BS 6622 Single Core Unarmoured (Copper Wire Screen) 15kv XLPE Stranded Copper Conductors
More product about 15kv CableProduct Description
BS 6622 Single Core Unarmoured (Copper Wire Screen) 15KV XLPE Stranded Copper Conductors
Construction
cross-sectional area mmsq |
Minimum average thickness of insulation mm |
Nominal area of copper tape screen |
Nominal area of copper wire screen mm sq |
Nominal thickness of PVC oversheath mm |
Nominal overall diameter of cable mm |
50 |
4.5 |
19.4 |
16 |
1.7 |
26.3 |
70 |
4.5 |
21.2 |
16 |
1.8 |
28.1 |
95 |
4.5 |
22.9 |
16 |
1.9 |
30.1 |
120 |
4.5 |
24.4 |
16 |
1.9 |
31.8 |
150 |
4.5 |
25.7 |
16 |
2 |
33.1 |
185 |
4.5 |
27.5 |
16 |
2 |
35.1 |
240 |
4.5 |
29.7 |
25 |
2.1 |
37.3 |
300 |
4.5 |
32.0 |
25 |
2.2 |
39.8 |
400 |
4.5 |
34.7 |
35 |
2.3 |
42.7 |
500 |
4.5 |
37.6 |
35 |
2.4 |
45.9 |
630 |
4.5 |
41.0 |
35 |
2.5 |
49.5 |
800 |
Please refer to our technical department for further information |
||||
1000 |
Installation
cross-sectional area mmsq |
Approximate cable weight kg/m |
Nominal drum length |
Minimum bending radius mm |
Nominal internal diameter of ducts mm |
50 |
1.1 |
1000 |
500 |
100 |
70 |
1.4 |
1000 |
550 |
100 |
95 |
1.6 |
500 |
550 |
100 |
120 |
1.9 |
500 |
600 |
100 |
150 |
2.2 |
500 |
600 |
100 |
185 |
2.6 |
500 |
650 |
100 |
240 |
3.3 |
500 |
700 |
100 |
300 |
3.9 |
500 |
750 |
100 |
400 |
4.8 |
500 |
800 |
100 |
500 |
5.9 |
500 |
850 |
100 |
630 |
7.2 |
300 |
900 |
100 |
800 |
Please refer to our technical department for further information |
|||
1000 |
Electrical Performance
cross-sectional area mmsq |
Maximum DC resistance of conductor at 20 ºC uohms/m |
Maximum AC resistance of conductor at 90 ºC uohms/m |
Reactance at 50Hz |
Impedance at 50Hz uohms/m |
Maximum Capacitace PF/m |
Maximum charging current at normal voltage and frequency mA/m |
50 |
387 |
494 |
135 |
511 |
204 |
0.56 |
70 |
268 |
343 |
127 |
365 |
232 |
0.63 |
95 |
193 |
248 |
120 |
275 |
258 |
0.7 |
120 |
153 |
196 |
116 |
228 |
281 |
0.77 |
150 |
124 |
159 |
112 |
194 |
301 |
0.82 |
185 |
99.1 |
128 |
109 |
167 |
329 |
0.9 |
240 |
75.4 |
98 |
105 |
143 |
363 |
0.99 |
300 |
60.1 |
80 |
101 |
128 |
398 |
1.09 |
400 |
47 |
64 |
97.9 |
116 |
439 |
1.2 |
500 |
36.6 |
57 |
95.1 |
107 |
483 |
1.32 |
630 |
28.3 |
42 |
91.9 |
101 |
534 |
1.46 |
800 |
Please refer to our technical department for further information |
|||||
1000 |
Ratings
Cross-sectional area |
Current Ratings |
Short circuit ratings |
|||
Laid direct in ground |
Drawn into ducts |
Laid in air |
One second short circuit rating of conductor |
One second short circuit rating of copper per core |
|
50 |
220 |
225 |
250 |
6.8 |
2.6 |
70 |
270 |
270 |
310 |
9.8 |
2.6 |
95 |
320 |
320 |
375 |
13.3 |
2.6 |
120 |
360 |
360 |
430 |
17.2 |
2.6 |
150 |
410 |
400 |
490 |
21.2 |
2.6 |
185 |
460 |
440 |
560 |
26.6 |
2.6 |
240 |
530 |
505 |
660 |
34.9 |
4.3 |
300 |
600 |
560 |
760 |
43.8 |
4.3 |
400 |
680 |
610 |
880 |
57.3 |
5.8 |
500 |
750 |
680 |
1000 |
72.3 |
5.8 |
630 |
830 |
750 |
1140 |
91.2 |
5.8 |
800 |
Please refer to our technical department for further information |
||||
1000 |