IEC60502-2 XLPE Insualted Armoured Underground 6/10kv Copper Cable 3*240mm2

IEC60502-2 XLPE Insualted Armoured Underground 6/10kv Copper Cable 3*240mm2
YJV32
Jinyuan
ISO9001, CCC
Flame Retardant
Round Wire
XLPE
PVC
Copper
Underground
Stranded
Insulated
Jinyuan
Iron Wooden
25mm2-800mm2
China

Product Description

Wholesale Power Electric Cable With XLPE Insulated 
Technical Parameters of our Power Cable 
1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890
2). Detailed description or construction:
   * Conductor: compacted or uncompacted copper or aluminium
   * Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
   * Filler: Polypropylene filament with lapped binding tape
   * Binder: Binding tape
   * Inner sheath: Polyvinyl chloride (PVC)
   * Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
   *Sheath: Polyvinyl chloride (PVC)
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
   U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV
4). Voltage:
    0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV
   In the voltage designation of cables U0/U(Um):
       * U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
       * U is the rated power frequency voltage between conductors for which the cable is designed;
       * Um is the maximum value of the "highest system voltage" for which the equipment maybe used.
5). Application:
    For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.
6). Marking: According to the customers’ requirements
7). Nominal cross-sectional areas:
1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2
 
Type Designation Applications
VV
YJV
VLV
YJLV
Copper conductor, PVC ,XLPE insulated, PVC sheathed power cable
Aluminium conductor, PVC ,XLPE  insulated, PVC sheathed power cable
For laying indoors, in tunnel or cable trench, unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct.
VY
YJY
VLY
YJLY
Copper conductor, PVC,XLPE insulated, PE sheathed power cable
Aluminium conductor, PVC ,XLPE insulated, PE sheathed power cable
VV22
YJV22
VLV22
YJLV22
Copper conductor, PVC ,XLPE insulated, steel tape armoured, PVC sheathed power cable
Aluminium conductor, PVC ,XLPE  insulated, steel tape armoured, PVC sheathed power cable
For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force.
VV23
YJV23
VLV23
YJLV23
Copper conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable
Aluminium conductor, PVC ,XLPE insulated, steel tape armoured, PE sheathed power cable
VV32
YJV32
VLV32
YJLV32
Copper conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable
Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PVC sheathed power cable
For laying indoors, in tunnel, in cable trench or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force.
VV33
YJV33
VLV33
YJLV33
Copper conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable
Aluminium conductor, PVC ,XLPE insulated, steel wire armoured, PE sheathed power cable
Note: The armoured single core cables is only used for D.C. system. As for A.C. system, non-magnetic armour material should be applied.

NOTE:
If you want to know more details about this kind of products, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.
Welcome to our factory , our website:htcable.cn