XLPE insulated power cable for voltage up to 46KV

1. Introduction

Cross-linked polyethylene insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical corrosion, heat aging and environmental stress. Its structure is simple. The long term operating temperature is 90ºC.It is convenient to use and can be laid with no restriction of different level.
Our enterprise can produce both flame retardant and non-flame retardant series of XLPE power cable.
Our XLPE Power cable can be produced according to our works’ specifications, which are equivalent to IEC, DIN, BS and ASTM, and its some indexes are superior to standards stated above.
The flame-retardant cable covers all kinds of low-smoke low-halogen , low-smoke halogen free and three classes of A,B,C.
We can design and manufacture special XLPE cable according to the other standards required by the customers, such as Heavy section cut apart conductors , water-resistance , defend termites , defend mouse , and so on.

 

2.  Scope of voltage grade and core number and cross-section

a) IEC/BS/DIN Standard

Rated Voltage (kV) 3.6/6 6/6 6/10 8.7/10 8.7/15 12/15 12/20 18/20 18/30 21/35 26/35
Core Number 1Core       3Core
Cross- section
mm2
1C 25~800 35~800
3C 25~400 35~400

b) ASTM standard

Rated Voltage (V) 5001-8000 8001-15000 15001-25000 25001-28000 28001-35000 35000-46000
Core Number 1Core 3Core
Cross-section
AWG or kcmil
1C 6AWG~1600kcmil 2AWG~1600kcmil 1AWG~1600kcmil 2AWG~1600kcmil 1/0AWG~1600kcmil
3C 6AWG~1600kcmil 2AWG~1600kcmil 1AWG~1600kcmil 2AWG~1600kcmil 4/0AWG~1600kcmil

3.  Service conditions and operation parameters of Cable
a) Max. conductor operating temperature: 90ºC
b) Short Circuit Temperature:250ºC
c) Ambient temperature: 30ºC
d) Soil temperature: 20ºC
e) Depth of laying in direct : 0.8m
f) Thermal Resistance of soil : 150ºC.cm/W
g) Thermal Resistance of ducts : 120ºC.cm/W

 