0.6/1kv Aluminium Conductor Quadruplex Service Drop/ABC Cable

0.6/1kv Aluminium Conductor Quadruplex Service Drop/ABC Cable

0.6/1kv Aluminium Conductor Quadruplex Service Drop/ABC Cable

3*4AWG+1*4AWG, 3*336.4+1*336.4

Insulated

Stranded

Overhead

Aluminum

PVC

XLPE

Round Wire

Cold-Resistant

ISO9001, CE

SABS

Jiapu

JP

Wooden Drums or Wooden-Steel Drums

3*4AWG+1*4AWG, 3*336.4+1*336.4

China

8544492100

Product Description

SpecificationsTo supply power from the utility lines to the consumers weather head.For service at 600 volts or less(phase to phase).
Aerial Bundled Cable is a new type aerial bundled cable used for transmitting electric power overhead.

Standards

1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

Applications

To supply power from the utility lines to the consumers weather head.For service at 600 volts or less(phase to phase) at a conductor temperature of 75oC maximum for polyethylene insulation or 90ºC maximum for cross linked insulation.

Construction

1.stranded aluminum conductor
2.PE or XLPE insulation
3.ACSR, AAAC,Galvanized steel wire Messenger wire
3 power cores consisting of standard aluminum conductors, insulated with XLPE insulation
+ One sheath lighting aluminum conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor

Technical Data:
Maximum operating temperature 90 degree
Maximum short-circuit temperature 250 degree.Service drop( ABC cables) are especially used at areas where the cost of underground networks is expensive and also for electrification of rural areas like village.

Classification

1. Duplex Service Drop

Primary used for 120 volt overhead service application such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase to phase or less and at conductor temperature not to exceed 75degee for polyethylene insulated conductor or 90 degree for cross linked polyethylene (XLPE)insulated conductors.

2.Triplex Service Drop

Used to supply power, usually from a pole-mounted transformer to the user’s service head where the connections to the service entrance cable is made. To be used at voltage of 600 volts phase to phase or less and at conductor temperature not to exceed 75degee for polyethylene insulated conductor or 90 degree for cross linked polyethylene (XLPE)insulated conductors.

3. Quadrupled Service Drop

Used to supply 3 phase power, usually from a pole-mounted transformer to the user’s service head where the connections to the service entrance cable is made. To be used at voltage of 600 volts phase to phase or less and at conductor temperature not to exceed 75degee for polyethylene insulated conductor or 90 degree for cross linked polyethylene (XLPE)insulated conductors.

Package:In coils, wooden drums, steel drums or steel-wooden drums.