used in overhead power transmission line.

Standard

NF C 33-209, IEC, BS, SABS, ASTM

Constructions

Conductor:

Aluminium, Alloy Aluminium, ACSR

Insulation:

XLPE, PE

Size

2 x 16 mm2

3×25 mm2+54.6 mm2+16 mm2

2 x 25 mm2

3×35 mm2+54.6 mm2+16 mm2

2 x 35 mm2

3×50 mm2+54.6 mm2+16 mm2

2 x 50mm2

3×70 mm2+54.6 mm2+16 mm2

4 x 16 mm2

3×70 mm2+70 mm2+16 mm2

4 x 25 mm2

3×95 mm2+70 mm2+16 mm2

4 x 35 mm2

3×120 mm2+70 mm2+16 mm2

Max. Operating Temperature

90 ºC

Packing

Steel drum or as per requirement

Remark

The cable can be of flame retardant, fire resistance, environment friendly or other property

1. Application of Service Drop Cable:
Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.

2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.

3. Detaild Introduction of Service Drop Cable
3.1 Duplex Service Drop

Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Construction
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.

Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

ABC cable

16 mm 2 * 2C

( AL7/1.70+PE O.D.7.10) + AL7/1.70 or + AL6/1.70+G1/1.70

16 mm 2 * 4C

3*(AL7/1.70+PE O.D.7.10) + AL7/1.70 or + AL6/1.70+G1/1.70

25 mm 2 * 2C

( AL7/2.12+PE O.D.8.90) + AL7/2.12 or + AL6/2.12+G1/2.12

25 mm 2 * 4C

3*(AL7/2.12+PE O.D.8.90) + AL7/2.12 or + AL6/2.12+G1/2.12

35 mm 2 * 2C

( AL7/2.50+PE O.D.10.0) + AL7/2.50 or + AL6/2.50+G1/2.50

35 mm 2 * 4C

3*(AL7/2.50+PE O.D.10.0) + AL7/2.50 or + AL6/2.50+G1/2.50

50 mm 2 * 2C

( AL19/1.78+PE O.D.11.7) + AL19/1.78

50 mm 2 * 4C

3*(AL19/1.78+PE O.D.11.7) + AL19/1.78

70 mm 2 * 2C

( AL19/2.12+PE O.D.13.5) + AL19/2.12

70 mm 2 * 4C

3*(AL19/2.12+PE O.D.13.5) + AL19/2.12

95 mm 2 * 2C

( AL19/2.50+PE O.D.15.8) + AL19/2.50

95 mm 2 * 4C

3*(AL19/2.50+PE O.D.15.8) + AL19/2.50

Cross Section of Conductor
(mm2)

Min.Nos. of Wires for Conductor
(mm)

Insulation Thickness
(mm)

Average Max. O.D.per Single-core
(mm)

Max.Conductor Resistance at 20ºC
(Ω/km)

Min Insulated Resistance at Rated Working Temperature
(MΩ.km)

Cable Tensile Breaking Force

2×10

6

1.00

6.5×13.0

3.08

0.0067

0.67

1650

2×16

6

1.20

8.0×16.0

1.91

0.0065

0.65

2512

2×25

6

1.20

9.4×18.8

1.2

0.0054

0.54

3762

2×35

6

1.40

11.0×22.0

0.868

0.0054

0.54

5177

2×50

6

1.40

12.3×24.6

0.641

0.0046

0.46

7011

2×70

12

1.40

14.1×28.2

0.443

0.004

0.4

10354

2×95

15

1.60

16.5×33.0

0.32

0.0039

0.39

13727

2×120

15

1.60

18.1×36.2

0.252

0.0035

0.35

17339

2×150

15

1.80

20.2×40.4

0.206

0.0035

0.35

21033

2×185

30

2.00

22.5×45.0

0.164

0.0035

0.35

26732

2×240

30

2.20

25.6×51.2

0.125

0.0034

0.34

34679

4×10

6

1.00

6.5×26.0

3.08

0.0067

0.67

1650

4×16

6

1.20

8.0×32.0

1.91

0.0065

0.65

2512

4×25

6

1.20

9.4×37.6

1.2

0.0054

0.54

3762

4×35

6

1.40

11.0×44.0

0.868

0.0054

0.54

5177

4×50

6

1.40

12.3×49.2

0.641

0.0046

0.46

7011

4×70

12

1.40

14.1×56.4

0.443

0.004

0.4

10354

4×95

15

1.60

16.5×66.0

0.32

0.0039

0.39

13727

4×120

15

1.60

18.1×72.4

0.252

0.0035

0.35

17339

4×150

15

1.80

20.2×80.8

0.206

0.0035

0.35

21033

4×185

30

2.00

22.5×90.0

0.164

0.0035

0.35

26732

4×240

30

2.20

25.6×102.4

0.125

0.0034

0.34

34679

Tel: +86 371 55367868

Fax: +86 371 55367870

Mobile: +86 18339931106

Tags: , ,

Contact us

 

 

 

Success! Thanks for Your Request.
Error! Please Try Again.