XLPE Insulation Al/R ABC Cable 2X16mm2 4X16mm2 Aerial Power Cable
More product about ABC CableProduct Description
Application
The power cables with cross-linked polyethylene (XLPE) insulation for overhead lines are designed for electrical installations with alternating power networks with nominal voltage Uo/U 0.6/1 kV or in direct power networks with maximum voltage according to land 0.9 кV. The cables with supporting (bearing) zero conductors are used for building networks in city and urban areas and the self-supporting type cables are for building distribution networks in these areas.
The cables with supporting (bearing) zero conductors are used for building networks in city and urban areas and the self-supporting type cables are for building distribution networks in these areas.
Cables for overhead installations may be used in different types of installations: on free hanging facades; between posts; on fixed facades; trees and poles. Interception of forest areas without the need of clearance and maintenance of openings is allowed.
-Cables with supporting zero conductor, the whole bundle is suspended and carried by the supporting conductor, which is made of aluminum compound.
– Self-supporting construction, suspension and carrying of the whole bundle is done by the phase insulated conductors. Bundles can include one or two additional conductors for public lighting and control pair.
STANDARDS
IEC60502, NFC 33 209, AS/NZS 3560.1.
Cable construction | |
Construction | According to NF C 33-209 |
Conductor phase(main) M |
Al stranded compacted or Non-compacted according to NF C 33-209 |
– neutral (supporting) N | AL stranded according to NF C 33-209 |
-additional for lighting R | Al stranded compacted or non-compacted according to NF C 33-209 |
Insulation | XLPE with min. 2% carbon black content Constructions twisted into a bundle include: – phase (main) insulated cores(M) – neutral supporting insulated core ( N ) – one, two, or three additional reduced insulated cores for lighting ( R ) |
Color | black |
Marking: | raised with paint: |
– phase ( M ) – with numbers 1;2;3 | |
– supporting 0 core( N ) | |
HENAN HONGDA CABLE NF C 33-209 | |
additional cores for lighting ( R ) – EP1 and EP2 |
Technical data | |
Conductor resistance at 20°C | According to NF C 33-209 |
Operating temperature | 90ºC – continuous operation |
Overload temperature | 130ºC – /100h/per year max./ |
Short circuit temperature | 250ºC /5 s max./ |
Nominal voltage AC DC |
Uo/U 0.6/1 kV 0.9 kV |
Highest system voltage AC, not more than |
1.2 kV |
Test voltage: AC -15 min DC – 15 min |
4 kV 10 kV between cores – 3.5 kV between core and armor – 3.5 kV |
Bending radius, min. Temperature of laying | – 18x D cable no less than – 10ºC – recommended 15°C |
Resistance at 20°C: | 16 -1.91 Ω/km 70-0.443 Ω/km 25 -1.20 Ω/km 95-0.320 Ω/km |
|
35 – 0.868 Ω/km 120-0.253 Ω/km 50 – 0.641 Ω/km 150-0.206 Ω/km 54.6Alm-0.63 Ω/km; 70Alm -.5 Ω/km |
Supported neutral breaking strength min |
