1000V 16mm2 Solid Aluminum Conductor CNE / SNE Concentric Neutral Cable

Concentric Cable
Available in different form, this Concentric Cable readily replaces the low voltage copper cables to avoid any energy robbery, thus also known as anti-robbery cable. This is constructed n such a way that there is no use of claws and is surrounded by phase like a wire that does not permit any contact with central phase. Therefore, this is used by distribution network operators that links electrical network to any home and business. The processing is done at our manufacturing unit by making use of factory tested components that are sourced from trustworthy vendors along with modern machines and cutting edge technology. Moreover, the available range is tested on different quality parameters under the strict guidance of our professionals to make sure the reliable performance.

Features
Approximate weight
Even cross section
Nominal outer diameter
Corrosion free
Effective performance

Aerial Service Connection Cable (CNE)

Description:
Stranded hard drawn copper phase conductor, XLPE insulated, Polyethylene insulated with bare/neutral earth conductors. Polyethylene sheathed house service cable. Nylon ripcord laid under sheath.

Application:
AerialCNE Cable is used for house connections. This cable can only be used for single phase supply. Cable is made to be suspended in the air. Aerial SNE Cable is also suitable for underground general use.

Specifications:
CONCENTRIC NEUTRAL & EARTH
SANS 1507-6

Available Sheath Colours:
Black

CABLE SIZE
mm²
10 16
Phase Conductor Resistance (0hm/Km) DC @20ºC 1.89 1.19
Phase Conductor Impedance (0hm/km) 2.34 1.47
Phase Conductor Strand size (mm) & No. 1.35 x 7 1.74 x 7
Phase Conductor Insulation Thickness (mm) 0.7 0.7
Phase conductor 0D (mm) 5.45 6.41
Neutral Size (mm²) 10 16
Neutral conductor Strand size (mm) & No. 1.33 x 7 1.67 x 7
Earth size (mm²) 7.5 11
Earth Conductor Strand Size (mm) & No. 1.78 x 3 2.2 x 3
Communication Cores – Solid – OD (mm) & No 0.8 x 2 0.8 x 2
Current Rating (A) 67 89
(In air 30ºC ambient -max Conductor Temperature 90ºC)
Nominal Sheath Thickness (mm) 1.4 1.6
Approximate Cable OD (mm) 12 14.0
Approximate Cable Mass (Kg/Km) 319 488.0

Aerial Service Connection Cable (SNE)

Description:
Stranded hard drawn copper phase conductor, SLPE insulated, Polyethylene insulated neutral with bare earth conductors. Polyethylene sheathed cable. Nylon ripcord laid under sheath.

Application:
Aerial SNE Cable is used for house connections. This cable can only be used for single phase supply. Cable is made to be suspended in the air. Aerial SNE Cable is also suitable for underground general use. Split concentric cable suitable for power distribution as an underground or overhead cable.

Specifications:
SPLIT NEUTRAL AND EARTH
SANS 1507-6
CONDUCTOR TYPE: Insulated neutral and bare earth conductors

Available Sheath Colours:
Black

CABLE SIZE
mm²
10 16
Phase Conductor Resistance (0hm/Km) DC @20ºC 1.89 1.2
Phase Conductor Impedance (0hm/km) 2.34 1.5
Phase Conductor Strand size (mm) & No. 1.35 x 7 1.74 x 7
Phase Conductor Insulation Thickness (mm) 0.7 0.7
Phase conductor 0D (mm) 5.45 6.4
Neutral Size (mm²) 10 16.0
Neutral conductor Strand size (mm) & No. 1.33 x 7 1.67 x 7
Earth size (mm²) 7.5 11.0
Earth Conductor Strand Size (mm) & No. 1.78 x 3 2.2 x 3
Communication Cores – Solid – OD (mm) & No 0.8 x 2 0.8 x 2
Current Rating (A) 67 89.0
(In air 30ºC ambient -max Conductor Temperature 90ºC)
Nominal Sheath Thickness (mm) 1.4 1.6
Approximate Cable OD (mm) 12 14.0
Approximate Cable Mass (Kg/Km) 319 488.0

All calculations must be verified by a qualified electrician under no circumstances can continental cables be held responsible for an accident resulting from the use of this application. These calculations to be used as a guide line only.