Low Voltage XLPE Insulation Underground Copper Power Cable with Swa Armored

Low Voltage XLPE Insulation Underground Copper Power Cable with Swa Armored
YJV32, YJV22, YJV, YJLV
Underground, Industrial, Power Station
Low and Medium Voltage Cable
DC Cable
XLPE
PVC
Round Wire
Bare Copper Wire
ISO, CCC, CE
YJV
Jinshui
Jinshui
Wooden drum, Iron wooden drum, Iron drum
ASTM, IEC, BS, ICEA
China
8544492900

Product Description

low voltage XLPE insulation underground copper power cable with SWA armored

Medium Voltage single core XLPE Insulated Steel Wire Armored PVC Sheathed Electrical power cable

All type of Medium Voltage XLPE Insulated PVC Sheathed Power Cable :
1). 3.6/6(7.2)kV,3.6/6.6(7.2)kV, Single Core, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
2). 6/10(12)kV,6.35/11(12)kV, Single Core, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
3). 8.7/10(15)kV, Single Core, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
4). 12/20(24)kV, 12.7/22(24)kV, Single Core, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
5). 18/30(36)kV,19/33(36)kV, Single Core, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
6). 3.6/6(7.2)kV,3.6/6.6(7.2)kV, Three Cores, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
7). 6/10(12)kV,6.35/11(12)kV, Three Cores, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
8). 8.7/10(15)kV, Three Cores, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
9). 12/20(24)kV, 12.7/22(24)kV, Three Cores, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.
10). 18/30(36)kV,19/33(36)kV, Three Cores, Al or Cu/XLPE/CTS/PVC Un-armoured Power Cable.

Application:
Medium Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 3.6kv~35kV . It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.

Property:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds),the highest temperature for conductor is no more than 250 degrees.
3.the environmental temperature of operating in air should be no more than 40 degrees, and 25 degrees underground.
4.Excellent electrical performance, resistance to chemical corrosion.

It shows us the most common sizes of non armoured power cable, but other sizes to any recognized standards or customer specification can also be supplied as per customer’s requirements.