95Alm – 0.343 Ω/km 54.6 – 16 kN 70 – 20.50 kN 95 – 27.50 kN |
Al Aerial Bundled cables (ABC)
Construction data Al/R 0.6/1 kV | ||||||
Number of conductors and nominal cross section |
Thickness of insulation M/N/R | Diameter of bundle approx. |
Allowed current in power supply networks | Allowed current in distribution networks | Al/R | |
Mass of Al core approx. | Cable weight approx. | |||||
LlE | mm | mm | A | kg/km | kg/km | |
walls/air/facades | ||||||
2×16 | 1.2 | 15 | – | 72 / 93 / 83 | 91 | 125 |
2×25 | 1.4 | 18 | – | 95 / 122 / 111 | 142 | 165 |
4×16 | 1.2 | 18 | – | 63 / 83 / 75 | 183 | 260 |
4×25 | 1.4 | 22 | – | 83 / 111 / 99 | 285 | 395 |
3×25+54.6Alm | 1.4/1.6 | 30 | 112 | – | 369 | 505 |
3×25+54.6Alm+Kx16 | 1.4/1.6/1.2 | 30 | 112 / 83 | – | 460 | 635 |
3×35+54.6Alm | 1.6/1.6 | 33 | 138 | – | 455 | 615 |
3×35+54.6Alm+Kx16 | 1.6/1.6/1.4 | 33 | 138 / 83 | – | 546 | 745 |
3×50+54.6Alm | 1.6/1.6 | 36 | 168 | – | 583 | 725 |
3×50+54.6Alm+Kx16 | 1.6/1.6/1.2 | 36 | 168 / 93 | – | 674 | 860 |
3×50+54.6Alm+Kx25 | 1.6/1.6/1.4 | 36 | 168 / 111 | – | 725 | 925 |
3×70+54.6Alm | 1.8/1.6 | 37 | 213 | – | 754 | 950 |
3×70+54.6Alm+Kx16 | 1.8/1.6/1.2 | 40 | 213 / 83 | – | 845 | 1080 |
3×70+54.6Alm+Kx25 | 1.8/1.6/1.4 | 40 | 213 / 111 | – | 896 | 1150 |
3×70+70Alm | 1.8/1.5 | 41 | 213 | – | 798 | 984 |
3×70+70Alm+Kx16 | 1.8/1.5/1.2 | 41 | 213 / 83 | – | 889 | 1115 |
3×70+70Alm+Kx25 | 1.8/1.5/1.4 | 41 | 213 / 111 | – | 940 | 1185 |
3×95+54.6Alm | 1.8/1.6/ | 44 | 258 | – | 967 | 1195 |
3×95+54.6Alm+Kx16 | 1.8/1.6/1.2 | 44 | 258 / 83 | – | 1059 | 1325 |
3×95+54.6Alm+Kx25 | 1.8/1.6/1.4 | 44 | 258 / 111 | – | 1110 | 1355 |
3×95+70Alm | 1.8/1.5 | 44 | 258 | – | 1011 | 1355 |
3×95+70Alm+Kx16 | 1.8/1.5/1.2 | 44 | 258 / 83 | – | 1102 | 1615 |
3×95+70Alm+Kx25 | 1.8/1.5/1.4 | 44 | 258 / 111 | – | 1154 | 1485 |
3×120+70Alm | 1.8/1.5 | 46 | 300 | – | 1225 | 1445 |
3×120+70Alm+KxT6 | 1.8/1.5/1.2 | 46 | 300 / 83 | – | 4828 | 1575 |
3×120+70Alm+Kx25 | 1.8/1.5/1.4 | 46 | 300 /111 | – | 1368 | 1610 |
3×120+95Alm | 1.8/1.6 | 47 | 300 | – | 1296 | 1535 |
SxT20+95Alm+KxTb | 1.8/1.6/1.2 | 47 | 300 / 83 | – | 1387 | 1660 |
3×120+95Alm+Kx25 | 1.8/1.6/1.4 | 47 | 300 / 111 | – | 1439 | 1735 |
3×150+70Alm | 1.7/1.5/ | 48 | 344 | – | 1482 | 1670 |
3×150+70Alm+Kx16 | 1.7/1.5/1.2 | 48 | 344 / 83 | – | 1573 | 1795 |
3×150+70Alm+Kx25 | 1.7/1.5/1.4 | 48 | 344 / 111 | – | 1624 | 1870 |
This data was prepared for informational purposes only and does not contain any representations, legally binding declarations or guarantees. Contractual obligations shall only come into effect after a written contract, detailing the terms and conditions, has been signed. A liability of Hongda cables for the correctness of the information contained herein is excluded. The data shall not be handed out to third parties or disclosed in public documents. Any intellectual property rights remain with Hongda cables and are reserved.
More question and inquiry, please contact with Vivian Yuan, phone number: +86-18339931106.
Similar Or Related