Single Core Medium Voltage Cable

Single Core Medium Voltage Cable
Insulated
Stranded
Power Station
Copper or Aluminum
PVC or PE
XLPE
Round Wire
Power Station
ISO9001, CE
Yifang
XLPE
Yifang cable
Drum or According to U Request
Iec Bs ASTM DIN CSA as and So on
Zhengzhou, China

Product Description

The medium voltage cable:

1. The products are mainly complying with iec 60502 standard, also can be produced according to OEM requirements and other standards, such as bs standard, DIN standard, ASTM standard, etc.

2. Voltage grade

2.1 low voltage cable

Low voltage (0.6/1 kv) single core or multi-core/ copper or aluminium conductor/ PVC inusulation/ steel tape armored or galvanized steel wire armored or unarmored/ PVC outer sheath power cable.

2.2 medium voltage cable

Voltage grade is up to 35kv, cross-section area can be up to 1000 sqmm (copper or aluminiun conductor). Conductor long-time operating temperature is 90 degrees. In short circuit, conductor highest temperature should be not more than 250 degrees.

1kv-35 kv multi-cores/ copper or aluminium conductor/ XLPE insulation / copper tape or copper wire screen / galvanized steel wire armored / PVC or PE sheath / power cable,

2.3 high voltage cable

High voltage (35kv~220kv) copper or aluminium conductor/ XLPE insulation/ metal sheath (lead or corrugated aluminium)/ HDPE or PVC outer sheath power cable.

Laying conditions: For lyaing under ground with large different altitude, be able to bear external machanical force and moderate pulling force.

Laying conditions: For lyaing under ground with large different altitude, be able to bear external machanical force and moderate pulling force.

3. Cable’s characteristic:

3.1 long time operating temperature for cable conductor is 90 degrees.

3.2 the highest temperature of the conductor in short circuit (no longer than 5 seconds) in not more than 250 degrees, if a joint is in the cable, the temperature of the tinning welding joint is not more than 120 degrees, compressing joint not more than 150 degrees and electro-welding joint not more than 250 degrees.

3.3 no drop in limited provided there is full mechanical tention when cable is laid. It si forbidden to lay cable in iron-pipe or to fix cable by circling around the cable with iron materials.

3.4 being laid, the minimum temperature of the cable shall not be lower than zero degree. In the case of lower temperature, heating measures shall be taken.