Cu/XLPE/Cts/PVC/Awa/PVC, Power Cable, 3.6/6 (7.2) Kv, 1/C (IEC 60502-2)

Cu/XLPE/Cts/PVC/Awa/PVC, Power Cable, 3.6/6 (7.2) Kv, 1/C (IEC 60502-2)
CU/XLPE/CTS/PVC/AWA/PVC
Underground, Industrial, Power Station
Low and Medium Voltage Cable
DC Cable
XLPE
PVC
Round Wire
Bare Copper Wire
ISO, CCC
Cu/XLPE/Cts/PVC/Awa/PVC
Boan
3.6/6 (7.2) Kv
2
1
25-1000 mm2
Aluminum Wire Armour
DingAn
Heated Steel-Wooden Drum/Steel Drum
SGS
Jiangsu Yixing, China
8544601200

Product Description

CU/XLPE/CTS/PVC/AWA/PVC, Power Cable, 3.6/6 (7.2) KV, 1/C (IEC 60502-2)
The cable design conforms to IEC 60502 part 2. However if requested, we can separately offer guaranteed technical particulars for cables as per different international specifications or specific customer needs.

CONSTRUCTIONAL FEATURES

Conductor
Copper Conductors upto 1000 sq mm will be circular compacted & stranded and shall comply with IEC-60228 Class 2.

Conductor screen
This will be an extruded layer of semiconducting XLPE applied under simultaneous triple extrusion process over the conductor along with the insulation and the insulation screen.

Insulation
This will be an extruded layer of insulating grade XLPE applied over conductor screen under triple extrusion process along with conductor screen and insulation screen.

Insulation screen
This will be a layer of semiconducting XLPE which will be applied by tripe extrusion process over the insulation.

Metallic screen
It will consist of annealed copper tape or a layer of copper wires applied helically with overlap over insulation screen. Other combinations of metallic screens as per customer’s requirement can also be provided on request.

Inner Sheath (Bedding)
Extruded layer of PVC or PE is applied over the laid-up cores. PVC is normally of grade ST2 or PE of grade ST7 as per IEC 60502 Part 2.

Armour

The armour is applied over inner sheath. For Single core cables this is of aluminium wires.
A) Galvanized steel wire.
B) Galvanized steel tape.
C) Galvanised steel strip.
The armour is applied helically over the bedding.

Outer sheath
An extruded layer is applied over the armour in case of armoured cables and over the laid up cores in case of unarmoured cables. Outer sheath material can be either PVC of grade ST2 or PE of grade ST7 as per IEC-60502 Part 2.

Section Conductor diameter Conductor weight Insulation thickness Bedding thickness Armour wire diameter Outer sheath thickness Cable overall diameter Cable weight Minimum bending radius of cable DC resistance of conductor at 20 °C Armour DC resistance at 20 °C Short circuit current rating of armour for 1 second
mm2 mm kg/km mm mm mm mm mm kg/km mm ohm/km ohm/km kA
25 5.9 218 2.5 1.2 1.6 1.8 21.5 740 323 0.727 0.607 4.27
35 6.9 303 2.5 1.2 1.6 1.8 22.5 855 338 0.524 0.584 4.44
50 8.1 408 2.5 1.2 1.6 1.8 24.0 1005 360 0.387 0.542 4.78
70 9.7 591 2.5 1.2 1.6 1.8 25.5 1245 383 0.268 0.490 5.29
95 11.4 821 2.5 1.2 1.6 1.9 27.5 1550 413 0.193 0.447 5.80
120 12.9 1035 2.5 1.2 1.6 1.9 29.0 1820 435 0.153 0.410 6.32
150 14.3 1277 2.5 1.2 1.6 2.0 30.5 2120 458 0.124 0.389 6.66
185 16.0 1601 2.5 1.2 2.0 2.0 33.0 2590 495 0.0991 0.294 8.80
240 18.4 2105 2.6 1.2 2.0 2.1 36.0 3225 540 0.0754 0.263 9.87
300 20.6 2640 2.8 1.2 2.0 2.2 38.5 3895 578 0.0601 0.237 10.94
400 23.3 3383 3.0 1.2 2.0 2.3 42.5 4845 638 0.0470 0.211 12.27
500 26.3 4272 3.2 1.3 2.5 2.5 47.5 6115 713 0.0366 0.155 16.67
630 30.0 5618 3.2 1.4 2.5 2.6 51.5 7625 773 0.0283 0.138 18.75
800 34.2 7286 3.2 1.4 2.5 2.7 56.5 9465 848 0.0221 0.124 20.84
1000 38.2 9046 3.2 1.5 2.5 2.9 61.0 11530 915 0.0176 0.113 22.92

Tags: , ,

Similar Or Related





Please enter your first and last name separated by a space (e.g. Jane Miller)




Success! Thanks for Your Request.