PVC Insulated and Sheathed Braid Shield Control Cable
More product about Braiding Shielded Copper Control CablePVC Insulated and Sheathed Braid Shield Control Cable
vv
Insulated
Stranded
Used as Power and Connecting Cables
Copper
PVC
ISO9001, CE
450/750V
JINSHUI CABLE
Wooden Drum/Roll
Any standard
China
85444921
Product Description
1.Application
Used as power and connecting cables in mechanical engineering for tooling machinery, control unit, production lines, transportation equipment, conveyor and assembly lines as well as in plant construction under the circumstance that the rated voltage is up to 450/750V AC.
Used as power and connecting cables in mechanical engineering for tooling machinery, control unit, production lines, transportation equipment, conveyor and assembly lines as well as in plant construction under the circumstance that the rated voltage is up to 450/750V AC.
2.Character and Relevant Parameters
1. Long-term service temperature of the cable conductor: 70 0C
2. Rated voltage: 450/750V
3. Cable lying temperature ≥0 0C
4. Cores: 2, 3, 4, 5, 6,7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52, 61
5. Minimun bending radius:
Non armored ≥ out diameter of cable 6 times
Armored layer or copper tape shielded ≥ outer diameter of cable 12 times
Shielded layer soft cable ≥ outer diameter of cable 6 times
3.Type (see following table)
PVC insulated control cable
XLPE insulated control cable
4.Type (see following table)
Type | Name | Section Area (mm2) | No.of Core | Application Site |
KVV | CopperConductor,PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP | Copper Conductor, PVC Insulated and Sheathed,Braiding Shielded Control Cable |
0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP2 | Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable |
0.75 1.0 1.5 2.5 | 4-10 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 7-61 | |||
10 | 4-10 | |||
KVV22 | Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable |
0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches, Be able to withstand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-14 | |||
KVVR | Copper Conductor, PVC Insulated and Sheathed,Flexible Control Cable |
0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KVVRP | Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable |
0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movability are required |
1.5 2.5 | 4-48 | |||
KYJV | CopperConductor, XLPE Insulated and PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJVP | Copper Conductor, XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJV22 | CopperConductor,XLPE Insulated,Steel-tape Armoured, PVCSheathed Control Cable |
0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVP2 | CopperConductor,XLPE Insulated, Copper tape Screened,PVCSheathed Control Cable |
0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVR | CopperConductor,XLPE Insulated, PVCSheathed Flexible Control Cable |
0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KYJVRP | CopperConductor,XLPE Insulated,Braiding Shielded, PVC Sheathed Flexible Control Cable |
0.5 0.75 1.0 | 4-61 | |
1.5 2.5 | 4-48 | Installation indoors where flexibility shielding and movability are required |
Similar Or Related