Cu/XLPE/Cts/PVC/Sta/PVC, Power Cable, 8.7/15 (17.5) Kv, 3/C (IEC 60502-2)
Product Description
The cable design conforms to IEC 60502 part 2. However if requested, we can separately offer guaranteed technical particulars for cables as per different international specifications or specific customer needs.
CONSTRUCTIONAL FEATURES
Conductor
Copper Conductors upto 1000 sq mm will be circular compacted & stranded and shall comply with IEC-60228 Class 2.
Conductor screen
This will be an extruded layer of semiconducting XLPE applied under simultaneous triple extrusion process over the conductor along with the insulation and the insulation screen.
Insulation
This will be an extruded layer of insulating grade XLPE applied over conductor screen under triple extrusion process along with conductor screen and insulation screen.
Insulation screen
This will be a layer of semiconducting XLPE which will be applied by tripe extrusion process over the insulation.
Metallic screen
It will consist of a layer of copper wires applied helically with overlap over insulation screen. Other combinations of metallic screens as per customer’s requirement can also be provided on request.
Inner Sheath (Bedding)
Extruded layer of PVC or PE is applied over the laid-up cores. PVC is normally of grade ST2 or PE of grade ST7 as per IEC 60502 Part 2.
Armour
The armour is applied over inner sheath. For Single core cables this is of aluminium wires and for multicore cables the armour can be of one among the following options: –
A) Galvanized steel wire.
B) Galvanized steel tape.
C) Galvanised steel strip.
The armour is applied helically over the bedding.
Outer sheath
An extruded layer is applied over the armour in case of armoured cables and over the laid up cores in case of unarmoured cables. Outer sheath material can be either PVC of grade ST2 or PE of grade ST7 as per IEC-60502 Part 2.
Section | Conductor diameter | Conductor weight | Insulation thickness | Bedding thickness | Steel tape thickness | Outer sheath thickness | Cable overall diameter | Cable weight | Minimum bending radius of cable (During installation) | DC resistance of conductor at 20 °C (Maximum) |
mm2 | mm | kg/km | mm | mm | mm | mm | mm | kg/km | mm | ohm/km |
25 | 5.9 | 665 | 4.5 | 1.4 | 0.5 | 2.5 | 47.5 | 3000 | 713 | 0.727 |
35 | 6.9 | 922 | 4.5 | 1.4 | 0.5 | 2.6 | 50.0 | 3435 | 750 | 0.524 |
50 | 8.1 | 1242 | 4.5 | 1.5 | 0.5 | 2.7 | 53.0 | 3990 | 795 | 0.387 |
70 | 9.7 | 1800 | 4.5 | 1.5 | 0.5 | 2.8 | 56.5 | 4805 | 848 | 0.268 |
95 | 11.4 | 2500 | 4.5 | 1.6 | 0.5 | 2.9 | 60.5 | 5835 | 908 | 0.193 |
120 | 12.9 | 3152 | 4.5 | 1.7 | 0.5 | 3.0 | 64.0 | 6800 | 960 | 0.153 |
150 | 14.3 | 3888 | 4.5 | 1.7 | 0.5 | 3.1 | 67.0 | 7795 | 1005 | 0.124 |
185 | 16.0 | 4875 | 4.5 | 1.8 | 0.5 | 3.3 | 71.5 | 9175 | 1073 | 0.0991 |
240 | 18.4 | 6410 | 4.5 | 1.9 | 0.5 | 3.4 | 77.0 | 11215 | 1155 | 0.0754 |
300 | 20.6 | 8039 | 4.5 | 2.0 | 0.8 | 3.6 | 83.5 | 14185 | 1253 | 0.0601 |
400 | 23.3 | 10301 | 4.5 | 2.1 | 0.8 | 3.9 | 91.0 | 17330 | 1365 | 0.0470 |
- Next: 2491X, Electric Wire, 450/750 V, Flexible Cu/PVC (BS 6004)
- Previous: Nyaf, Electric Wire, 450/750 V, Class 5 Cu/PVC (VDE 0281-3)
Contact us
Similar Or Related
-
15kV 3 Core 4/0AWG Aluminum Conductor XLPE Insulated SWA Armored MV Power Cable
-
XLPE Insulated Aerial Service Drop Cable Conductor #3AWG Duplex ICEA S-66-524 NEMA WC7
-
3Cx185mm2 XLPE Insulated Copper Tape Screened Galvanized Steel Wire Armored Power Cable 33kV
-
0.6/1kV 4Cx500mm2 Copper Conductor PVC Insulated SWA Armored LV Power Cable IEC 60502-1
-
Low Voltage Single Core Power Cable 1X300 mm2 N2XCH CU/XLPE/CWS/LSF 0.6/1kV
-
Cu/XLPE/Cts/PVC/Sta/PVC, Power Cable, 8.7/15 (17.5) Kv, 3/C (IEC 60502-2)