Concentric Cable 1/0 2/0 3/0 4/0AWG
More product about Concentric CableConcentric Cable 1/0 2/0 3/0 4/0AWG
Concentric Cable
Overhead, Industrial
Low and Medium Voltage Cable
AC Cable
XLPE
PVC
Round Wire
Aluminium or Copper Conductor
ISO, CCC, CE, UL
Concentric Cable
Yifang
ISO;Ce;UL;Kema
Yifang
Wood Packing by Sea
1000meter per drum
China
8544492100
Product Description
Application
Concentric cables are commonly used for power distribution network, ammeter panel, instrument or circuit panel, which can be laid directly underground or outdoors and even applicable in dry and wet conditions.
Construction
- Conductor: Class 2 copper conductor or 8000 series aluminum alloy
- Insulation: XLPE insulation
- Cable inner sheath: PVC
- Concentric layer: Copper/8000 series aluminum alloy
- Cable wrapping tape: Non-absorbent material
- Cable sheath: PVC (XLPE/PE) sheath
Standard
IEC60502-1, BS7870, ASTMD2655
ASTMB556, ASTMB193, ASTMB8, UL44, UL1581, UL854
ASTM Standard
Core and nominal cross section | Conductor | Insulation thickness | Concentric conductor | Thickness of cable shield | . | Cable weight/km | Max DC resistance of conductor (20ºC) | |||
Wire gauge | Number | Diameter mm | mm | Number | Diameter mm | mm | mm | kg/km | Ω/km () | Ω/km (Concentric) |
Copper conductor (US standard) | ||||||||||
2X #12 | 7 | 0.78 | 1.14 | 39 | 0.321 | 1.14 | 7.74 | 108 | 5.43 | 5.50 |
2X #10 | 7 | 0.98 | 1.14 | 25 | 0.511 | 1.14 | 8.72 | 151 | 3.41 | 3.50 |
2X #8 | 7 | 1.23 | 1.14 | 25 | 0.643 | 1.14 | 9.74 | 214 | 2.14 | 2.20 |
2X #6 | 7 | 1.55 | 1.14 | 25 | 0.813 | 1.14 | 11.04 | 313 | 1.35 | 1.40 |
2X #4 | 7 | 1.96 | 1.14 | 26 | 1.020 | 1.14 | 12.68 | 472 | 0.848 | 0.85 |
3X #8 | 7 | 1.23 | 1.14 | 65 | 0.405 | 1.14 | 11.3X17.3 | 418 | 2.14 | 2.20 |
3X #6 | 7 | 1.55 | 1.14 | 65 | 0.511 | 1.52 | 13.2X20.2 | 620 | 1.35 | 1.40 |
3X #4 | 7 | 1.96 | 1.14 | 65 | 0.643 | 1.52 | 14.7X22.9 | 875 | 0.848 | 0.85 |
3X #2 | 7 | 2.47 | 1.14 | 65 | 0.823 | 1.52 | 16.6X26.3 | 1275 | 0.524 | 0.53 |
Aluminum alloy conductor (US standard) | ||||||||||
2X #12 | 7 | 0.78 | 1.14 | 39 | 0.321 | 1.14 | 7.74 | 67 | 8.88 | 8.90 |
2X #10 | 7 | 0.98 | 1.14 | 25 | 0.511 | 1.14 | 8.72 | 85 | 5.59 | 5.60 |
2X #8 | 7 | 1.23 | 1.14 | 25 | 0.643 | 1.14 | 9.74 | 110 | 3.52 | 3.60 |
2X #6 | 7 | 1.55 | 1.14 | 25 | 0.813 | 1.14 | 11.04 | 148 | 2.21 | 2.30 |
2X #4 | 7 | 1.96 | 1.14 | 26 | 1.020 | 1.14 | 12.68 | 206 | 1.39 | 1.40 |
3X #8 | 7 | 1.23 | 1.14 | 65 | 0.405 | 1.14 | 11.3X17.3 | 262 | 3.52 | 3.60 |
3X #6 | 7 | 1.55 | 1.14 | 65 | 0.511 | 1.52 | 13.2X20.2 | 370 | 2.21 | 2.30 |
3X #4 | 7 | 1.96 | 1.14 | 65 | 0.643 | 1.52 | 14.7X22.9 | 488 | 1.39 | 1.40 |
3X #2 | 7 | 2.47 | 1.14 | 65 | 0.823 | 1.52 | 16.6X26.3 | 640 | 0.88 | 0.89 |
IEC Standard
Core and nominal cross section | Conductor | Insulation thickness | Concentric conductor | Thickness of cable shield | . | Weight of cable/km | Max DC resistance of conductor (20ºC) | ||||
mm2 | Number | Diameter mm | mm | Number | Diameter mm | mm | mm | kg/km | Ω/km () | Ω/km (Concentric) | |
Copper conductor (IEC standard) | |||||||||||
2X10 | 7 | 1.35 | 1.55 | 20 | 0.85 | 1.40 | 11.80 | 290 | 1.83 | 1.90 | |
2X16 | 7 | 1.70 | 1.55 | 32 | 0.85 | 1.40 | 12.84 | 420 | 1.15 | 1.20 | |
2X25 | 7 | 2.14 | 1.60 | 29 | 1.13 | 1.50 | 15.02 | 630 | 0.727 | 0.76 | |
2X35 | 19 | 1.53 | 1.65 | 27 | 1.35 | 1.60 | 17.00 | 832 | 0.524 | 0.55 | |
Aluminum alloy conductor (IEC standard) | |||||||||||
2X10 | 7 | 1.35 | 1.55 | 23 | 1.13 | 1.40 | 12.41 | 192 | 3.08 | 1.335 | |
2X16 | 7 | 1.70 | 1.55 | 26 | 1.13 | 1.40 | 13.46 | 230 | 1.91 | 1.808 | |
2X25 | 7 | 2.14 | 1.6 | 29 | 1.13 | 1.50 | 15.08 | 290 | 1.20 | 1.0586 | |
2X35 | 19 | 1.53 | 1.65 | 27 | 1.35 | 1.60 | 17.05 | 370 | 0.868 | 0.7966 |
Similar Or Related
Concentric XLPE Solid Aluminum Cable 16mm2 with 4X0.5mm2 Pilot Cores 600/1000V for 33kV Distribution Line
Read More
Concentric XLPE Solid Aluminum Cable 10mm2 with 2X0.5mm2 Pilot Cores 600/1000V for 33kV Distribution Line
Read More
2X10mm2 Hard Drawn Copper Conductor XLPE Insulated Concentric Cable without Pilot Core 0.6/1kV
Read More