Service Drop ABC Cable Hot Selling Insulated Aerial Cable

Service Drop ABC Cable Hot Selling Insulated Aerial Cable
ABC Triplex 1/0AWG Neritina
Overhead Power Distribution
Aluminum
XLPE
ISO9001,ISO14001,SGS
Non-Jacket
2+1
up to 600V
30 Years Experience
Bare ACSR
ASTM Icea S-76-474
Southeast Asia,Middle East,Africa,America,etc
Weather Resistance,Ultra Violet Resistance
JINSHUI
Wooden Drums.
Henan, China (Mainland)

Product Description

Service drop ABC cable Triplex 1/0awg Neritina ICEA S-76-474

1.Application

ABC cable is primarily used on lighting, outdoor lighting, and temporary service for construction.To be used at voltages of 600V phase-to-phase or less,and the conductor temperatures no exceeds 75 degrees for polyethylene(PE)

insulated conductors or 90 degrees for corsslinked polyethylene(XLPE) insulated conductors.

2.ABC cable meets of exceeds the following specifications

2.1. Aluminum cable,1350-H19 for electrical purposes.

2.2.Aluminum conductors,concentric lay stranded.

2.3.Aluminum conductor,concentric lay stranded,coated steel reinforced(ACSR).

2.4.Concentric lay stranded,6201-T81 conductors.

2.5.Compressed round stranded aluminum conductors using single input conductor.

3.ABC cable based on ASTM ANSI/ICEA S-76-474

Phase core: AAC,XLPE cover.

Neutral core: AAC/ACSR/AAAC.

Sizes: 8AWG,6AWG,4AWG,2AWG,1/0AWG,2/0AWG,3/0AWG,4/0AWG,etc.

Specification:Duplex service drop,Triplex service drop,Quadruplex service drop.

4.ABC cable based on IEC standard

4.1.No.cores:1+1,2+1,3+1.

4.2.Nominal sizes of each core

Phase core:10mm2,16mm2,25mm2,35mm2,50mm2,70mm2,95mm2

Neutral core:10mm2,16mm2,25mm2,35mm2,50mm2,70mm2.

4.3.Material of core conductor

Phase core: AAC(all aluminum conductors)

Neutral core: AAAC(all aluminum alloy conductors).

4.4.Material of insulation:XLPE/PE.

5. ABC cable based on NFC33-209 standard

Description Insulated phase conductors Average
Insulation
Thickness
Type Nominal
Cross-section area
wire No.
in the
conductor
Max. resistance
at 20°C
Average dia. of
conductors
Rated
strength
mm2 No. Ohm/km Mini.
mm
Max.
mm
Mini
kN
mm
Phase,Neutral,
and
Public Lighting
16 7 1.91 4.6 5.1 1.9 1.2
25 7 1.2 5.8 6.3 3 1.4
35 7 0.868 6.8 7.3 1.6
50 7 0.641 7.9 8.4 1.6
70 12 0.443 9.7 10.2 1.8
95 19 0.32 11 12 1.8
120 19 0.253 12 13.1 1.8
150 19 0.206 13.9 15 1.7
Porter 54.6 7 0.63 9.2 9.6 16.6 1.6
70 7 0.5 10 10.2 20.5 1.5
95 19 0.343 12.2 12.9 27.5 1.6

Large scale,Strong capacity;

Reliable quality&Best prices!

Welcome to enquiry at any time!