11kv Copper Cable XLPE Cable 3X120mm

11kv Copper Cable XLPE Cable 3X120mm

11kv Copper Cable XLPE Cable 3X120mm

11kv xlpe cable 3x120mm

Construction, Underground, Industrial, Power Station

Low and Medium Voltage Cable

DC Cable

XLPE

PVC

Round Wire

Bare Copper Wire

ISO, CCC, CE

YJV

Jytop

95mm 120mm 150mm

Black,Red,Yellow,Blue,Brown,Green

6.35/11kv

Manufacturer

CE, ISO 9001

11kv Copper Cable

11kv XLPE Cable

11kv Power Cable 3X120mm

3X120mm

JYTOP

Packed in Reels

IEC Standard 60502-2

Zhengzhou, China

8544601200

Product Description

1. CE, ISO 9001 Certificaes
2. More than 23 years experiences
3. Professional Manufacturer with Factory located in Henan Province.
4. Quick response and fast delivery.
5. Serve everyone with heart and soul.

6.35/11kV CU/XLPE/PVC(or PE) Power Cable

1. Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic
polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.

Chinese Type Description Core qty Conductors range
YJV Copper conductor, XLPE insulation, PVC outer sheath Power Cable 1 or 3 25~800mm2
YJY Copper conductor, XLPE insulation, PE outer sheath Power Cable 1 or 3 25~800mm2
ZA-YJV ZB-YJV ZC-YJV Copper conductor, XLPE insulation flame-retardant Power Cable 1 or 3 25~800mm2
WDZA-YJY WDZB-YJY WDZC-YJY Copper conductor, XLPE insulation Low Smoke Halogen Free or Zero
Halogen (LSHF or LSZH) flame-retardant Power Cable
1 or 3 25~800mm2

2. Operating Characteristics
Rated voltage U0/U(Um): 6.35/11(12)kV

U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed; U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.

Max. permissible continuous operating temperature of conductor: 90 °C

Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C The ambient temperature under installation should not be lower than: 0 °C
The bending radius of cable is recommended as following:

For single core cable: not less than 20 times of the diameter of cable

For three core cable: not less than 15 times of the diameter of cable

3. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.

4. Manufacturing Standards
IEC 60502-2 and Chinese National Standard GB/T 12706-2008

We can produce above cables according to popular international standards such as ASTM,BS,DIN,NF &AS/NZ also.

5. Main technical data

5.1 Main technical data of 6.35/11KV, Single core, Copper conductor, XLPE insulated, and PVC or PE sheath cable

CABLE CONSTRUCTION: 6.35/11KV CU/XLPE/PVC or PE

Size Nominal
thickness of
XLPE
insulation(mm)
Approx.
thickness of copper tape
screen (mm)
Nominal
thickness of
PVC or
PE(mm)
Approx. overall
diameter of finished
cable(mm)
Max. conductor D.C resistance @ 200C (Ω/km)
1x25mm2 3.4 0.12 1.8 20.3 0.727
1x35mm2 3.4 0.12 1.8 21.3 0.524
1x50mm2 3.4 0.12 1.8 22.4 0.387
1x70mm2 3.4 0.12 1.8 24.1 0.268
1x95mm2 3.4 0.12 1.8 25.7 0.193
1x120mm2 3.4 0.12 1.8 27.1 0.153
1x150mm2 3.4 0.12 1.8 28.7 0.124
1x185mm2 3.4 0.12 1.9 30.5 0.0991
1x240mm2 3.4 0.12 2.0 33.1 0.0754
1x300mm2 3.4 0.12 2.0 35.1 0.0601
1x400mm2 3.4 0.12 2.1 38.5 0.0470
1x500mm2 3.4 0.12 2.2 42.2 0.0366
1x630mm2 3.4 0.12 2.3 46.3 0.0283
1x800mm2 3.4 0.12 2.5 50.4 0.0221

5.2 Main technical data of 6.35/11KV Single core, Copper conductor, XLPE insulated, copper wire screened and

PVC or PE sheath cable

CABLE CONSTRUCTION: 6.35/11KV CU/XLPE/CWS/PVC or PE

Size Nominal
thickness of
XLPE
insulation(mm)
Approx.
thickness of copper tape
screen (mm)
Nominal diameter
of copper wire(mm)
Nominal
thickness of
PVC or
PE(mm)
Approx. overall
diameter of finished
cable(mm)
Max.
conductor D.C
resistance @
200C (Ω/km)
1x25mm2 3.4 0.12 0.9 1.8 21.9 0.727
1x35mm2 3.4 0.12 0.9 1.8 22.9 0.524
1x50mm2 3.4 0.12 0.9 1.8 24.0 0.387
1x70mm2 3.4 0.12 0.9 1.8 25.7 0.268
1x95mm2 3.4 0.12 0.9 1.8 27.3 0.193
1x120mm2 3.4 0.12 0.9 1.8 28.7 0.153
1x150mm2 3.4 0.12 0.9 1.8 30.3 0.124
1x185mm2 3.4 0.12 0.9 1.9 32.1 0.0991
1x240mm2 3.4 0.12 0.9 2.0 34.7 0.0754
1x300mm2 3.4 0.12 0.9 2.1 36.9 0.0601
1x400mm2 3.4 0.12 0.9 2.2 40.3 0.0470
1x500mm2 3.4 0.12 0.9 2.3 44.2 0.0366
1x630mm2 3.4 0.12 0.9 2.4 48.0 0.0283
1x800mm2 3.4 0.12 0.9 2.5 52.0 0.0221

5.3 Main technical data of 6.35/11KV, three cores, Copper conductor, XLPE insulated, and PVC or PE sheath cable

CABLE CONSTRUCTION: 6.35/11KV CU/XLPE/PVC or PE

Size Nominal thickness of
XLPE
insulation(mm)
Approx. thickness of
copper tape screen (mm)
Nominal thickness of
PVC or
PE(mm)
Approx. overall diameter of
finished cable(mm)
Max. conductor D.C resistance @ 200C (Ω/km)
3x25mm2 3.4 0.10 2.2 40.9 0.727
3x35mm2 3.4 0.10 2.3 43.3 0.524
3x50mm2 3.4 010 2.4 45.9 0.387
3x70mm2 3.4 0.10 2.5 49.8 0.268
3x95mm2 3.4 0.10 2.6 53.6 0.193
3x120mm2 3.4 0.10 2.7 56.8 0.153
3x150mm2 3.4 0.10 2.8 60.6 0.124
3x185mm2 3.4 0.10 2.9 64.3 0.0991
3x240mm2 3.4 0.10 3.1 69.9 0.0754
3x300mm2 3.4 0.10 3.3 74.6 0.0601
3x400mm2 3.4 0.10 3.5 82.2 0.0470