Hv Aluminum Conductor XLPE Insulated Electric Cable with 3 Cores

Hv Aluminum Conductor XLPE Insulated Electric Cable with 3 Cores
YJLV
Construction, Underground, Industrial, Power Station
High Voltage Cable
DC Cable
XLPE
PVC
Round Wire
Bare Copper Wire
ISO, CCC, CE
Yjlv
Jytop
High Voltage 26/35kv
Factory
Aluminum
XLPE
PVC
3
Ce,ISO,CCC
IEC60502-2
by Drums
as Request
JYTOP
Packed in Drums
as client' s request
Zhengzhou, China
8544601200

Product Description

High Voltage Hv 26/35kv Aluminum Conductor XLPE INSULATED Electric Cable with 3 Cores

26/35kV AL/XLPE/PVC(or PE) Power Cable
1. Description
Construction:Hv Aluminum Conductor XLPE insulated electric cable with 3 cores has Compacted stranded circular aluminum conductor, extruded semi-conducting compound as conductor shield, cross-linked polyethylene (XLPE) insulation, semi-conducting compound as insulation shield, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.

2. Operating Characteristics
Rated voltage U0/U(Um): 26/35(40.5)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cable is designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Max. Permissible continuous operating temperature of conductor: 90 ° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed: 250 ° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For three core cable: Not less than 15 times of the diameter of cable

3. Application
This hv aluminum conductor XLPE insulated electric cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.

4. Manufacturing Standards IEC 60502-2 and Chinese National Standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.

NOTE:
If you want to know more details about this hv aluminum conductor XLPE insulated electric cable, please visit our website(homepage) because we have no ways to show so much information on this platform. Thank you.

Size Nominal thickness of XLPE insulation(mm) Approx. thickness of copper tape screen (mm) Nominal thickness of PVC or PE(mm) Approx. overall diameter of finished cable(mm) Max. conductor D.C resistance @ 20ºC(Ω/km)
3x50mm 2 10.5 0.10 3.5 81.4 0.641
3x70mm 2 10.5 0.10 3.6 85.3 0.443
3x95mm 2 10.5 0.10 3.7 89.1 0.320
3x120mm 2 10.5 0.10 3.8 92.3 0.253
3x150mm 2 10.5 0.10 3.9 96.1 0.206
3x185mm 2 10.5 0.10 4.0 99.8 0.164
3x240mm 2 10.5 0.10 4.2 105.4 0.125
3x300mm 2 10.5 0.10 4.4 110.2 0.100
3x400mm 2 10.5 0.10 4.6 117.7 0.0778
Tags: , ,

Similar Or Related

  • No related articles




  • Please enter your first and last name separated by a space (e.g. Jane Miller)




    Success! Thanks for Your Request.
    Error! Please Try Again.