19*1.5mm2 Copperconductor/Steel Tape Armored/Control Cable
Product Description
1.Application
The products are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.
2.Standard
The products can be produced according to the standard GB9330-1988,and the factory can also manufacture the cables in accordance with other standards.
3.Service Conditions
(1).The long-time working temperature of conductor of PVC insulated cable is 70oC
The long-time working temperature of conductor of XLPE insulated cable is 90oC
(2).The temperature for laying the cables can not be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D
4.Type (see following table)
Type | Name | Section Area (mm2) | No.of Core | Application Site |
KVV | CopperConductor,PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP | Copper Conductor, PVC Insulated and Sheathed,Braiding Shielded Control Cable |
0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP2 | Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable |
0.75 1.0 1.5 2.5 | 4-10 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 7-61 | |||
10 | 4-10 | |||
KVV22 | Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable |
0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches, Be able to withstand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-14 | |||
KVVR | Copper Conductor, PVC Insulated and Sheathed,Flexible Control Cable |
0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KVVRP | Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable |
0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movability are required |
1.5 2.5 | 4-48 | |||
KYJV | CopperConductor, XLPE Insulated and PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJVP | Copper Conductor, XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJV22 | CopperConductor,XLPE Insulated,Steel-tape Armoured, PVCSheathed Control Cable |
0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVP2 | CopperConductor,XLPE Insulated, Copper tape Screened,PVCSheathed Control Cable |
0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVR | CopperConductor,XLPE Insulated, PVCSheathed Flexible Control Cable |
0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KYJVRP | CopperConductor,XLPE Insulated,Braiding Shielded, PVC Sheathed Flexible Control Cable |
0.5 0.75 1.0 | 4-61 | |
1.5 2.5 | 4-48 | Installation indoors where flexibility shielding and movability are required |