LV, Three Core Armored Cable, 3X4mm2

LV, Three Core Armored Cable, 3X4mm2
3x4mm2 BM8
Underground
Low and Medium Voltage Cable
DC & AC
PVC
PVC
Round Wire
Bare Copper Wire
ISO, CCC, CE, RoHS, UL, VDE
VV32
Yifang
SGS
Yifang Cable
Wooden or Wooden-Steel Drum
3x4mm2
Zhengzhou, China
8544601200

Product Description

3x4mm2 600/1000V IEC 60502-1 CU / PVC / SWA / PVC Power Cable
We manufacture VV32 series of PVC insulated galvanized steel wire armoured copper cables for power transmission and
distribution. IEC 60502-1, 600/1000 Volts, 70°C, Polyvinyl Chloride (PVC) insulation, galvanized steel wire armoured, and Polyvinyl
Chloride (PVC) sheathed, stranded copper conductor as per IEC 60228 class 2, flame retardant to IEC 60332-1 vertical flame
propagation test. And a variety of international standards are availble. We provide a high standard of quality control and manufacturing
with our main markets all over the world. Please feel free to contact us for latest prices. We will respond to you immediately!

1. Conductor: Circular Stranded Annealed Copper
2. Conductor Type: As per IEC 60228 / BS EN 60228, Class 2
3. Conductor Size: 2.5~35mm2 (13~2 awg)
4. Conductor Counts: 3 Cores (Triplex)

5. Insulation: Polyvinyl Chloride (PVC)
6. Insulation Colours: Black, Light Blue, Brown, Grey, Green/Yellow, or Other Colours
7. Armour: Galvanized Steel Wire Armour
8. Sheath: Polyvinyl Chloride (PVC/ST2)
9. Sheath Colours: Black, or Other Colours
10. Rated Voltage: 600/1000 Volts (600 Volts between Line-to-Earth, 1000 Volts between Line-to-Line, Circuit Voltage not Exceeding
1,200 Volts)
11. Maximum Conductor Temperature: 70°C
12. Maximum Short-Circuit Temperature: 160°C 5s
13. Testing Voltage: 3,500 Volts
14. Flame Retardant: As per IEC 60332-1 Vertical Flame Propagation Test
15. Application: For Installation in Open Tray, Conduit and Underground Duct Trench, or Direct Burial in Ground, Dry or Wet Locations
For more details please refer to Technical Data.

Type Description Application n
Cu Al
YJV YJLV XLPE insulation PVC sheath power cable To be laid indoors, in tunnel, cable furrow or pipe, the cable couldn’t bear mechanical force outside
YJY YJLY XLPE insulation PE sheath power cable
YJV22 YJLV22 XLPE insulation, steel tape armor, PVC sheath power cable To be laid underground, the cable could bear certain mechanical force, but it couldn’t bear great pulling force.
YJV23 YJLV23 XLPE insulation, steel tape armor, PE sheath power cable
YJV62 YJLV62 XLPE insulation, have no the magnetism steel tape armor, PE sheath power cable
YJV32 YJLV32 XLPE insulation, thin steel-wire armor, PVC sheath power cable Be applicable to the well, water inside and fall in the bad soil, the cable cans bear the equal dint outside the machine with pull the dint
.
YJV72 YJLV72 XLPE insulation, have no the magnetism thick steel-wire armor, PVC sheath power cable
YJV42 YJLV42 XLPE insulation, thick steel-wire armor, PVC sheath power cable Be applicable to the well, underwater with the bottom of sea, the cable cans bear the bigger pressure with lead to pull the dint.
U0/Um(kv)
No.of Core
1st class 0.6/1kv 1.8/3kv 3.6/6kv 6/10kv 8.7/15kv 12/20kv 18/30kv 21/35kv
2nd class 1/1kv 3/3kv 6/6kv 8.7/10kv 12/15kv 18/20kv 26/35kv
1 Core Section
area(mm2)
1.5-800 25-800 25-800 25-800 35-800 50-800 50-800 50-800
2 Core Section
Area(mm2)
1.5-185 / / / / / / /
3 Core Section
area(mm2)
1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400
4 Core Section
Area(mm2)
2.5-400 25-400 / / / / / /
5 Core Section
area(mm2)
2.5-400 25-400 / / / / / /