Kvvp Copper PVC/PVC Copper Wire Shielded Control Cable
Product Description
Used as power and connecting cables in mechanical engineering for tooling machinery, control unit, production lines, transportation equipment, conveyor and assembly lines as well as in plant construction under the circumstance that the rated voltage is up to 450/750V AC.
2. Character and Relevant Parameters
1. Long-term service temperature of the cable conductor: 70 0C
2. Rated voltage: 450/750V
3. Cable lying temperature ≥ 0 0C
4. Cores: 2, 3, 4, 5, 6, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52, 61
5. Minimun bending radius:
Non armored ≥ Out diameter of cable 6 times
Armored layer or copper tape shielded ≥ Outer diameter of cable 12 times
Shielded layer soft cable ≥ Outer diameter of cable 6 times
3. Type (see following table)
PVC insulated control cable
XLPE insulated control cable
4. Type (see following table)
Type | Name | Section Area (mm2) | No.of Core | Application Site |
KVV | CopperConductor,PVC Insulated and Sheathed Control Cable | 0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP | Copper Conductor, PVC Insulated and Sheathed,Braiding Shielded Control Cable |
0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KVVP2 | Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable |
0.75 1.0 1.5 2.5 | 4-10 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 7-61 | |||
10 | 4-10 | |||
KVV22 | Copper Conductor, PVC Insulated and Sheathed, Steel tape Armored Control Cable |
0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches, Be able to withstand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-14 | |||
KVVR | Copper Conductor, PVC Insulated and Sheathed,Flexible Control Cable |
0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KVVRP | Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable |
0.5 0.75 1.0 | 4-61 | Installation indoors where flexibility shielding and movability are required |
1.5 2.5 | 4-48 | |||
KYJV | CopperConductor, XLPE Insulated and PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 | 2-16 | Permanent installation indoors,in cable ditches or pipes |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJVP | Copper Conductor, XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable |
0.75 1.0 1.5 2.5 | 2-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 2-14 | |||
10 | 2-10 | |||
KYJV22 |
CopperConductor,XLPE Insulated,Steel-tape Armoured, PVCSheathed Control Cable |
0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVP2 | CopperConductor,XLPE Insulated, Copper tape Screened,PVCSheathed Control Cable |
0.75 1.0 1.5 2.5 | 7-61 | Permanent installation indoors,in cable ditches or pipes where shielding is required |
4 6 | 4-14 | |||
10 | 4-10 | |||
KYJVR | CopperConductor,XLPE Insulated, PVCSheathed Flexible Control Cable |
0.5-2.5 | 4-61 | Installation indoors where flexibility and movability are required |
KYJVRP | CopperConductor,XLPE Insulated,Braiding Shielded, PVC Sheathed Flexible Control Cable |
0.5 0.75 1.0 | 4-61 | |
1.5 2.5 | 4-48 | Installation indoors where flexibility shielding and movability are required |
- Next: 450/750V 600/1000V Braided Shielding PVC Mechanical Control Cable
- Previous: Multi Core Control XLPE Insulated Power Cable
Contact us
Similar Or Related
-
10X1.5mm2 Flame Retardant Copper Tape Screen Steel Tape Armored PVC Sheathed Control Cable 0.6/1kV
-
JZ-500 Flexible Copper Control Cable PVC Insulated 300/500V DIN VDE 0285-525
-
0.3/0.5kV 4X4mm2 Copper Wire Braiding PVC Insulation Low Voltage Control Power Cable
-
24X2.5mm2 XLPE Insulated Steel Tape Armoured Control/Instrumentation Cable IEC 60502-1