Fire Retardant Exav-F2 3X16 + 1X10 Underground Armoured Power Cables

Fire Retardant Exav-F2 3X16 + 1X10 Underground Armoured Power Cables
exav cable
Construction, Underground, Industrial, Power Station
Low and Medium Voltage Cable
DC & AC
XLPE
PVC
Round Wire
Bare Copper Wire
ISO, CCC
Eaxvb 1kv
OEM
Cable Channel, Tube, Underground, Open Air
Hongda
500m or 1000m Per Drum, or Customized
3×16+1×10
China
8544492100

Product Description

Fire retardant EXAV-F2 3×16 + 1×10 underground Armoured power cables

Description
Reinforced energy cables for underground household and industrial where there is a risk of mechanical damage. Non-fire spreading (F2)

STANDARDS
National: NBN HD 603 Part 6 / Sect.E
DESCRIPTION
DESCRIPTION
White copper core solid (Class 1) or fused together (Class 2)
XLPE conductor insulation (X)
Safety circuit made of bare copper wires (*)
Steel bands or wires (A)
PVC jacket (V) – color: black
(*) Suitable as earthing for conductors up to and including 6 mm²

COLOR CODE
2 x: blue, brown
3 x: brown, black, gray
3G: green / yellow, blue, brown
3 + 1 x: brown, black, gray + blue
3 + 1 G: brown black, gray + green / yellow
4 x: blue, brown, black, gray
4 G: green / yellow, brown, black, gray

INSTALLATION
In cable channel
In tube
Underground with or without protection
In open air
In industry
In homes

CONSTRUCTION CHARACTERISTICS

Composition conductor Copper Conductor flexibility class 2
Conductor shape Round, joined together
Insulation XLPE
Reinforcement Steel tape
Outer jacket PVC

MEASURING CHARACTERISTICS

Number of conductors 4
Diameter conductor 16mm2
Average thickness of the insulation (mm) 0.7mm
Thickness of the steel tape 0.5mm
Section of the reduced neutral 10mm2
Approximate weight 1260kg/km

ELECTRIC CHARACTERISTICS

Nominal voltage Uo / U (Um) 0.6 / 1 kV
Operating voltage 1kV
Permissible current in open air 100A
Permissible current (underground) 120A
Ohmic resistance of the armament 2.0 Ohm / km

USE CHARACTERISTICS
Chemical resistance Average
Non-fire-spreading: NBN C 30-004-F2
Maximum conductor temperature in operation: 90 ° C
Operating temperature, range: -5 .. 60 ° C

Vibration resistance Average
Bending radius at placement: 15 (xD)
Minimum temperature at installation: 5 ° C

 

More information and other cable inquiry, pls contact us as follows:

Vivian Yuan
Mobile: +86 18339931106 

Tags: , ,

Similar Or Related





Please enter your first and last name separated by a space (e.g. Jane Miller)




Success! Thanks for Your Request.
Error! Please Try Again.