Low Voltage PVC Insulation Nyy Power Cable Copper Conductor
More product about CableProduct Description
Low Voltage PVC Insulation NYY Power Cable Copper Conductor
1.Product description of power cable
NYY Power Cable 0.6/1 kV Low Voltage Cable 5x70mm2 applies to electrical power transmission and distribution lines with AC rated voltage Uo/ U up to and including 0.6/1kV.For outdoor and indoor installation in damp and wet locations,laid directly in the ground(when well protect in ducts,in trenches and in steel support brackets.
1.U0/U: 0.6/1kV
2.Standard: IEC60502, BS7870,GB/T12706
3.Max. working temperature: 70 °C , can be 90 °C and 110 °C as requirement
4.Conductor: Class 1/2 annealed bare copper solid or stranded
5.Insulation: PVC
6. Sheath: PVC
7. Cores: 1~5 cores,3C+1E,4C+1E,3C+2E
8. Cross section area: 1.5~630mm²
9.Packing:Wooden drum or as requirement
10.Certification : ISO9001/ISO14001 /OHSAS18001/CCC/CE/CB
11.Remark: Flame retardant,fire resistance,low smoking and Halogen free,or other property can be avaliable
2.Technical Data power cable
U0/Um(kv) | 1st class | 0.6/1kv | 1.8/3kv | 3.6/6kv | 6/10kv | 8.7/15kv | 12/20kv | 18/30kv | 21/35kv |
No.of Core | |||||||||
1 Core | Section | 1.5-800 | 25-800 | 25-800 | 25-800 | 35-800 | 50-800 | 50-800 | 50-800 |
area(mm2) | |||||||||
2 Core | Section | 1.5-185 | / | / | / | / | / | / | / |
Area(mm2) | |||||||||
3 Core | 1.5-400 | 25-400 | 25-400 | 25-400 | 35-400 | 50-400 | 50-400 | 50-400 | |
4 Core | Section | 2.5-400 | 25-400 | / | / | / | / | / | / |
Area(mm2) |
Four cores:
cross section mm2 | insulated thickness mm | sheath thickness mm | outer diameter mm | testing voltage kv | current loading capacity | |
in the air | to be laid underground | |||||
1.5 | 0.7 | 1.5 | 10.6 | 3.5 | 21 | 25 |
2.5 | 0.7 | 1.5 | 11.5 | 3.5 | 28 | 33 |
4 | 0.7 | 1.5 | 12.8 | 3.5 | 37 | 44 |
6 | 0.7 | 1.5 | 14 | 3.5 | 46 | 54 |
10 | 0.7 | 1.5 | 15.9 | 3.5 | 63 | 73 |
16 | 0.7 | 2 | 19.1 | 3.5 | 84 | 94 |
25 | 0.9 | 2 | 22.7 | 3.5 | 109 | 120 |
35 | 0.9 | 2 | 25.4 | 3.5 | 132 | 144 |
50 | 1 | 2 | 29 | 3.5 | 159 | 169 |
70 | 1.1 | 2 | 32.9 | 3.5 | 195 | 205 |
95 | 1.1 | 2.5 | 37.7 | 3.5 | 237 | 245 |
120 | 1.2 | 2.5 | 41.6 | 3.5 | 273 | 278 |
150 | 1.4 | 3 | 47.6 | 3.5 | 310 | 309 |
185 | 1.6 | 3 | 50.6 | 3.5 | 355 | 347 |
240 | 1.7 | 3 | 56.4 | 3.5 | 416 | 399 |
300 | 1.8 | 3.5 | 62.2 | 3.5 | 473 | 446 |
400 | 2 | 3.5 | 68.9 | 3.5 | 512 | 43 |
3+1 cores:
cross section mm2 | insulated thickness mm | sheath thickness mm | outer diameter mm | testing voltage kv | current loading capacity | |
in the air | to be laid underground | |||||
1.5 | 0.7 | 1.5 | 10.6 | 3.5 | 21 | 25 |
2.5 | 0.7 | 1.5 | 11.5 | 3.5 | 28 | 33 |
4 | 0.7 | 1.5 | 12.5 | 3.5 | 37 | 44 |
6 | 0.7 | 1.5 | 13.7 | 3.5 | 46 | 54 |
10 | 0.7 | 1.5 | 15.4 | 3.5 | 63 | 73 |
16 | 0.7 | 2 | 17.5 | 3.5 | 84 | 94 |
25 | 0.9 | 2 | 21.8 | 3.5 | 109 | 120 |
35 | 0.9 | 2 | 23.8 | 3.5 | 132 | 144 |
50 | 1 | 2 | 27.4 | 3.5 | 159 | 169 |
70 | 1.1 | 2 | 31 | 3.5 | 195 | 205 |
95 | 1.1 | 2.5 | 34.8 | 3.5 | 237 | 245 |
120 | 1.2 | 2.5 | 39.7 | 3.5 | 273 | 278 |
150 | 1.4 | 3 | 42.9 | 3.5 | 310 | 309 |
185 | 1.6 | 3 | 52.7 | 3.5 | 355 | 347 |
240 | 1.7 | 3 | 58 | 3.5 | 416 | 399 |
300 | 1.8 | 3.5 | 62.2 | 3.5 | 473 | 446 |
400 | 2 | 3.5 | 68.9 | 3.5 | 512 | 431 |