Coal Mining Movable Shield Elastic Rubber Sheathed Flexible Cable

Coal Mining Movable Shield Elastic Rubber Sheathed Flexible Cable
Underground
Low and Medium Voltage Cable
AC Cable
Rubber
Rubber
Round Wire
Bare Copper Wire
ISO, CCC, CE
Jinshui
JINHSUI CABLE
REEL
CE, SGS, CCC, ISO
ZHENGZHOU CABLE

Product Description


Coal mining movable shield elastic rubber sheathed flexible cable

Executive standard:
GB12972.5-91 MT818.5-1999

Appliance:
It is suitable for flexible copper-core rubber insulated cable at rated voltage 0.66/1.44KV and below use in movable mining equipment

Operating characteristics:
1,Rated voltage Uo/U 0.38/0.66KV and 0.66/1.44KV
2,Long-term operating temperature of conductor is 65°C.
3,The min. bevelling radius should be 6 times of cable outer diameter

Structure of cable:

Type Description Application
UY MY-0.38/0.66 Coal mining movable rubber sheathed flexible cable Connected power for all kinds of movable coal mining equipment rated voltage upto 0.38/0.66KV
UYE MYE-0.38/0.66 Coal mining movable elastic flexible cable Connected power for all kinds of movable coal mining equipment rated voltage upto 0.38/0.66KV
UYP MYP-0.38/0.66 Coal mining movable shield rubber sheathed flexible cable Connected power for all kinds of movable coal mining equipment rated voltage upto 0.38/0.66KV
UYPE MYPE-0.38/0.66 Coal mining movable shield elastic rubber sheathed flexible cable Connected power for all kinds of movable coal mining equipment rated voltage upto 0.38/0.66KV
UYP MYP 0.66/1.14 Coal mining movable shield rubber sheathed flexible cable Connected power for all kinds of movable coal mining equipment rated voltage upto 0.66/1.14KV
UYPE MYPE 0.66/1.14 Coal mining movable shield elastic rubber sheathed flexible cable Connected power for all kinds of movable coal mining equipment rated voltage upto 0.66/1.14KV

Specification/ Movable coal mining flexible cable

NO.×Nominal cross-section of conductor mm2 Nominal Thickness mm Outer diameter of cable mm NO.×Nominal cross-section of conductor mm2 Nominal Thickness mm Outer diameter of cable mm
insulation sheath UY MY-0.38/0.66
UYE MYE-0.38/0.66
insulation sheath UY MY-0.38/0.66
UYE MYE-0.38/0.66
1×50 1.6 2.4 18.7-20.5 1×185 2.2 3.4 32.7-35.9
1×70 1.6 2.6 20.9-23.0 1×240 2.4 3.5 35.3-38.8
1×95 1.8 2.8 24.2-26.6 1×300 2.6 3.6 40.0-43.3
1×120 1.8 3.0 26.4-29.0 1×400 2.8 3.8 43.4-47.7
1×150 2.0 3.2 30.1-33.1

NO.×Nominal cross-section of conductor mm2 Nominal Thickness mm Outer diameter of cable mm
Power core Earthing core Power core insulation sheath UY MY-0.38/0.66
UYE MYE-0.38/0.66
UYP MYP-0.38/0.66
UYPE MYPE-0.38/0.66
3×4 1×4 1.4 3.5 20.9-23.0 22.9-25.2
3×6 1×6 1.4 3.5 22.9-25.1 24.7-27.2
3×10 1×10 1.6 4.0 27.8-30.6 29.7-32.7
3×16 1×10 1.6 4.0 30.3-33.3 32.2-35.4
3×25 1×16 1.8 4.5 36.4-40.1 38.3-41.0
3×35 1×16 1.8 4.5 40.5-44.5 42.4-46.6
3×50 1×16 2.0 5.0 45.5-50.1 47.4-51.0
3×70 1×25 2.0 5.0 51.5-55.1 52.4-57.1

NO.×Nominal cross-section of conductor mm2 Nominal Thickness mm Outer diameter of cable mm
Power core Earthing core Power core insulation sheath UYP MYP-0.66/1.14
UYPE MYPE-0.66/1.14
3×10 1×10 1.8 4.5 31.7-34.9
3×16 1×10 1.8 4.5 34.2-37.6
3×25 1×16 2.0 5.0 40.3-44.3
3×35 1×16 2.0 5.0 44.4-48.8
3×50 1×16 2.2 5.5 51.5-54.6
3×70 1×25 2.2 5.5 53.9-59.3
3×95 1×25 2.4 6.0 62.1-68.1

Tags: , ,