PVC Insulated and Sheath Flexible Control Cable

PVC Insulated and Sheath Flexible Control Cable
KVV KVV32
Insulated
Stranded
Used as Connecting Cable
Copper
PVC
PVC
Round Wire
Flame Retardant
ISO9001, CE, UL, CCC
CHINT
450/750V
Jinshui
100 Meters Per Roll or Wooden Drum
China

Product Description

1. Application
Used as power and connecting cables in mechanical engineering for tooling machinery, control unit, production lines, transportation equipment, conveyor and assembly lines as well as in plant construction under the circumstance that the rated voltage is up to 450/750V AC.

2. Standard
National Standard GB/T9330-2008, produced according to IEC\DIN\BS

3. Rated Voltage: 450/750V

4. Construction:
1, copper conductor
2, PVC/PE/XLPE insulated
3, PVC sheathed
4. Copper wire braid/Aluminum-plastic shield/copper tape wrapped/unarmored
Steel tape armored

5. Type (see following table)

Type Name Section Area (mm2) No.of Core Application Site
KVV CopperConductor,PVC Insulated and Sheathed Control Cable 0.75 1.0 1.5 2.5 2-16 Permanent installation indoors,in cable ditches or pipes
4 6 2-14
10 2-10
KVVP Copper Conductor,
PVC Insulated and Sheathed,
Braiding Shielded Control Cable
0.75 1.0 1.5 2.5 2-61 Permanent installation indoors,
in cable ditches or pipes where shielding is required
4 6 2-14
10 2-10
KVVP2 Copper Conductor,
PVC Insulated and Sheathed,Copper-tape Screened Control Cable
0.75 1.0 1.5 2.5 4-10 Permanent installation indoors,
in cable ditches or pipes where shielding is required
4 6 7-61
10 4-10
KVV22 Copper Conductor,
PVC Insulated and Sheathed,Steel tape Armored Control Cable
0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,in cable ditches,
Be able to withstand stronger external mechanical force
4 6 4-14
10 4-14
KVVR Copper Conductor,
PVC Insulated and Sheathed,Flexible Control Cable
0.5-2.5 4-61 Installation indoors where flexibility and movability are required
KVVRP Copper Conductor,
PVC Insulated and Sheathed,
Braiding shielded Flexible Control Cable
0.5 0.75 1.0 4-61 Installation indoors where flexibility shielding and movability are required
1.5 2.5 4-48
KYJV CopperConductor,
XLPE Insulated and PVC Sheathed Control Cable
0.75 1.0 1.5 2.5 2-16 Permanent installation indoors,in cable ditches or pipes
4 6 2-14
10 2-10
KYJVP Copper Conductor,
XLPE Insulated,Braiding Shielded,
PVC Sheathed Control Cable
0.75 1.0 1.5 2.5 2-61 Permanent installation indoors,in cable ditches
or pipes where shielding is required
4 6 2-14
10 2-10
KYJV22 CopperConductor,XLPE Insulated,Steel-tape Armoured,
PVCSheathed Control Cable
0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,in cable ditches,
pipes or underground Be cable to with stand stronger external mechanical force
4 6 4-14
10 4-10
KYJVP2 CopperConductor,XLPE Insulated,Copper tape Screened,
PVCSheathed Control Cable
0.75 1.0 1.5 2.5 7-61 Permanent installation indoors,
in cable ditches or pipes where shielding is required
4 6 4-14
10 4-10
KYJVR CopperConductor,XLPE Insulated,
PVCSheathed Flexible Control Cable
0.5-2.5 4-61 Installation indoors where flexibility and movability are required
KYJVRP CopperConductor,XLPE Insulated,Braiding Shielded,
PVC Sheathed Flexible Control Cable
0.5 0.75 1.0 4-61
1.5 2.5 4-48 Installation indoors where flexibility shielding and movability are required
Tags: , ,